Piezoelectric affinity sensors for cocaine and cholinesterase inhibitors

  • We report here the development of piezoelectric affinity sensors for cocaine and cholinesterase inhibitors based on the formation of affinity complexes between an immobilized cocaine derivative and an anti-cocaine antibody or cholinesterase. For both binding reactions benzoylecgonine-1,8-diamino-3,4-dioxaoctane (BZE-DADOO) was immobilized on the surface of the sensor. For immobilization. pre-conjugated BZE-DADOO with 11-mercaptomonoundecanoic acid (MUA) via 2- (5-norbornen-2,3-dicarboximide)-1,1,3,3-tetramethyluronium-tetrafluoro borate (TNTU) allowed the formation of a chemisorbed monolayer on the piezosensor surface. The detection of cocaine was based oil a competitive assay. The change of frequency measured after 300 s of the binding reaction was used as the signal. The maximum binding of the antibody resulted in a frequency decrease of 35 Hz (with an imprecision 3%, n = 3) while the presence of 100 pmol I-1 cocaine decreased the binding by 11%. The limit of detection was consequently below 100 pmol I-1 for cocaine. The total timeWe report here the development of piezoelectric affinity sensors for cocaine and cholinesterase inhibitors based on the formation of affinity complexes between an immobilized cocaine derivative and an anti-cocaine antibody or cholinesterase. For both binding reactions benzoylecgonine-1,8-diamino-3,4-dioxaoctane (BZE-DADOO) was immobilized on the surface of the sensor. For immobilization. pre-conjugated BZE-DADOO with 11-mercaptomonoundecanoic acid (MUA) via 2- (5-norbornen-2,3-dicarboximide)-1,1,3,3-tetramethyluronium-tetrafluoro borate (TNTU) allowed the formation of a chemisorbed monolayer on the piezosensor surface. The detection of cocaine was based oil a competitive assay. The change of frequency measured after 300 s of the binding reaction was used as the signal. The maximum binding of the antibody resulted in a frequency decrease of 35 Hz (with an imprecision 3%, n = 3) while the presence of 100 pmol I-1 cocaine decreased the binding by 11%. The limit of detection was consequently below 100 pmol I-1 for cocaine. The total time of one analysis was 15 min. This BZE-DADOO-modified sensor was adapted for the detection of organophosphates. BZE-DADOO - a competitive inhibitor - served as binding element for cholinesterase in a competitive assay. (C) 2004 Elsevier B.V. All rights reservedzeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Jan Halamek, Alexander Makower, Kristina Knösche, Petr Skladal, Frieder W. SchellerORCiDGND
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2005
Erscheinungsjahr:2005
Datum der Freischaltung:24.03.2017
Quelle:Talanta. - 65 (2005), S. 337 - 342
Organisationseinheiten:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Biochemie und Biologie
Peer Review:Referiert
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.