Assessing the validity of inertial measurement units for shoulder kinematics using a commercial sensor-software system
- Background and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 +/- 4 years, height 177 +/- 11 cm, weight 73 +/- 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficientsBackground and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 +/- 4 years, height 177 +/- 11 cm, weight 73 +/- 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficients (ICC), root mean square error (RMSE) and Bland and Altmann analysis (bias; upper and lower limits of agreement). Results ROM and TROM analysis revealed inconsistent validity during simple (ICC: 0.040-0.733, RMSE: 9.7 degrees-20.3 degrees, bias: 1.2 degrees-50.7 degrees) and insufficient agreement during complex shoulder movements (ICC: 0.104-0.453, RMSE: 10.1 degrees-23.3 degrees, bias: 1.0 degrees-55.9 degrees). Peak angular velocity (ICC: 0.202-0.865, RMSE: 14.6 degrees/s-26.7 degrees/s, bias: 10.2 degrees/s-29.9 degrees/s) and mean angular velocity (ICC: 0.019-0.786, RMSE:6.1 degrees/s-34.2 degrees/s, bias: 1.6 degrees/s-27.8 degrees/s) were inconsistent. Conclusions The "off-the-shelf" sensor-software system showed overall insufficient agreement with the gold standard. Further development of commercial IMU-software-solutions may increase measurement accuracy and permit their integration into everyday clinical practice.…
Author details: | Jakob HenschkeORCiD, Hannes Kaplick, Monique WochatzORCiDGND, Tilman EngelORCiDGND |
---|---|
DOI: | https://doi.org/10.1002/hsr2.772 |
ISSN: | 2398-8835 |
Title of parent work (English): | Health science reports |
Subtitle (English): | a validation study |
Publisher: | Wiley |
Place of publishing: | Hoboken |
Publication type: | Article |
Language: | English |
Date of first publication: | 2022/08/10 |
Publication year: | 2022 |
Release date: | 2022/10/17 |
Tag: | diagnostic techniques and procedures; kinematics; shoulder joint; validation study; wearable devices |
Volume: | 5 |
Issue: | 5 |
Article number: | e772 |
Number of pages: | 11 |
First page: | 1 |
Last Page: | 11 |
Funding institution: | Projekt DEAL |
Organizational units: | Organe und Gremien / Gesundheitsmanagement |
DDC classification: | 6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit |
Peer review: | Referiert |
Publishing method: | Open Access / Gold Open-Access |
DOAJ gelistet | |
License (German): | CC-BY - Namensnennung 4.0 International |
External remark: | Zweitveröffentlichung in der Schriftenreihe Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe ; 809 |