• search hit 1 of 3
Back to Result List

Gold nanoparticle-enhanced surface plasmon resonance measurement with a highly sensitive quantification for human tissue inhibitor of metalloproteinases-2

  • Two different methods for the quantification of human tissue inhibitor of metalloproteinases-2 (TIMP-2) were developed using surface plasmon resonance (SPR) and gold nanoparticles for signal enhancement. The first method, a competitive assay, used TIMP-2 immobilized to the sensor surface and the inactive form of matrix metalloproteinase-2 (proMMP-2) (EC 3.4.24.24) adsorbed to gold nanoparticles. The sensor signals resulting from the interaction of MMP-2- gold nanoparticles with immobilized TIMP-2 were inversely proportional to the amounts of TIMP-2 of the sample. The measuring range for TIMP-2 was about 15-180pM. The second method, a one-step sandwich assay, used proMMP-2 immobilized to the sensor surface and an anti-TIMP-2 monoclonal antibody coupled to gold nanoparticles. The lower detection limit of this assay format was 0.5 pM of TIMP-2. The binding signals were highly reproducible up to 100 pM of the inhibitor. The improvements obtained in TIMP-2 quantification over already existing tests could contribute to a betterTwo different methods for the quantification of human tissue inhibitor of metalloproteinases-2 (TIMP-2) were developed using surface plasmon resonance (SPR) and gold nanoparticles for signal enhancement. The first method, a competitive assay, used TIMP-2 immobilized to the sensor surface and the inactive form of matrix metalloproteinase-2 (proMMP-2) (EC 3.4.24.24) adsorbed to gold nanoparticles. The sensor signals resulting from the interaction of MMP-2- gold nanoparticles with immobilized TIMP-2 were inversely proportional to the amounts of TIMP-2 of the sample. The measuring range for TIMP-2 was about 15-180pM. The second method, a one-step sandwich assay, used proMMP-2 immobilized to the sensor surface and an anti-TIMP-2 monoclonal antibody coupled to gold nanoparticles. The lower detection limit of this assay format was 0.5 pM of TIMP-2. The binding signals were highly reproducible up to 100 pM of the inhibitor. The improvements obtained in TIMP-2 quantification over already existing tests could contribute to a better understanding and diagnosis of diseases like cancer. (c) 2005 Elsevier B.V. All rights reservedshow moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:U. Pieper-Fürst
Further contributing person(s):Walter F. M. Stöcklein, Axel Warsinke
Publication type:Article
Language:English
Year of first publication:2005
Publication year:2005
Release date:2017/03/24
Source:Analytica chimica acta. - 550 (2005), S. 69 - 76
Organizational units:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Biochemie und Biologie
Peer review:Referiert
Accept ✔
This website uses technically necessary session cookies. By continuing to use the website, you agree to this. You can find our privacy policy here.