Refine
Has Fulltext
- no (3)
Document Type
- Article (3) (remove)
Language
- English (3)
Is part of the Bibliography
- yes (3)
Keywords
- Actuators (1)
- manufacturing automation (1)
- optical interconnections (1)
- packaging (1)
- position control (1)
Institute
Reproducibility is a defining feature of science, but the extent to which it characterizes current research is unknown. We conducted replications of 100 experimental and correlational studies published in three psychology journals using high-powered designs and original materials when available. Replication effects were half the magnitude of original effects, representing a substantial decline. Ninety-seven percent of original studies had statistically significant results. Thirty-six percent of replications had statistically significant results; 47% of original effect sizes were in the 95% confidence interval of the replication effect size; 39% of effects were subjectively rated to have replicated the original result; and if no bias in original results is assumed, combining original and replication results left 68% with statistically significant effects. Correlational tests suggest that replication success was better predicted by the strength of original evidence than by characteristics of the original and replication teams.
We present accurate electromechanical measurements on a balanced push-pull dielectric elastomer actuator, demonstrating submicrometer accurate position control. An analytical model based on a simplified pure-shear dielectric elastomer film with prestretch is found to capture the voltage-displacement behavior, with reduced output due to the boundary conditions. Two complementary experiments show that actuation coefficients of 0.5-1 nm/V-2 are obtainable with the demonstrated device, enabling motion control with submicrometer accuracy in a voltage range below 200 V.
Analysis of the operating characteristics of a dielectric elastomer actuator (DEA) submount for the high-precision positioning of optical components in one dimension is presented. Precise alignment of a single-mode fiber is demonstrated and variation of the sensitivity of the submount motion by changing the bias voltage is confirmed. A comparison of the performance of the DEA submount with a piezoelectric alignment stage is made, which demonstrates that DEAs could present a very attractive, low-cost alternative to currently used manual technologies in overcoming the hurdle of expensive packaging of single-mode optical components.