Refine
Language
- English (23)
Is part of the Bibliography
- yes (23)
Keywords
- Perturbation (5)
- MiSpEx (4)
- Exercise (3)
- Sensorimotor training (3)
- EMG (2)
- MiSpEx* (2)
- Stumbling (2)
- Telerehabilitation (2)
- aftercare (2)
- core (2)
Repetitive overhead movements have been identified as a main risk factor to develop shoulder complaints with scapular muscle activity being altered. Reliable assessment of muscle activity is essential to differentiate between symptomatic and asymptomatic individuals. Therefore, the present study aimed to investigate the intra-and inter-session reliability of scapular muscle activity during maximal isokinetic shoulder flexion and extension. Eleven asymptomatic adults performed maximum effort isokinetic shoulder flexion and extension (concentric and eccentric at 60 degrees/s) in a test-retest design. Muscle activity of the upper and lower trapezius and serratus anterior was assessed by sEMG. Root Mean Square was calculated for whole ROM and single movement phases of absolute and normalized muscle activity. Absolute (Bland-Altman analysis (Bias, LoA), Minimal detectable change (MDC)) and relative reliability parameters (Intraclass correlation coefficient (ICC), coefficient of variation (CV)/test-retest variability (TRV)) were utilized for the evaluation of reproducibility. Intra-session reliability revealed ICCs between 0.56 and 0.98, averaged CVs of 18% and average MDCs of 81 mV. Inter-session reliability resulted in ICCs between 0.13 and 0.93, averaged TRVs of 21%, average MDCs of 15% and systematic and random error between -8 +/- 60% and 12 +/- 36%. Scapular muscle activity assessed in overhead movements can be measured reliably under maximum load conditions, though variability is dependent on the movement phase. Measurement variability does not exceed magnitudes of altered scapular muscle activities as reported in previous studies. Therefore, maximum load application is a promising approach for the evaluation of changes in scapular control related to pathologies. (C) 2017 Elsevier Ltd. All rights reserved.
BACKGROUND: Compensating unstable situations is an important functional capability to maintain joint stability, to compensate perturbations and to prevent (re-)injury. Therefore, reduced maximum strength and altered neuromuscular activity are expected by inducing instability to load test situations. Possible effects are not clear for induced instability during maximum legpress tests in healthy individuals. OBJECTIVE: To compare isokinetic legpress (LP) strength and lower-leg muscle activity using stable (S) and unstable (UN) footplates. METHODS: 16 males (28 +/- 4 yrs, 179 +/- 7 cm, 75 +/- 8 kg) performed five maximum LP in concentric (CON) and eccentric (ECC) mode. The maximum force (Fmax) and muscle activity were measured under conditions of S and UN footplates. The tested muscles comprised of the tibialis anterior (TA), peroneus longus (PL) and soleus (SOL) and their activity were quantified against the MVIC of each muscle respectively. RESULTS: The main finding revealed a significant reduction in Fmax under UN condition: 11.9 +/- 11.3% in CON and 23.5 +/- 47.8% in ECC (P < 0.05). Significant findings were also noted regarding the RMS derived values of the EMG of PL and TA. CONCLUSION: Unstable LP reduced force generation and increased the activity of PL and TA muscles which confirmed greater neuromuscular effort to compensate instability. This may have some implications for resistance testing and training coupled with an unstable base in the prevention and rehabilitation of injury to the neuromusculoskeletal system.
The aim of this study was to investigate the effect of a 6-week sensorimotor or resistance training on maximum trunk strength and response to sudden, high-intensity loading in athletes. Interventions showed no significant difference for maximum strength in concentric and eccentric testing (p>0.05). For perturbation compensation, higher peak torque response following SMT (Extension: +24Nm 95%CI +/- 19Nm; Rotation: + 19Nm 95%CI +/- 13Nm) and RT (Extension: +35Nm 95%CI +/- 16Nm; Rotation: +5Nm 95%CI +/- 4Nm) compared to CG (Extension: -4Nm 95%CI +/- 16Nm; Rotation: -2Nm 95%CI +/- 4Nm) was present (p<0.05).