Refine
Has Fulltext
- no (215) (remove)
Year of publication
Document Type
- Article (206)
- Review (7)
- Doctoral Thesis (1)
- Other (1)
Language
- English (215) (remove)
Is part of the Bibliography
- yes (215) (remove)
Keywords
Institute
Glucose dehydrogenase (GDH) was assembled electrostatically onto QCM-gold electrodes by their sequential deposition with anionic polyelectrolytes such as PSS and PASA. For the layer-by-layer arrangements both the microgravimetric and the electrochemical sensor signal were followed. Increasing amounts of GDH were deposited by stepwise formation of alternating layers of GDH and PSS or PASA. The mass increase was about 1.88 mug/cm(2) for one GDH/ PASA bilayer and 2.4 mug/cm(2) for a GDH/PSS bilayer. The addition of phenolic compounds resulted in an oxidation current, which could be catalytically increased by the GDH catalysed reaction in the presence of glucose. The system functions as glucose sensor when quinones are present in nonlimiting amount. The amperometric response was already diffusion limited when a single layer of GDH was adsorbed. The sensor sensitivity increased by a factor of 10 when MSA was used instead of MUA as initial electrode modifier
A tailor-made horseradish peroxidase (HRP) bulk composite electrode was developed on the basis of pyrolyzed cobalt tetramethoxyphenylporphyrin (CoTMPP) by modifying pore size and surface area of the porous carbon material through varying amounts of iron oxalate and sulfur prior to pyrolyzation. The materials were used to immobilize horseradish peroxidase (HRP). These electrodes were characterized in terms of their efficiency to reduce hydrogen peroxide. The heterogeneous electron transfer rate constants of different materials were determined with the rotating disk electrode method and a k(S) (401 +/- 61 s(-1)) exceeding previously reported values for native HRP was found.
An amperometric biosensor for the determination of glycated hemoglobin in human whole blood is proposed. The principle is based on the electrochemical measurement of ferroceneboronic acid (FcBA) that has been specifically bound to the glycated N-terminus. Hemoglobin is immobilized on a zirconium dioxide nanoparticle modified pyrolytic graphite electrode (PGE) in the presence of didodecyldimethylammonium bromide (DDAB). The incubation of this sensor in FcBA solution leads to the formation of an FcBA-modified surface due to the affinity interaction between boronate and the glycated sites of the hemoglobin. The binding of FcBA results in well-defined redox peaks with an E-0' of 0.299 V versus Ag/AgCl (1 M KCl). The square wave voltammetric response of the bound FcBA reflects the amount of glycated hemoglobin at the surface. This signal increases linearily with the degree of glycated hemoglobin from 6.8 to 14.0% of total immobilized hemoglobin. The scheme was applied to the determination of the fraction of glycated hemoglobin in whole blood samples.
Affinity interaction betwen phenylboronic acid-carrying self-assembled monolayers and FAD or HRP
(2005)
A method is provided for the recognition of glycated molecules based on their binding affinities to boronate- carrying monolayers. The affinity interaction of flavin adenine dinucleotide (FAD) and horseradish peroxidase (HRP) with phenylboronic acid monolayers on gold was investigated by using voltammetric and microgravimetric methods. Conjugates of 3-aminopherrylboronic acid and 3,3'-dithiodipropionic acid di(N-hydroxysuccinimide ester) or 11-mercaptoundecanoic acid were prepared and self-assembled on gold surfaces to generate monolayers. FAD is bound to this modified sur-face and recognized by a pair of redox peaks with a formal potential of -0.433 V in a 0.1 m phosphate buffer solution, pH 6.5. Upon addition of a sugar to the buffer, the bound FAD could be replaced, indicating that the binding is reversible. Voltammetric, mass measurements, and photometric activity assays show that the HRP can also be bound to the interface. This binding is reversible, and HRP can be replaced by sorbitol or removed in acidic solution. The effects of pH, incubation time, and concentration of H2O2 were studied by comparing the catalytic reduction of H2O2 in the presence of the electron-donor thionine. The catalytic current of the HRP-loaded electrode was proportional to HRP concentrations in the incubation solution in the range between 5 mu g mL(-1) and 0.4 mg mL(-1) with a linear slope of 3.34 mu A mL mg(-1) and a correlation coefficient of 0.9945