Refine
Document Type
- Article (3)
- Postprint (3)
- Doctoral Thesis (1)
Language
- English (7)
Is part of the Bibliography
- yes (7)
Keywords
- calibration (7) (remove)
Temporal variation of natural light sources such as airglow limits the ability of night light sensors to detect changes in small sources of artificial light (such as villages). This study presents a method for correcting for this effect globally, using the satellite radiance detected from regions without artificial light emissions. We developed a routine to define an approximate grid of locations worldwide that do not have regular light emission. We apply this method with a 5 degree equally spaced global grid (total of 2016 individual locations), using data from the Visible Infrared Imaging Radiometer Suite (VIIRS) Day-Night Band (DNB). This code could easily be adapted for other future global sensors. The correction reduces the standard deviation of data in the Earth Observation Group monthly DNB composites by almost a factor of two. The code and datasets presented here are available under an open license by GFZ Data Services, and are implemented in the Radiance Light Trends web application.
Temporal variation of natural light sources such as airglow limits the ability of night light sensors to detect changes in small sources of artificial light (such as villages). This study presents a method for correcting for this effect globally, using the satellite radiance detected from regions without artificial light emissions. We developed a routine to define an approximate grid of locations worldwide that do not have regular light emission. We apply this method with a 5 degree equally spaced global grid (total of 2016 individual locations), using data from the Visible Infrared Imaging Radiometer Suite (VIIRS) Day-Night Band (DNB). This code could easily be adapted for other future global sensors. The correction reduces the standard deviation of data in the Earth Observation Group monthly DNB composites by almost a factor of two. The code and datasets presented here are available under an open license by GFZ Data Services, and are implemented in the Radiance Light Trends web application.
Accurate weather observations are the keystone to many quantitative applications, such as precipitation monitoring and nowcasting, hydrological modelling and forecasting, climate studies, as well as understanding precipitation-driven natural hazards (i.e. floods, landslides, debris flow). Weather radars have been an increasingly popular tool since the 1940s to provide high spatial and temporal resolution precipitation data at the mesoscale, bridging the gap between synoptic and point scale observations. Yet, many institutions still struggle to tap the potential of the large archives of reflectivity, as there is still much to understand about factors that contribute to measurement errors, one of which is calibration. Calibration represents a substantial source of uncertainty in quantitative precipitation estimation (QPE). A miscalibration of a few dBZ can easily deteriorate the accuracy of precipitation estimates by an order of magnitude. Instances where rain cells carrying torrential rains are misidentified by the radar as moderate rain could mean the difference between a timely warning and a devastating flood.
Since 2012, the Philippine Atmospheric, Geophysical, and Astronomical Services Administration (PAGASA) has been expanding the country’s ground radar network. We had a first look into the dataset from one of the longest running radars (the Subic radar) after devastating week-long torrential rains and thunderstorms in August 2012 caused by the annual southwestmonsoon and enhanced by the north-passing Typhoon Haikui. The analysis of the rainfall spatial distribution revealed the added value of radar-based QPE in comparison to interpolated rain gauge observations. However, when compared with local gauge measurements, severe miscalibration of the Subic radar was found. As a consequence, the radar-based QPE would have underestimated the rainfall amount by up to 60% if they had not been adjusted by rain gauge observations—a technique that is not only affected by other uncertainties, but which is also not feasible in other regions of the country with very sparse rain gauge coverage.
Relative calibration techniques, or the assessment of bias from the reflectivity of two radars, has been steadily gaining popularity. Previous studies have demonstrated that reflectivity observations from the Tropical Rainfall Measuring Mission (TRMM) and its successor, the Global Precipitation Measurement (GPM), are accurate enough to serve as a calibration reference for ground radars over low-to-mid-latitudes (± 35 deg for TRMM; ± 65 deg for GPM). Comparing spaceborne radars (SR) and ground radars (GR) requires cautious consideration of differences in measurement geometry and instrument specifications, as well as temporal coincidence. For this purpose, we implement a 3-D volume matching method developed by Schwaller and Morris (2011) and extended by Warren et al. (2018) to 5 years worth of observations from the Subic radar. In this method, only the volumetric intersections of the SR and GR beams are considered.
