Refine
Has Fulltext
- no (8) (remove)
Document Type
- Article (8)
Is part of the Bibliography
- yes (8)
Keywords
- bank filtration (2)
- Baltic Sea (1)
- COSMOS rover (1)
- Environmental sciences (1)
- Küstenniederung (1)
- Optics and photonics (1)
- Ostsee (1)
- Plant sciences (1)
- Prozessgeschehen (1)
- Sturmhochwasser (1)
Institute
- Institut für Umweltwissenschaften und Geographie (8) (remove)
Bank filtration (BF) is an established indirect water-treatment technology. The quality of water gained via BF depends on the subsurface capture zone, the mixing ratio (river water versus ambient groundwater), spatial and temporal distribution of subsurface travel times, and subsurface temperature patterns. Surface-water infiltration into the adjacent aquifer is determined by the local hydraulic gradient and riverbed permeability, which could be altered by natural clogging, scouring and artificial decolmation processes. The seasonal behaviour of a BF system in Germany, and its development during and about 6 months after decolmation (canal reconstruction), was observed with a long-term monitoring programme. To quantify the spatial and temporal variation in the BF system, a transient flow and heat transport model was implemented and two model scenarios, 'with' and 'without' canal reconstruction, were generated. Overall, the simulated water heads and temperatures matched those observed. Increased hydraulic connection between the canal and aquifer caused by the canal reconstruction led to an increase of similar to 23% in the already high share of BF water abstracted by the nearby waterworks. Subsurface travel-time distribution substantially shifted towards shorter travel times. Flow paths with travel times <200 days increased by similar to 10% and those with <300 days by 15%. Generally, the periodic temperature signal, and the summer and winter temperature extrema, increased and penetrated deeper into the aquifer. The joint hydrological and thermal effects caused by the canal reconstruction might increase the potential of biodegradable compounds to further penetrate into the aquifer, also by potentially affecting the redox zonation in the aquifer.
Root water uptake is an essential process for terrestrial plants that strongly affects the spatiotemporal distribution of water in vegetated soil. Fast neutron tomography is a recently established non-invasive imaging technique capable to capture the 3D architecture of root systems in situ and even allows for tracking of three-dimensional water flow in soil and roots. We present an in vivo analysis of local water uptake and transport by roots of soil-grown maize plants—for the first time measured in a three-dimensional time-resolved manner. Using deuterated water as tracer in infiltration experiments, we visualized soil imbibition, local root uptake, and tracked the transport of deuterated water throughout the fibrous root system for a day and night situation. This revealed significant differences in water transport between different root types. The primary root was the preferred water transport path in the 13-days-old plants while seminal roots of comparable size and length contributed little to plant water supply. The results underline the unique potential of fast neutron tomography to provide time-resolved 3D in vivo information on the water uptake and transport dynamics of plant root systems, thus contributing to a better understanding of the complex interactions of plant, soil and water.
Measurements of root-zone soil moisture across spatial scales of tens to thousands of meters have been a challenge for many decades. The mobile application of Cosmic Ray Neutron Sensing (CRNS) is a promising approach to measure field soil moisture noninvasively by surveying large regions with a ground-based vehicle. Recently, concerns have been raised about a potentially biasing influence of local structures and roads. We employed neutron transport simulations and dedicated experiments to quantify the influence of different road types on the CRNS measurement. We found that roads introduce a substantial bias in the CRNS estimation of field soil moisture compared to off-road scenarios. However, this effect becomes insignificant at distances beyond a few meters from the road. Neutron measurements on the road could overestimate the field value by up to 40 % depending on road material, width, and the surrounding field water content. The bias could be largely removed with an analytical correction function that accounts for these parameters. Additionally, an empirical approach is proposed that can be used without prior knowledge of field soil moisture. Tests at different study sites demonstrated good agreement between road-effect corrected measurements and field soil moisture observations. However, if knowledge about the road characteristics is missing, measurements on the road could substantially reduce the accuracy of this method. Our results constitute a practical advancement of the mobile CRNS methodology, which is important for providing unbiased estimates of field-scale soil moisture to support applications in hydrology, remote sensing, and agriculture. Plain Language Summary Measurements of root-zone soil moisture across spatial scales of tens to thousands of meters have been a challenge for many decades. The mobile application of Cosmic Ray Neutron Sensing (CRNS) is a promising approach to measure field soil moisture noninvasively by surveying large regions with a ground-based vehicle. Recently, concerns have been raised about a potentially biasing influence of roads. We employed physics simulations and dedicated experiments to quantify the influence of different road types on the CRNS measurement. We found that the presence of roads biased the CRNS estimation of field soil moisture compared to nonroad scenarios. Neutron measurements could overestimate the field value by up to 40 % depending on road material, width, surrounding field water content, and distance from the road. We proposed a correction function that successfully removed this bias and works even without prior knowledge of field soil moisture. Tests at different study sites demonstrated good agreement between corrected measurements and other field soil moisture observations. Our results constitute a practical advancement of the mobile CRNS methodology, which is important for providing unbiased estimates of field-scale soil moisture to support applications in hydrology, remote sensing, and agriculture.
