Detection of subicomolar concentrations of human matrix metalloproteinase-2 by an optical biosensor
- We describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3% for five determinations of 1 pM MMP- 2. NoWe describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3% for five determinations of 1 pM MMP- 2. No significant binding was observed with the structurally related MMP-9. The assay is far more sensitive and faster than commonly used methods for MMP-2 detection. As TIMP-bound MMP-2 is not detected by this method, the assay can be applied for measuring free MMP-2, reflecting the imbalance of free and inhibitor-bound enzyme in various pathological situations. (C) 2004 Elsevier Inc. All rights reserved…
Author details: | U. Pieper-Fürst, U. Kleuser, Walter F. M. Stöcklein, Axel WarsinkeGND, Frieder W. SchellerORCiDGND |
---|---|
Publication type: | Article |
Language: | English |
Year of first publication: | 2004 |
Publication year: | 2004 |
Release date: | 2017/03/24 |
Source: | Analytical Biochemistry. - 332 (2004), S. 160 - 167 |
Organizational units: | Mathematisch-Naturwissenschaftliche Fakultät / Institut für Biochemie und Biologie |
Peer review: | Referiert |