Calibration bias affects reflectivity observations homogeneously across the entire radar domain. Yet, other sources of systematic measurement errors are highly heterogeneous in space, and can either enhance or balance the bias introduced by miscalibration. In order to account for such heterogeneous errors, and thus isolate the calibration bias, we assign a quality index to each matching SR–GR volume, and thus compute the GR calibration bias as a qualityweighted average of reflectivity differences in any sample of matching SR–GR volumes. We exemplify the idea of quality-weighted averaging by using beam blockage fraction (BBF) as a quality variable. Quality-weighted averaging is able to increase the consistency of SR and GR observations by decreasing the standard deviation of the SR–GR differences, and thus increasing the precision of the bias estimates.
To extend this framework further, the SR–GR quality-weighted bias estimation is applied to the neighboring Tagaytay radar, but this time focusing on path-integrated attenuation (PIA) as the source of uncertainty. Tagaytay is a C-band radar operating at a lower wavelength and is therefore more affected by attenuation. Applying the same method used for the Subic radar, a time series of calibration bias is also established for the Tagaytay radar.
Tagaytay radar sits at a higher altitude than the Subic radar and is surrounded by a gentler terrain, so beam blockage is negligible, especially in the overlapping region. Conversely, Subic radar is largely affected by beam blockage in the overlapping region, but being an SBand radar, attenuation is considered negligible. This coincidentally independent uncertainty contributions of each radar in the region of overlap provides an ideal environment to experiment with the different scenarios of quality filtering when comparing reflectivities from the two ground radars. The standard deviation of the GR–GR differences already decreases if we consider either BBF or PIA to compute the quality index and thus the weights. However, combining them multiplicatively resulted in the largest decrease in standard deviation, suggesting that taking both factors into account increases the consistency between the matched samples.
The overlap between the two radars and the instances of the SR passing over the two radars at the same time allows for verification of the SR–GR quality-weighted bias estimation method. In this regard, the consistency between the two ground radars is analyzed before and after bias correction is applied. For cases when all three radars are coincident during a significant rainfall event, the correction of GR reflectivities with calibration bias estimates from SR overpasses dramatically improves the consistency between the two ground radars which have shown incoherent observations before correction. We also show that for cases where adequate SR coverage is unavailable, interpolating the calibration biases using a moving average can be used to correct the GR observations for any point in time to some extent. By using the interpolated biases to correct GR observations, we demonstrate that bias correction reduces the absolute value of the mean difference in most cases, and therefore improves the consistency between the two ground radars.
This thesis demonstrates that in general, taking into account systematic sources of uncertainty that are heterogeneous in space (e.g. BBF) and time (e.g. PIA) allows for a more consistent estimation of calibration bias, a homogeneous quantity. The bias still exhibits an unexpected variability in time, which hints that there are still other sources of errors that remain unexplored. Nevertheless, the increase in consistency between SR and GR as well as between the two ground radars, suggests that considering BBF and PIA in a weighted-averaging approach is a step in the right direction.
Despite the ample room for improvement, the approach that combines volume matching between radars (either SR–GR or GR–GR) and quality-weighted comparison is readily available for application or further scrutiny. As a step towards reproducibility and transparency in atmospheric science, the 3D matching procedure and the analysis workflows as well as sample data are made available in public repositories. Open-source software such as Python and wradlib are used for all radar data processing in this thesis. This approach towards open science provides both research institutions and weather services with a valuable tool that can be applied to radar calibration, from monitoring to a posteriori correction of archived data.
Cosmic-ray neutron sensing (CRNS) is a non-invasive tool for measuring hydrogen pools such as soil moisture, snow or vegetation. The intrinsic integration over a radial hectare-scale footprint is a clear advantage for averaging out small-scale heterogeneity, but on the other hand the data may become hard to interpret in complex terrain with patchy land use.
This study presents a directional shielding approach to prevent neutrons from certain angles from being counted while counting neutrons entering the detector from other angles and explores its potential to gain a sharper horizontal view on the surrounding soil moisture distribution.
Using the Monte Carlo code URANOS (Ultra Rapid Neutron-Only Simulation), we modelled the effect of additional polyethylene shields on the horizontal field of view and assessed its impact on the epithermal count rate, propagated uncertainties and aggregation time.
The results demonstrate that directional CRNS measurements are strongly dominated by isotropic neutron transport, which dilutes the signal of the targeted direction especially from the far field. For typical count rates of customary CRNS stations, directional shielding of half-spaces could not lead to acceptable precision at a daily time resolution. However, the mere statistical distinction of two rates should be feasible.
