- Chronic obstructive pulmonary disease (COPD) (1)
- Hapten (1)
- Immunosensor (1)
- Leukotriene B4 (1)
- Monoclonal antibody (1)
Institute
A novel electrochemical immunoassay based on the multiple affinity labeling of the indicator antibody with an electro-active tag is presented. The concept is illustrated for the determination of the glycated hemoglobin HbA1c in hemoglobin samples. Hemoglobin is adsorbed to the surfactant-modified surface of a piezoelectric quartz crystal. Whereas the quartz crystal nanobalance is used to validate the total Hb binding, the HbA1c on the sensor surface is recognized by an antibody and quantified electrochemically after the sugar moieties of the antibody have been labeled in-situ with ferroceneboronic acid. The sensitivity of this sensor is about threefold higher than the sensitivity of a hemoglobin sensor, where the ferroceneboronic acid is bound directly to HbA1c.
This paper describes the principle of a homogeneous indirect fluorescence quenching immunoassay that uses monoclonal antibodies. It is a carrier-free assay system that is performed completely in solution. The assay system was established for the determination of a low molecular weight substance (hapten), the herbicide diuron, used as a model analyte. A fluorescein-monuron conjugate together with a fluorescence-quenching monoclonal anti-fluorescein antibody and an anti-analyte antibody (here an anti-diuron/monuron monoclonal antibody) were used as central components of the assay. The fluorescein-monuron conjugate can be bound either by the anti-fluorescein monoclonal antibody or by the anti-diuron/ monuron monoclonal antibody. Due to steric hindrance, binding of both antibodies to the conjugate was not possible at the same time. By selecting the antibody concentrations appropriately, a dynamic equilibrium can be established that permits the preferential binding of the anti-diuron/monuron antibody to the conjugate, which allows the fluorescein in the conjugate to fluoresce. This equilibrium can be easily altered by adding free analyte (diuron), which competes with the conjugate to bind to the anti-diuron/monuron antibody. A reduction of anti-diuron/monuron antibody binding to the conjugate results in an increase in the binding of the anti-fluorescein antibody, which leads to a decrease in the fluorescence of the conjugate. The fluorescence is therefore a direct indicator of the state of equilibrium of the system and thus also the presence of free unconjugated analyte. The determination of an analyte based on this test principle does not require any washing steps. After the test components are mixed, the dynamic equilibrium is rapidly reached and the results can be obtained in less than 5 min by measuring the fluorescence of the fluorescein. We used this test principle for the determination of diuron, which was demonstrated for concentrations of approximately 5 nM.
Point-of-care testing (POCT) is a fast developing area in clinical diagnostics that is considered to be one of the main driving forces for the future in vitro diagnostic market. POCT means decentralized testing at the site of patient care. The most important POCT devices are handheld blood glucose sensors. In some of these sensors, after the application of less than 1 A mu l whole blood, the results are displayed in less than 10 s. For protein determination, the most commonly used devices are based on lateral flow technology. Although these devices are convenient to use, the results are often only qualitative or semiquantitative. The review will illuminate some of the current methods employed in POCT for proteins and will discuss the outlook for techniques (e.g., electrochemical immunosensors) that could have a great impact on future POCT of proteins.
This work describes a method for surface regeneration of microfluidic microarray printheads through plasma techniques. Modification procedures were chosen in a way to obtain high reproducibility with a minimum of time consumption. The idea behind this is a complete regeneration of a microarray printhead before or after usage to achieve best printing results over a typical print job. A sequence of low-pressure oxygen-plasma and plasma polymerization with hexamethyldisiloxane (HMDSO) was used to regenerate printheads. Proof of the concept is given through quality control performed with a spotter implemented CCD camera, contact angle measurements and a typical hybridization experiment. Stable printing results were obtained over 3000 activations showing that the presented method is suitable for treatment of microarray printheads.
In this work we present a CMOS high frequency direct immunosensor operating at 6 GHz (C-band) for label free determination of creatinine. The sensor is fabricated in standard 0.13 mu m SiGe:C BiCMOS process. The report also demonstrates the ability to immobilize creatinine molecules on a Si3N4 passivation layer of the standard BiCMOS/CMOS process, therefore, evading any further need of cumbersome post processing of the fabricated sensor chip. The sensor is based on capacitive detection of the amount of non-creatinine bound antibodies binding to an immobilized creatinine layer on the passivated sensor. The chip bound antibody amount in turn corresponds indirectly to the creatinine concentration used in the incubation phase. The determination of creatinine in the concentration range of 0.88-880 mu M is successfully demonstrated in this work. A sensitivity of 35 MHz/10 fold increase in creatinine concentration (during incubation) at the centre frequency of 6 GHz is gained by the immunosensor. The results are compared with a standard optical measurement technique and the dynamic range and sensitivity is of the order of the established optical indication technique. The C-band immunosensor chip comprising an area of 0.3 mm(2) reduces the sensing area considerably, therefore, requiring a sample volume as low as 2 mu l. The small analyte sample volume and label free approach also reduce the experimental costs in addition to the low fabrication costs offered by the batch fabrication technique of CMOS/BiCMOS process.
Leukotriene B4 as an inflammatory mediator is an important biomarker for different respiratory diseases like asthma, chronic obstructive pulmonary disease or cystic lung fibrosis. Therefore the detection of LTB4 is helpful in the diagnosis of these pulmonary diseases. However, until now its determination in exhaled breath condensates suffers from problems of accuracy. Reasons for that could be improper sample collection and preparation methods of condensates and the lack of consistently assay specificity and reproducibility of the used immunoassay detection system. In this study we describe the development and the characterization of a specific monoclonal antibody (S27BC6) against LTB4, its use as molecular recognition element for the development of an enzyme-linked immunoassay to detect LTB4 and discuss possible future diagnostic applications.