• search hit 9 of 57305
Back to Result List

Deep learning reconstruction improves radiomics feature stability and discriminative power in abdominal CT imaging

  • Objectives To compare image quality of deep learning reconstruction (AiCE) for radiomics feature extraction with filtered back projection (FBP), hybrid iterative reconstruction (AIDR 3D), and model-based iterative reconstruction (FIRST). Methods Effects of image reconstruction on radiomics features were investigated using a phantom that realistically mimicked a 65-year-old patient's abdomen with hepatic metastases. The phantom was scanned at 18 doses from 0.2 to 4 mGy, with 20 repeated scans per dose. Images were reconstructed with FBP, AIDR 3D, FIRST, and AiCE. Ninety-three radiomics features were extracted from 24 regions of interest, which were evenly distributed across three tissue classes: normal liver, metastatic core, and metastatic rim. Features were analyzed in terms of their consistent characterization of tissues within the same image (intraclass correlation coefficient >= 0.75), discriminative power (Kruskal-Wallis test p value < 0.05), and repeatability (overall concordance correlation coefficient >= 0.75). Results TheObjectives To compare image quality of deep learning reconstruction (AiCE) for radiomics feature extraction with filtered back projection (FBP), hybrid iterative reconstruction (AIDR 3D), and model-based iterative reconstruction (FIRST). Methods Effects of image reconstruction on radiomics features were investigated using a phantom that realistically mimicked a 65-year-old patient's abdomen with hepatic metastases. The phantom was scanned at 18 doses from 0.2 to 4 mGy, with 20 repeated scans per dose. Images were reconstructed with FBP, AIDR 3D, FIRST, and AiCE. Ninety-three radiomics features were extracted from 24 regions of interest, which were evenly distributed across three tissue classes: normal liver, metastatic core, and metastatic rim. Features were analyzed in terms of their consistent characterization of tissues within the same image (intraclass correlation coefficient >= 0.75), discriminative power (Kruskal-Wallis test p value < 0.05), and repeatability (overall concordance correlation coefficient >= 0.75). Results The median fraction of consistent features across all doses was 6%, 8%, 6%, and 22% with FBP, AIDR 3D, FIRST, and AiCE, respectively. Adequate discriminative power was achieved by 48%, 82%, 84%, and 92% of features, and 52%, 20%, 17%, and 39% of features were repeatable, respectively. Only 5% of features combined consistency, discriminative power, and repeatability with FBP, AIDR 3D, and FIRST versus 13% with AiCE at doses above 1 mGy and 17% at doses >= 3 mGy. AiCE was the only reconstruction technique that enabled extraction of higher-order features. Conclusions AiCE more than doubled the yield of radiomics features at doses typically used clinically. Inconsistent tissue characterization within CT images contributes significantly to the poor stability of radiomics features.show moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:Florian Michallek, Ulrich GenskeORCiD, Stefan Markus Niehues, Bernd Hamm, Paul JahnkeORCiD
DOI:https://doi.org/10.1007/s00330-022-08592-y
ISSN:0938-7994
ISSN:1432-1084
Pubmed ID:https://pubmed.ncbi.nlm.nih.gov/35174400
Title of parent work (English):European Radiology
Subtitle (English):a phantom study
Publisher:Springer
Place of publishing:New York
Publication type:Article
Language:English
Date of first publication:2022/02/16
Publication year:2022
Release date:2024/05/27
Tag:Algorithms; Liver neoplasms; Phantoms; Reproducibility of results; Tomography; X-ray computed; imaging
Volume:32
Issue:7
Number of pages:9
First page:4587
Last Page:4595
Funding institution:Projekt DEAL; Bundesministerium fur Wirtschaft und Energie (DE); [03EFHBE093]
Organizational units:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Informatik und Computational Science
DDC classification:0 Informatik, Informationswissenschaft, allgemeine Werke / 00 Informatik, Wissen, Systeme / 000 Informatik, Informationswissenschaft, allgemeine Werke
Peer review:Referiert
Publishing method:Open Access / Hybrid Open-Access
License (German):License LogoCC-BY - Namensnennung 4.0 International