Refine
Year of publication
Document Type
- Article (118)
- Postprint (2)
- Monograph/Edited Volume (1)
- Doctoral Thesis (1)
Is part of the Bibliography
- yes (122)
Keywords
- Direct electron transfer (4)
- Aldehyde oxidoreductase (3)
- Bioelectrocatalysis (3)
- Biosensors (3)
- bioelectrocatalysis (3)
- electron transfer (3)
- hydrogen peroxide (3)
- Biofuel cell (2)
- Biosensor (2)
- Cytochrome P450 (2)
Institute
- Institut für Biochemie und Biologie (122) (remove)
The present study reports a facile approach for sulfite biosensing, based on enhanced direct electron transfer of a human sulfite oxidase (hSO) immobilized on a gold nanoparticles modified electrode. The spherical core shell AuNPs were prepared via a new method by reduction of HAuCl4 with branched poly(ethyleneimine) in an ionic liquids resulting particles with a diameter less than 10 nm. These nanoparticles were covalently attached to a mercaptoundecanoic acid modified Au-electrode where then hSO was adsorbed and an enhanced interfacial electron transfer and electrocatalysis was achieved. UV/Vis and resonance Raman spectroscopy, in combination with direct protein voltammetry, are employed for the characterization of the system and reveal no perturbation of the structural integrity of the redox protein. The proposed biosensor exhibited a quick steady-state current response, within 2 s, a linear detection range between 0.5 and 5.4 mu M with a high sensitivity (1.85 nA mu M-1). The investigated system provides remarkable advantages in the possibility to work at low applied potential and at very high ionic strength. Therefore these properties could make the proposed system useful in the development of bioelectronic devices and its application in real samples.
Electrochemical polymerization of functionalized thiohene derivatives for immobilization of proteins
(1997)
A biosensor, based on a redoxactive osmium polymer and sulfite oxidase on screen-printed electrodes, is presented here as a promising method for the detection of sulfite. A catalytic oxidative current was generated when a sample containing sulfite was pumped over the carbon screen-printed electrode modified with osmium redox polymer wired sulfite oxidase. A stationary value was reached after approximately 50 s and a complete measurement lasted no more than 3 min. The electrode polarized at -0.1 V (vs. Ag vertical bar AgCl 1M KCl) permits minimizing the influence of interfering substances, since these compounds can be unspecific oxidized at higher potentials. Because of the good stability of the protein film on the electrode surface, a well functioning biosensor-flow system was possible to construct. The working stability and reproducibility were further enhanced by the addition of bovine serum albumin generating a more long-term stable and biocompatible protein environment. The optimized biosensor showed a stable signal for more than a week of operation and a coefficient of variation of 4.8% for 12 successive measurements. The lower limit of detection of the sensor was 0.5 mu M sulfite and the response was linear until 100 mu M. The high sensitivity permitted a 1:500 dilution of wine samples. The immobilization procedure and the operational conditions granted minimized interferences. Additionally, repeating the immobilization procedure to form several layers of wired SO further increased the sensitivity of such a sensor. Finally. the applicability of the developed sulfite biosensor was tested on real samples, such as white and red wines.
Direct electrochemistry and spectroelectrochemistry of osmium substituted horseradish peroxidase
(2009)
In this contribution the substitution of the central protoporphyrin IX iron complex of horseradish peroxidase by the respective osmium porphyrin complex is described. The direct electrochemical reduction of the Os containing horseradish peroxidase (OsHRP) was achieved at ITO and modified glassy carbon electrodes and in combination with spectroscopy revealed the three redox couples (OsHRP)-H-III/(OsHRP)-H-IV, (OsHRP)-H-IV/(OsHRP)-H-V and (OsHRP)-H-V/ (OsHRP)-H-VI. The midpoint potentials differ dependent on the electrode material used with E-1/2 (Os-III/IV) of -0.4 V (ITO) and -0.25 V (GC), E-1/2 (Os-IV/V) of -0.16 V (ITO) and +0.10 V (GC), and E-1/2 (Os-V/VI)of +018 V (ITO), respectively Moreover, with immobilised OsHRP the direct electrocatalytic reduction of hydrogen peroxide and tert-butyl hydroperoxide was observed. In comparison to electrodes modified with native HRP the sensitivity of the OsHRP-electrode for tert-butyl hydroperoxide is higher.