Entlang der Küstenniederung des Naturschutzgebietes „Hütelmoor und Heiligensee“, ca. 6 km nordöstlich von Rostock-Warnemünde gelegen, wird seit dem Jahr 2000 die Küstendüne nicht mehr instand gehalten. Im Rahmen der Renaturierung des Gebietes werden so grundsätzlich wieder Überflutungen bei Ostseehochwassern zugelassen, was bisher jedoch noch nicht eingetreten ist. Am 4./5. Januar 2017 ereignete sich ein Sturmhochwasser der Ostsee, mit einem Scheitelwasserstand in Warnemünde, der sich zwischen dem 10- und 20-jährlichen Hochwasserstand einordnet. Dennoch kam es bei diesem Ereignis nicht zum Dünendurchbruch und zur seeseitigen Überflutung, wohl aber zum binnenseitigen Einstrom von Salz- bzw. Brackwasser. Dieser erfolgte über den Graben, durch den das Gebiet normalerweise über die Warnow in die Ostsee entwässert. Durch das Einströmen über die Sohlschwelle, sonst Auslass des Gebietes, stiegen die Wasserstände und Salzkonzentrationen in der südwestlichen Hälfte der Niederung an. Mit zunehmender Entfernung zur Sohlschwelle waren diese Auswirkungen jedoch geringer spürbar. Dies gilt wegen der Retentionswirkung der Niederung mehr für den Wasserstand als für die Salzkonzentration. Während der Wasserstand durch den Einstau der Niederung und Überschwemmungen flächenhaft anstieg, breitete sich die Salzfront präferentiell in den ehemaligen Entwässerungsgräben, die trotz des Einstaus nach wie vor hydraulisch aktiv sind, eher linienhaft aus. Diese Interpretation beruht auf Messergebnissen von Wasserstand, elektrischer Leitfähigkeit und Wassertemperatur.
Cosmic-ray neutron sensing (CRNS) is a powerful technique for retrieving representative estimates of soil water content at a horizontal scale of hectometres (the “field scale”) and depths of tens of centimetres (“the root zone”). This study demonstrates the potential of the CRNS technique to obtain spatio-temporal patterns of soil moisture beyond the integrated volume from isolated CRNS footprints. We use data from an observational campaign carried out between May and July 2019 that featured a dense network of more than 20 neutron detectors with partly overlapping footprints in an area that exhibits pronounced soil moisture gradients within one square kilometre. The present study is the first to combine these observations in order to represent the heterogeneity of soil water content at the sub-footprint scale as well as between the CRNS stations. First, we apply a state-of-the-art procedure to correct the observed neutron count rates for static effects (heterogeneity in space, e.g. soil organic matter) and dynamic effects (heterogeneity in time, e.g. barometric pressure). Based on the homogenized neutron data, we investigate the robustness of a calibration approach that uses a single calibration parameter across all CRNS stations. Finally, we benchmark two different interpolation techniques for obtaining spatio-temporal representations of soil moisture: first, ordinary Kriging with a fixed range; second, spatial interpolation complemented by geophysical inversion (“constrained interpolation”). To that end, we optimize the parameters of a geostatistical interpolation model so that the error in the forward-simulated neutron count rates is minimized, and suggest a heuristic forward operator to make the optimization problem computationally feasible. Comparison with independent measurements from a cluster of soil moisture sensors (SoilNet) shows that the constrained interpolation approach is superior for representing horizontal soil moisture gradients at the hectometre scale. The study demonstrates how a CRNS network can be used to generate coherent, consistent, and continuous soil moisture patterns that could be used to validate hydrological models or remote sensing products.
