Refine
Year of publication
Document Type
- Article (39)
- Postprint (6)
- Doctoral Thesis (1)
Keywords
- LIBS (12)
- Ion mobility spectrometry (9)
- ion mobility spectrometry (5)
- IR-MALDI (4)
- PCA (4)
- Electrospray ionization (3)
- Fluorescence (3)
- HPLC (3)
- Laser (3)
- REMPI (3)
- minerals (3)
- precision agriculture (3)
- soil (3)
- APCI (2)
- Bacteria (2)
- Genetics (2)
- Imaging (2)
- Irradiation (2)
- Mass spectrometry (2)
- PLS regression (2)
- PLSR (2)
- Photodynamics (2)
- UVR (2)
- copper-bearing minerals (2)
- elemental composition (2)
- gas chromatography (2)
- gaussian processes (2)
- iPLS regression (2)
- laser-induced breakdown spectroscopy (2)
- lasso (2)
- mass spectrometry (2)
- nutrients (2)
- proximal soil sensing (2)
- rare earth elements (2)
- reaction monitoring (2)
- soil nutrients (2)
- Acoustic levitation (1)
- Ambient pressure laser ionization (1)
- Amino acids (1)
- Collision cross-section (1)
- ESI (1)
- Electrospray Ionization (1)
- Fabry-Perot etalon (1)
- Gas chromatography (1)
- Gaseous Ions (1)
- HALS (1)
- High-resolution spectrometer (1)
- Hydrogen sulfide (1)
- IMS (1)
- Ion optics (1)
- Ionization (1)
- Ionmobility spectrometry (1)
- LII (1)
- Laser ablation (1)
- Laser ionization (1)
- Laser-induced breakdown spectroscopy (1)
- Lucigenin (1)
- Molecular dynamics (1)
- NTF (1)
- Neuroleptics (1)
- Olefin isomerization (1)
- PAH (1)
- Peptides (1)
- Pesticides (1)
- Plume (1)
- Proton transfer reaction (1)
- Pulse duration (1)
- Raman spectroscopy (1)
- Rhodamine 6G (1)
- Shadowgraphy (1)
- Subambient pressure (1)
- Two-dimensional separations (1)
- X-ray (1)
- aerosol. photoacoustics (1)
- alkyl nitrates (1)
- classification (1)
- copper minerals (1)
- dub-ambient (1)
- electrospray ionization (1)
- explosives (1)
- feature selection (1)
- fungus (1)
- high field mobility (1)
- mass (1)
- microchip (1)
- mold (1)
- mold fungi (1)
- multivariate methods (1)
- neuroleptics (1)
- peptides (1)
- pesticides (1)
- photocatalysis (1)
- photochemistry (1)
- photoionization (1)
- pressure (1)
- reaction mechanisms (1)
- soft X-radiation (1)
- soft X-ray (1)
- spectrometry (1)
- spray imaging (1)
- stroboscopic imaging (1)
- surfactants (1)
- volatile organic compounds (1)
Institute
The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text
The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text
Mold fungi on malting barley grains cause major economic loss in malting and brewery facilities. Possible proxies for their detection are volatile and semivolatile metabolites. Among those substances, characteristic marker compounds have to be identified for a confident detection of mold fungi in varying surroundings. The analytical determination is usually performed through passive sampling with solid phase microextraction, gas chromatographic separation, and detection by electron ionization mass spectrometry (EI-MS), which often does not allow a confident determination due to the absence of molecular ions. An alternative is GC-APCI-MS, generally, allowing the determination of protonated molecular ions. Commercial atmospheric pressure chemical ionization (APCI) sources are based on corona discharges, which are often unspecific due to the occurrence of several side reactions and produce complex product ion spectra. To overcome this issue, an APCI source based on soft X-radiation is used here. This source facilitates a more specific ionization by proton transfer reactions only. In the first part, the APCI source is characterized with representative volatile fungus metabolites. Depending on the proton affinity of the metabolites, the limits of detection are up to 2 orders of magnitude below those of EI-MS. In the second part, the volatile metabolites of the mold fungus species Aspergillus, Alternaria, Fusarium, and Penicillium are investigated. In total, 86 compounds were found with GC-EI/APCI-MS. The metabolites identified belong to the substance classes of alcohols, aldehydes, ketones, carboxylic acids, esters, substituted aromatic compounds, terpenes, and sesquiterpenes. In addition to substances unspecific for the individual fungus species, characteristic patterns of metabolites, allowing their confident discrimination, were found for each of the 4 fungus species. Sixty-seven of the 86 metabolites are detected by X-ray-based APCI-MS alone. The discrimination of the fungus species based on these metabolites alone was possible. Therefore, APCI-MS in combination with collision induced dissociation alone could be used as a supervision method for the detection of mold fungi.
The combination of high-performance liquid chromatography and electrospray ionization ion mobility spectrometry facilitates the two-dimensional separation of complex mixtures in the retention and drift time plane. The ion mobility spectrometer presented here was optimized for flow rates customarily used in high-performance liquid chromatography between 100 and 1500 mu L/min. The characterization of the system with respect to such parameters as the peak capacity of each time dimension and of the 2D spectrum was carried out based on a separation of a pesticide mixture containing 24 substances. While the total ion current chromatogram is coarsely resolved, exhibiting coelutions for a number of compounds, all substances can be separately detected in the 2D plane due to the orthogonality of the separations in retention and drift dimensions. Another major advantage of the ion mobility detector is the identification of substances based on their characteristic mobilities. Electrospray ionization allows the detection of substances lacking a chromophore. As an example, the separation of a mixture of 18 amino acids is presented. A software built upon the free mass spectrometry package OpenMS was developed for processing the extensive 2D data. The different processing steps are implemented as separate modules which can be arranged in a graphic workflow facilitating automated processing of data.
