Refine
Has Fulltext
- no (215) (remove)
Year of publication
Document Type
- Article (206)
- Review (7)
- Doctoral Thesis (1)
- Other (1)
Language
- English (215) (remove)
Is part of the Bibliography
- yes (215) (remove)
Keywords
Institute
Changing functionality of surfaces by directed self-assembly using oligonucleotides - the oligo-tag
(1999)
Operation of a miniature redox hydrogel-based pyruvate sensor in undiluted deoxygenated calf serum
(2000)
Electrochemical immunoassays
(2000)
Conclusions and outlook
(2001)
Determination of phenolic compounds using recombinant tyrosinanse from Streptomyces antibioticus
(2001)
Amperometric biosensor based on a functionalized gold electrode for the detection of antioxidants
(2002)
Enzyme Electrodes
(2003)
Molecular recognition of cocaine by acetylcholinesterases for affinity purification and bio-sensing
(2003)
The progesterone concentration in blood samples can be utilised as a marker for the diagnosis of early pregnancy, endocrinopathy and virilism. Here, we describe a method for progesterone detection and measurement in whole blood samples by a surface sensitive biosensor used in conjunction with an integrated optical grating coupler. This device determines refractive index changes near the biosensor's surface. Hence, biological species bound to a surface layer can be measured in real-time without any label. For the measurements, we have modified the indirect competitive immonoassay principle. The concentration of the progesterone antibody was kept at 1 µg/ml. Progesterone concentration was determined in buffer solution and whole blood in a range between 0.005 and 10 ng/ml. The detection limit was determined to be 3 pM. The relative standard deviation was calculated to be 3.5%.
Electrochemistry of immobilized CuZnSOD and FeSOD and their interaction with superoxide radicals
(2003)
Copper, zinc superoxide dismutase (CuZnSOD) from bovine erythrocytes and iron superoxide dismutase from Escherichia coli (FeSOD) were immobilized on 3-mercaptopropionic acid (MPA)-modified gold electrodes, respectively. The characterization of the SOD electrodes showed a quasi-reversible, electrochemical redox behavior with a formal potential of 47 ñ 4 mV and -154 ñ 5 mV (vs. Ag/AgCl, 1 M KCl) for surface adsorbed CuZnSOD and FeSOD, respectively. The heterogeneous electron transfer rate constants were determined to be about 65 and 35/s, respectively. Covalent fixation of both SODs was also feasible with only slight changes in the formal potential. The interaction of superoxide radicals (O2-) with the SOD electrode was investigated. No catalytic current could be observed. However, due to the fast cyclic reaction of SOD with superoxide, the communication of the protein with the electrode was strongly influenced. The amperometric detection of superoxide radicals is discussed.
Detection of subicomolar concentrations of human matrix metalloproteinase-2 by an optical biosensor
(2004)
We describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3% for five determinations of 1 pM MMP- 2. No significant binding was observed with the structurally related MMP-9. The assay is far more sensitive and faster than commonly used methods for MMP-2 detection. As TIMP-bound MMP-2 is not detected by this method, the assay can be applied for measuring free MMP-2, reflecting the imbalance of free and inhibitor-bound enzyme in various pathological situations. (C) 2004 Elsevier Inc. All rights reserved