Core Ideas
3D MRI relaxation time maps reflect water mobility in root, rhizosphere, and soil.
3D NCT water content maps of the same plant complement relaxation time maps.
The relaxation time T1 decreases from soil to root, whereas water content increases.
Parameters together indicate modification of rhizosphere pore space by gel phase.
The zone of reduced T1 corresponds to the zone remaining dry after rewetting.
In situ investigations of the rhizosphere require high‐resolution imaging techniques, which allow a look into the optically opaque soil compartment. We present the novel combination of magnetic resonance imaging (MRI) and neutron computed tomography (NCT) to achieve synergistic information such as water mobility in terms of three‐dimensional (3D) relaxation time maps and total water content maps. Besides a stationary MRI scanner for relaxation time mapping, we used a transportable MRI system on site in the NCT facility to capture rhizosphere properties before desiccation and after subsequent rewetting. First, we addressed two questions using water‐filled test capillaries between 0.1 and 5 mm: which root diameters can still be detected by both methods, and to what extent are defined interfaces blurred by these imaging techniques? Going to real root system architecture, we demonstrated the sensitivity of the transportable MRI device by co‐registration with NCT and additional validation using X‐ray computed tomography. Under saturated conditions, we observed for the rhizosphere in situ a zone with shorter T1 relaxation time across a distance of about 1 mm that was not caused by reduced water content, as proven by successive NCT measurements. We conclude that the effective pore size in the pore network had changed, induced by a gel phase. After rewetting, NCT images showed a dry zone persisting while the MRI intensity inside the root increased considerably, indicating water uptake from the surrounding bulk soil through the still hydrophobic rhizosphere. Overall, combining NCT and MRI allows a more detailed analysis of the rhizosphere's functioning.
Cosmic-ray neutron sensing (CRNS) is a non-invasive tool for measuring hydrogen pools such as soil moisture, snow or vegetation. The intrinsic integration over a radial hectare-scale footprint is a clear advantage for averaging out small-scale heterogeneity, but on the other hand the data may become hard to interpret in complex terrain with patchy land use.
This study presents a directional shielding approach to prevent neutrons from certain angles from being counted while counting neutrons entering the detector from other angles and explores its potential to gain a sharper horizontal view on the surrounding soil moisture distribution.
Using the Monte Carlo code URANOS (Ultra Rapid Neutron-Only Simulation), we modelled the effect of additional polyethylene shields on the horizontal field of view and assessed its impact on the epithermal count rate, propagated uncertainties and aggregation time.
The results demonstrate that directional CRNS measurements are strongly dominated by isotropic neutron transport, which dilutes the signal of the targeted direction especially from the far field. For typical count rates of customary CRNS stations, directional shielding of half-spaces could not lead to acceptable precision at a daily time resolution. However, the mere statistical distinction of two rates should be feasible.
Bank filtration is considered to improve water quality through microbially mediated degradation of pollutants and is suitable for waterworks to increase their production. In particular, aquifer temperatures and oxygen supply have a great impact on many microbial processes. To investigate the temporal and spatial behavior of selected organic micropollutants during bank filtration in dependence of relevant biogeochemical conditions, we have set up a 2D reactive transport model using MODFLOW and PHT3D under the user interface ORTI3D. The considered 160-m-long transect ranges from the surface water to a groundwater extraction well of the adjacent waterworks. For this purpose, water levels, temperatures, and chemical parameters were regularly measured in the surface water and groundwater observation wells over one and a half years. To simulate the effect of seasonal temperature variations on microbial mediated degradation, we applied an empirical temperature factor, which yields a strong reduction of the degradation rate at groundwater temperatures below 11 degrees C. Except for acesulfame, the considered organic micropollutants are substantially degraded along their subsurface flow paths with maximum degradation rates in the range of 10(-6) mol L-1 s(-1). Preferential biodegradation of phenazone, diclofenac, and valsartan was found under oxic conditions, whereas carbamazepine and sulfamethoxazole were degraded under anoxic conditions. This study highlights the influence of seasonal variations in oxygen supply and temperature on the fate of organic micropollutants in surface water infiltrating into an aquifer.