In this paper the concept of a compact high-resolution spectrometer based on the combination of dispersive and interferometric elements is presented. Dispersive elements are used to spectrally resolve the light in one direction with coarse resolution (Delta lambda < 0.5 nm), while perpendicular to that direction an etalon provides high spectral resolution (Delta lambda < 50 pm). This concept for two-dimensional spectroscopy has been implemented for the wavelength range lambda = 350-650 nm. Appropriate algorithms for reconstructing spectra from the two-dimensional raw data and for wavelength calibration were established in an analysis software. Potential applications for this new spectrometer are Raman and laser-induced breakdown spectroscopy (LIBS). Resolutions down to 28 pm (routinely 54 pm) could be realized for these applications.
The visible-light photocatalyticE/Zisomerization of olefins can be mediated by a wide spectrum of triplet sensitizers (photocatalysts). However, the search for the most efficient photocatalysts through screenings in photo batch reactors is material and time consuming. Capillary and microchip flow reactors can accelerate this screening process. Combined with a fast analytical technique for isomer differentiation, these reactors can enable high-throughput analyses. Ion mobility (IM) spectrometry is a cost-effective technique that allows simple isomer separation and detection on the millisecond timescale. This work introduces a hyphenation method consisting of a microchip reactor and an infrared matrix-assisted laser desorption ionization (IR-MALDI) ion mobility spectrometer that has the potential for high-throughput analysis. The photocatalyzedE/Zisomerization of ethyl-3-(pyridine-3-yl)but-2-enoate (E-1) as a model substrate was chosen to demonstrate the capability of this device. Classic organic triplet sensitizers as well as Ru-, Ir-, and Cu-based complexes were tested as catalysts. The ionization efficiency of theZ-isomer is much higher at atmospheric pressure which is due to a higher proton affinity. In order to suppress proton transfer reactions by limiting the number of collisions, an IM spectrometer working at reduced pressure (max. 100 mbar) was employed. This design reduced charge transfer reactions and allowed the quantitative determination of the reaction yield in real time. Among 14 catalysts tested, four catalysts could be determined as efficient sensitizers for theE/Zisomerization of ethyl cinnamate derivativeE-1. Conversion rates of up to 80% were achieved in irradiation time sequences of 10 up to 180 s. With respect to current studies found in the literature, this reduces the acquisition times from several hours to only a few minutes per scan.
The quantification and identification of aerosols in industry plays a key role in process monitoring and control and lays the foundation for process automation aspired by the industry 4.0 initiative.
However, measuring particulate matter's mass and number concentrations in harsh environments poses great analytical constraints.
The presented approach comprises a comprehensive set of light-and imaging-based techniques, all contactless, in-line, and real-time. It includes, but is not limited to, stroboscopic imaging, laser-induced breakdown spectroscopy (LIBS) and laser-induced incandescence (LII). Stroboscopic imaging confirmed the particles sphericity and was used to measure the particle number density. A phase-selective LIBS setup with low fluence and 500 Hz repetition rate was used to classify each particle with a single-pulse and in real time. Simultaneously, the created plasma was captured by CCD imaging to determine the detection volume and hit rate of the LIBS setup.
Both data sets combined were converted to a particle number density, which was consistent with the particle number density of the stroboscopic measurements. Furthermore, using a photodiode and microphone in parallel to the LIBS setup allowed for the photoacoustic normalization of the spectral line intensity at the laser repetition rate of 500 Hz.
This was done as a partial photoacoustic normalization method with the cut-off based on the coefficient of variation (CV), reducing it by 25%. Aside from that photodiode and microphone were proven to be valuable event counting with the advantage of the less spatially constricted. A second laser setup was used for laser -induced incandescence (LII) making it possible to classify the particles based on their incandescence tendency. Given its larger probing volume, LII could be employed at very low particle number densities.
With respect to the current literature, this is the first approach of using LII as an in-line, real-time analytical technique for the compositional classification of metal-bearing aerosols.
Laser-based ion mobility (IM) spectrometry was used for the detection of neuroleptics and PAH. A gas chromatograph was connected to the IM spectrometer in order to investigate compounds with low vapour pressure. The substances were ionized by resonant two-photon ionization at the wavelengths lambda = 213 and 266 nm and pulse energies between 50 and 300 mu J. Ion mobilities, linear ranges, limits of detection and response factors are reported. Limits of detection for the substances are in the range of 1-50 fmol. Additionally, the mechanism of laser ionization at atmospheric pressure was investigated. First, the primary product ions were determined by a laser-based time-of-flight mass spectrometer with effusive sample introduction. Then, a combination of a laser-based IM spectrometer and an ion trap mass spectrometer was developed and characterized to elucidate secondary ion-molecule reactions that can occur at atmospheric pressure. Some substances, namely naphthalene, anthracene, promazine and thioridazine, could be detected as primary ions (radical cations), while other substances, in particular acridine, phenothiazine and chlorprothixene, are detected as secondary ions (protonated molecules). The results are interpreted on the basis of quantum chemical calculations, and an ionization mechanism is proposed.