Piezoelectric affinity sensors for cocaine and cholinesterase inhibitors

  • We report here the development of piezoelectric affinity sensors for cocaine and cholinesterase inhibitors based on the formation of affinity complexes between an immobilized cocaine derivative and an anti-cocaine antibody or cholinesterase. For both binding reactions benzoylecgonine-1,8-diamino-3,4-dioxaoctane (BZE-DADOO) was immobilized on the surface of the sensor. For immobilization. pre-conjugated BZE-DADOO with 11-mercaptomonoundecanoic acid (MUA) via 2- (5-norbornen-2,3-dicarboximide)-1,1,3,3-tetramethyluronium-tetrafluoro borate (TNTU) allowed the formation of a chemisorbed monolayer on the piezosensor surface. The detection of cocaine was based oil a competitive assay. The change of frequency measured after 300 s of the binding reaction was used as the signal. The maximum binding of the antibody resulted in a frequency decrease of 35 Hz (with an imprecision 3%, n = 3) while the presence of 100 pmol I-1 cocaine decreased the binding by 11%. The limit of detection was consequently below 100 pmol I-1 for cocaine. The total timeWe report here the development of piezoelectric affinity sensors for cocaine and cholinesterase inhibitors based on the formation of affinity complexes between an immobilized cocaine derivative and an anti-cocaine antibody or cholinesterase. For both binding reactions benzoylecgonine-1,8-diamino-3,4-dioxaoctane (BZE-DADOO) was immobilized on the surface of the sensor. For immobilization. pre-conjugated BZE-DADOO with 11-mercaptomonoundecanoic acid (MUA) via 2- (5-norbornen-2,3-dicarboximide)-1,1,3,3-tetramethyluronium-tetrafluoro borate (TNTU) allowed the formation of a chemisorbed monolayer on the piezosensor surface. The detection of cocaine was based oil a competitive assay. The change of frequency measured after 300 s of the binding reaction was used as the signal. The maximum binding of the antibody resulted in a frequency decrease of 35 Hz (with an imprecision 3%, n = 3) while the presence of 100 pmol I-1 cocaine decreased the binding by 11%. The limit of detection was consequently below 100 pmol I-1 for cocaine. The total time of one analysis was 15 min. This BZE-DADOO-modified sensor was adapted for the detection of organophosphates. BZE-DADOO - a competitive inhibitor - served as binding element for cholinesterase in a competitive assay. (C) 2004 Elsevier B.V. All rights reservedshow moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:Jan Halamek, Alexander Makower, Kristina Knösche, Petr Skladal, Frieder W. SchellerORCiDGND
Publication type:Article
Language:English
Year of first publication:2005
Publication year:2005
Release date:2017/03/24
Source:Talanta. - 65 (2005), S. 337 - 342
Organizational units:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Biochemie und Biologie
Peer review:Referiert
Accept ✔
This website uses technically necessary session cookies. By continuing to use the website, you agree to this. You can find our privacy policy here.