This paper describes the principle of a homogeneous indirect fluorescence quenching immunoassay that uses monoclonal antibodies. It is a carrier-free assay system that is performed completely in solution. The assay system was established for the determination of a low molecular weight substance (hapten), the herbicide diuron, used as a model analyte. A fluorescein-monuron conjugate together with a fluorescence-quenching monoclonal anti-fluorescein antibody and an anti-analyte antibody (here an anti-diuron/monuron monoclonal antibody) were used as central components of the assay. The fluorescein-monuron conjugate can be bound either by the anti-fluorescein monoclonal antibody or by the anti-diuron/ monuron monoclonal antibody. Due to steric hindrance, binding of both antibodies to the conjugate was not possible at the same time. By selecting the antibody concentrations appropriately, a dynamic equilibrium can be established that permits the preferential binding of the anti-diuron/monuron antibody to the conjugate, which allows the fluorescein in the conjugate to fluoresce. This equilibrium can be easily altered by adding free analyte (diuron), which competes with the conjugate to bind to the anti-diuron/monuron antibody. A reduction of anti-diuron/monuron antibody binding to the conjugate results in an increase in the binding of the anti-fluorescein antibody, which leads to a decrease in the fluorescence of the conjugate. The fluorescence is therefore a direct indicator of the state of equilibrium of the system and thus also the presence of free unconjugated analyte. The determination of an analyte based on this test principle does not require any washing steps. After the test components are mixed, the dynamic equilibrium is rapidly reached and the results can be obtained in less than 5 min by measuring the fluorescence of the fluorescein. We used this test principle for the determination of diuron, which was demonstrated for concentrations of approximately 5 nM.
Binding or catalysis? Both can be distinguished with a molecularly imprinted polymer (MIP) by the different patterns of heat generation. The catalytically active sites, like in the corresponding enzyme, generate a steady-state temperature increase. Thus, enzyme-like catalysis and antibody-analogue binding are analyzed simultaneously in a bifunctional MIP for the first time (see scheme).
Affinity interaction betwen phenylboronic acid-carrying self-assembled monolayers and FAD or HRP
(2005)
A method is provided for the recognition of glycated molecules based on their binding affinities to boronate- carrying monolayers. The affinity interaction of flavin adenine dinucleotide (FAD) and horseradish peroxidase (HRP) with phenylboronic acid monolayers on gold was investigated by using voltammetric and microgravimetric methods. Conjugates of 3-aminopherrylboronic acid and 3,3'-dithiodipropionic acid di(N-hydroxysuccinimide ester) or 11-mercaptoundecanoic acid were prepared and self-assembled on gold surfaces to generate monolayers. FAD is bound to this modified sur-face and recognized by a pair of redox peaks with a formal potential of -0.433 V in a 0.1 m phosphate buffer solution, pH 6.5. Upon addition of a sugar to the buffer, the bound FAD could be replaced, indicating that the binding is reversible. Voltammetric, mass measurements, and photometric activity assays show that the HRP can also be bound to the interface. This binding is reversible, and HRP can be replaced by sorbitol or removed in acidic solution. The effects of pH, incubation time, and concentration of H2O2 were studied by comparing the catalytic reduction of H2O2 in the presence of the electron-donor thionine. The catalytic current of the HRP-loaded electrode was proportional to HRP concentrations in the incubation solution in the range between 5 mu g mL(-1) and 0.4 mg mL(-1) with a linear slope of 3.34 mu A mL mg(-1) and a correlation coefficient of 0.9945
Electrochemical bioassay utilizing encapsulated electrochemical active microcrystal biolabels
(2005)
A new approach to perform electrochemical immunoassay based on the utilization of encapsulated microcrystal was developed. The microcrystal labels create a "supernova effect" upon exposure to a desired releasing agent. The microcrystal cores dissolve, and large amounts of signal-generating molecules diffuse across the capsule wall into the outer environment. Layer-by-Layer (LbL) technology was employed for the encapsulation of electrochemical signal- generating microcrystals (ferrocene microcrystals). The encapsulated microcrystals were conjugated with antibody molecules through the adsorption process. The biofunctionalized microcrystals were utilized as a probe for immunoassays. The microcrystal-based label system provided a high-signal molecule to antibody (SIP) ratio of 10(4)-10(5). Microcrystal biolabels with different antibody surface coverage (1.60-5.05 mg m(-2)) were subjected to a solid-phase immunoassay for the detection of mouse immunoglobulin G (M-IgG) molecules. The microcrystal-based immunoassay for the detection of M-IgG performed with microcrystals having antibody surface coverage of 5.05 mg m(-2) showed a sensitivity of 3.93 nA g(- 1) L-1 with a detection limit of 2.82 g L-1
Biosensorik / Bioanalytik
(2004)
In this work we describe a new preparation method for an esterolytic imprinted polymer with catalytic sites on the surface. A template was prepared by immobilizing a transition state analogue (phosphoramidic acid derivative) of an esterolytic reaction within porous silica particles. Polymerization within the pores was carried out using 4- vinylimidazole as a functional monomer and divinylbenzene as a cross-linker. The polymer was released by dissolution of the silica support with hydrofluoric acid and catalytic properties were studied by incubation with three different 4- nitrophenylesters and spectrophotometric determination of the released 4-nitrophenol. For 4-nitrophenyl acetate an activity of 211 nmol min(-1) mg(-1) and a K-m value of 2.2 mmol L-1 was obtained