Accuracy of Continuous Glucose Monitoring (CGM) during continuous and high-intensity interval exercise in patients with Type 1 Diabetes Mellitus

  • Continuous exercise (CON) and high-intensity interval exercise (HIIE) can be safely performed with type 1 diabetes mellitus (T1DM). Additionally, continuous glucose monitoring (CGM) systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L) and above (M) the first lactate turn point (LTP1), and 5% below the second lactate turn point (LTP2) (H) on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG). Differences were found in comparison of CGM vs. BG in three out of the six tests (p < 0.05). In CON, bias and levels of agreement for L, M, and H were found at: 0.85 (−3.44, 5.15) mmol·L−1, −0.45 (−3.95, 3.05) mmol·L−1, −0.31 (−8.83, 8.20) mmol·L−1 and at 1.17 (−2.06, 4.40) mmol·L−1, 0.11 (−5.79, 6.01) mmol·L−1, 1.48 (−2.60, 5.57) mmol·L−1 in HIIE for the same intensities. Clinically-acceptable results (except for CON H) were found. CGM estimated BG to beContinuous exercise (CON) and high-intensity interval exercise (HIIE) can be safely performed with type 1 diabetes mellitus (T1DM). Additionally, continuous glucose monitoring (CGM) systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L) and above (M) the first lactate turn point (LTP1), and 5% below the second lactate turn point (LTP2) (H) on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG). Differences were found in comparison of CGM vs. BG in three out of the six tests (p < 0.05). In CON, bias and levels of agreement for L, M, and H were found at: 0.85 (−3.44, 5.15) mmol·L−1, −0.45 (−3.95, 3.05) mmol·L−1, −0.31 (−8.83, 8.20) mmol·L−1 and at 1.17 (−2.06, 4.40) mmol·L−1, 0.11 (−5.79, 6.01) mmol·L−1, 1.48 (−2.60, 5.57) mmol·L−1 in HIIE for the same intensities. Clinically-acceptable results (except for CON H) were found. CGM estimated BG to be clinically acceptable, except for CON H. Additionally, using CGM may increase avoidance of exercise-induced hypoglycemia, but usual BG control should be performed during intense exercise.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Othmar Moser, Julia K. Mader, Gerhard TschakertORCiD, Alexander Mueller, Werner Groeschl, Thomas R. Pieber, Gerd Koehler, Janin Messerschmidt, Peter Hofmann
URN:urn:nbn:de:kobv:517-opus4-400470
Schriftenreihe (Bandnummer):Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe (338)
Publikationstyp:Postprint
Sprache:Englisch
Datum der Erstveröffentlichung:21.09.2017
Erscheinungsjahr:2017
Veröffentlichende Institution:Universität Potsdam
Datum der Freischaltung:21.09.2017
Freies Schlagwort / Tag:blood glucose; continuous glucose monitoring; diabetes; exercise
Seitenanzahl:15
Quelle:Nutrients 8 (2016) Nr. 8. - DOI: 10.3390/nu8080489
Organisationseinheiten:Humanwissenschaftliche Fakultät
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Peer Review:Referiert
Publikationsweg:Open Access
Fördermittelquelle:Multidisciplinary Digital Publishing Institute (MDPI)
Lizenz (Deutsch):License LogoCC-BY - Namensnennung 4.0 International
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.