Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 10 von 79
Zurück zur Trefferliste

Orientations of broadband stations of the KOERI seismic network (Turkey) from two independent methods

  • The correct orientation of seismic sensors is critical for studies such as full moment tensor inversion, receiver function analysis, and shear-wave splitting. Therefore, the orientation of horizontal components needs to be checked and verified systematically. This study relies on two different waveform-based approaches, to assess the sensor orientations of the broadband network of the Kandilli Observatory and Earthquake Research Institute (KOERI). The network is an important backbone for seismological research in the Eastern Mediterranean Region and provides a comprehensive seismic data set for the North Anatolian fault. In recent years, this region became a worldwide field laboratory for continental transform faults. A systematic survey of the sensor orientations of the entire network, as presented here, facilitates related seismic studies. We apply two independent orientation tests, based on the polarization of P waves and Rayleigh waves to 123 broadband seismic stations, covering a period of 15 yr (2004-2018). For 114 stations, weThe correct orientation of seismic sensors is critical for studies such as full moment tensor inversion, receiver function analysis, and shear-wave splitting. Therefore, the orientation of horizontal components needs to be checked and verified systematically. This study relies on two different waveform-based approaches, to assess the sensor orientations of the broadband network of the Kandilli Observatory and Earthquake Research Institute (KOERI). The network is an important backbone for seismological research in the Eastern Mediterranean Region and provides a comprehensive seismic data set for the North Anatolian fault. In recent years, this region became a worldwide field laboratory for continental transform faults. A systematic survey of the sensor orientations of the entire network, as presented here, facilitates related seismic studies. We apply two independent orientation tests, based on the polarization of P waves and Rayleigh waves to 123 broadband seismic stations, covering a period of 15 yr (2004-2018). For 114 stations, we obtain stable results with both methods. Approximately, 80% of the results agree with each other within 10 degrees. Both methods indicate that about 40% of the stations are misoriented by more than 10 degrees. Among these, 20 stations are misoriented by more than 20 degrees. We observe temporal changes of sensor orientation that coincide with maintenance work or instrument replacement. We provide time-dependent sensor misorientation correction values for the KOERI network in the supplemental material.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Pınar BüyükakpınarORCiD, Mustafa AktarORCiD, Gesa Maria PetersenORCiDGND, Ayşegül Köseoğlu
DOI:https://doi.org/10.1785/0220200362
ISSN:0895-0695
ISSN:1938-2057
Titel des übergeordneten Werks (Englisch):Seismological research letters / Seismological Society of America
Untertitel (Englisch):P- and Rayleigh-wave polarization
Verlag:Seismological Society of America
Verlagsort:Boulder, Colo.
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Datum der Erstveröffentlichung:27.01.2021
Erscheinungsjahr:2021
Datum der Freischaltung:15.04.2024
Band:92
Ausgabe:3
Seitenanzahl:10
Erste Seite:1512
Letzte Seite:1521
Fördernde Institution:Bogazici University Research Fund (BAP)Bogazici University [15683 (19T04P1)]; Deutsche Forschungsgemeinschaft (DFG)German Research Foundation (DFG) [362440331, 313806092]
Organisationseinheiten:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Geowissenschaften
DDC-Klassifikation:5 Naturwissenschaften und Mathematik / 55 Geowissenschaften, Geologie / 550 Geowissenschaften
Peer Review:Referiert
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.