Cosmic-ray neutron sensing (CRNS) is a non-invasive tool for measuring hydrogen pools such as soil moisture, snow or vegetation. The intrinsic integration over a radial hectare-scale footprint is a clear advantage for averaging out small-scale heterogeneity, but on the other hand the data may become hard to interpret in complex terrain with patchy land use.
This study presents a directional shielding approach to prevent neutrons from certain angles from being counted while counting neutrons entering the detector from other angles and explores its potential to gain a sharper horizontal view on the surrounding soil moisture distribution.
Using the Monte Carlo code URANOS (Ultra Rapid Neutron-Only Simulation), we modelled the effect of additional polyethylene shields on the horizontal field of view and assessed its impact on the epithermal count rate, propagated uncertainties and aggregation time.
The results demonstrate that directional CRNS measurements are strongly dominated by isotropic neutron transport, which dilutes the signal of the targeted direction especially from the far field. For typical count rates of customary CRNS stations, directional shielding of half-spaces could not lead to acceptable precision at a daily time resolution. However, the mere statistical distinction of two rates should be feasible.
Characterization and calibration of piezoelectric polymers in situ measurements of body vibrations
(2011)
Piezoelectric polymers are known for their flexibility in applications, mainly due to their bending ability, robustness, and variable sensor geometry. It is an optimal material for minimal-invasive investigations in vibrational systems, e.g., for wood, where acoustical impedance matches particularly well. Many applications may be imagined, e. g., monitoring of buildings, vehicles, machinery, alarm systems, such that our investigations may have a large impact on technology. Longitudinal piezoelectricity converts mechanical vibrations normal to the polymer-film plane into an electrical signal, and the respective piezoelectric coefficient needs to be carefully determined in dependence on the relevant material parameters. In order to evaluate efficiency and durability for piezopolymers, we use polyvinylidene fluoride and measure the piezoelectric coefficient with respect to static pressure, amplitude of the dynamically applied force, and long-term stability. A known problem is the slow relaxation of the material towards equilibrium, if the external pressure changes; here, we demonstrate how to counter this problem with careful calibration. Since our focus is on acoustical measurements, we determine accurately the frequency response curve - for acoustics probably the most important characteristic. Eventually, we show that our piezopolymer transducers can be used as a calibrated acoustical sensors for body vibration measurements on a wooden musical instrument, where it is important to perform minimal-invasive measurements. A comparison with the simultaneously recorded airborne sound yields important insight of the mechanism of sound radiation in comparison with the sound propagating in the material. This is especially important for transient signals, where not only the long-living eigenmodes contribute to the sound radiation. Our analyses support that piezopolymer sensors can be employed as a general tool for the determination of the internal dynamics of vibrating systems.
Although hydrologic models provide hypothesis testing of complex dynamics occurring at catchments, fresh-water quality modeling is still incipient at many subtropical headwaters. In Brazil, a few modeling studies assess freshwater nutrients, limiting policies on hydrologic ecosystem services. This paper aims to compare freshwater quality scenarios under different land-use and land-cover (LULC) change, one of them related to ecosystem-based adaptation (EbA), in Brazilian headwaters. Using the spatially semi-distributed Soil and Water Assessment Tool (SWAT) model, nitrate, total phosphorous (TP) and sediment were modeled in catchments ranging from 7.2 to 1037 km(2). These head-waters were eligible areas of the Brazilian payment for ecosystem services (PES) projects in the Cantareira water supply system, which had supplied water to 9 million people in the Sao Paulo metropolitan region (SPMR). We considered SWAT modeling of three LULC scenarios: (i) recent past scenario (S1), with historical LULC in 1990; (ii) current land-use scenario (S2), with LULC for the period 2010-2015 with field validation; and (iii) future land-use scenario with PES (S2 + EbA). This latter scenario proposed forest cover restoration through EbA following the river basin plan by 2035. These three LULC scenarios were tested with a selected record of rainfall and evapotranspiration observed in 2006-2014, with the occurrence of extreme droughts. To assess hydrologic services, we proposed the hydrologic service index (HSI), as a new composite metric comparing water pollution levels (WPL) for reference catchments, related to the grey water footprint (greyWF) and water yield. On the one hand, water quality simulations allowed for the regionalization of greyWF at spatial scales under LULC scenarios. According to the critical threshold, HSI identified areas as less or more sustainable catchments. On the other hand, conservation practices simulated through the S2 + EbA scenario envisaged not only additional and viable best management practices (BMP), but also preventive decision-making at the headwaters of water supply systems.