Refine
Document Type
- Article (4)
- Postprint (2)
- Doctoral Thesis (1)
Is part of the Bibliography
- yes (7)
Keywords
- arsenious acid (2)
- fronts (2)
- paper (2)
- poly(dimethylsiloxane) (2)
- scale (2)
- systems (2)
- DNA (1)
- HPµF (1)
- Hydrogel (1)
- Mikrofluidik (1)
- POCT (1)
- Pathogenerkennung (1)
- biomolecule (1)
- chemical clock (1)
- cross layer chip (1)
- fiber-electrophoresis chip (1)
- functionalization (1)
- hydrogel (1)
- imprinted electrodes (1)
- microfluidic paper analytic device (mu PAD) (1)
- nonlinear (1)
- paperbased (1)
- papierbasiert (1)
- patterning glass microfiber (1)
- polymerase chain reaction (PCR) (1)
- purification (1)
- thermoresponsive (1)
Institute
Viele klinische Schnelltestsysteme benötigen vorpräparierte oder aufgereinigte Analyte mit frisch hergestellten Lösungen. Fernab standardisierter Laborbedingungen wie z.B. in Entwicklungsländern oder Krisengebieten sind solche Voraussetzungen oft nur unter einem hohen Aufwand herstellbar.
Zusätzlich stellt die erforderliche Sensitivität die Entwicklung einfach zu handhabender Testsysteme vor große Herausforderungen.
Autokatalytische Reaktionen, die sich mit Hilfe sehr geringer Initiatorkonzentrationen auslösen lassen, können hier eine Perspektive für Signalverstärkungsprozesse bieten.
Aus diesem Grund wird im ersten Teil der vorliegenden Arbeit das Verhalten der autokatalytischen Arsenit-Jodat-Reaktion in einem mikrofluidischen Kanal untersucht. Dabei werden insbesondere die diffusiven und konvektiven Einflüsse auf die Reaktionskinetik im Vergleich zu makroskopischen Volumenmengen betrachtet.
Im zweiten Teil werden thermoresponsive Hydrogele mit einem kanalstrukturierten Papiernetzwerk zu einem neuartigen, kapillargetriebenen, extern steuerbaren Mikrofluidik-System kombiniert. Das hier vorgestellte Konzept durch Hydrogele ein papierbasiertes LOC-System zu steuern, ermöglicht zukünftig die Herstellung von komplexeren, steuerbaren Point-Of-Care Testsystemen (POCT). Durch z.B. einen thermischen Stimulus, wird das Lösungsverhalten eines Hydrogels so verändert, dass die gespeicherte Flüssigkeit freigesetzt und durch die Kapillarkraft des Papierkanals ins System transportiert wird. Die Eigenschaften dieses Gelnetzwerks können dabei so eingestellt werden, dass eine Freisetzung von Flüssigkeiten sogar bei Körpertemperatur möglich wäre und damit eine Anwendung gänzlich ohne weitere Hilfsmittel denkbar ist. Für die Anwendung notwendige Chemikalien oder Enzyme lassen sich hierbei bequem in getrocknetem Zustand im Papiersubstrat vorlagern und bei Bedarf in Lösung bringen.
Im abschließenden dritten Teil der Arbeit wird ein durch Hydrogele betriebener, Antikörper-basierter Mikroorganismenschnelltest für Escherichia coli präsentiert. Darüber hinaus wird weiterführend eine einfache Methode zur Funktionalisierung eines Hydrogels mit Biomolekülen über EDC/NHS-Kopplung vorgestellt.
Paper-based microfluidics provide an inexpensive, easy to use technology for point-of-care diagnostics in developing countries. Here, we combine paper-based microfluidic devices with responsive hydrogels to add an entire new class of functions to these versatile low-cost fluidic systems. The hydrogels serve as fluid reservoirs. In response to an external stimulus, e.g. an increase in temperature, the hydrogels collapse and release fluid into the structured paper substrate. In this way, chemicals that are either stored on the paper substrate or inside the hydrogel pads can be dissolved, premixed, and brought to reaction to fulfill specific analytic tasks. We demonstrate that multi-step sequences of chemical reactions can be implemented in a paper-based system and operated without the need for external precision pumps. We exemplify this technology by integrating an antibody-based E. coli test on a small and easy to use paper device.
Paper-based microfluidics provide an inexpensive, easy to use technology for point-of-care diagnostics in developing countries. Here, we combine paper-based microfluidic devices with responsive hydrogels to add an entire new class of functions to these versatile low-cost fluidic systems. The hydrogels serve as fluid reservoirs. In response to an external stimulus, e.g. an increase in temperature, the hydrogels collapse and release fluid into the structured paper substrate. In this way, chemicals that are either stored on the paper substrate or inside the hydrogel pads can be dissolved, premixed, and brought to reaction to fulfill specific analytic tasks. We demonstrate that multi-step sequences of chemical reactions can be implemented in a paper-based system and operated without the need for external precision pumps. We exemplify this technology by integrating an antibody-based E. coli test on a small and easy to use paper device.
In this work, the fabrication and characterization of a simple, inexpensive, and effective microfluidic paper analytic device (mu PAD) for monitoring DNA samples is reported. The glass microfiber-based chip has been fabricated by a new wax-based transfer-printing technique and an electrode printing process. It is capable of moving DNA effectively in a time-dependent fashion. The nucleic acid sample is not damaged by this process and is accumulated in front of the anode, but not directly on the electrode. Thus, further DNA processing is feasible. The system allows the DNA to be purified by separating it from other components in sample mixtures such as proteins. Furthermore, it is demonstrated that DNA can be moved through several layers of the glass fiber material. This proof of concept will provide the basis for the development of rapid test systems, e.g., for the detection of pathogens in water samples.
Paper-based microfluidics provide an inexpensive, easy to use technology for point-of-care diagnostics in developing countries. Here, we combine paper-based microfluidic devices with responsive hydrogels to add an entire new class of functions to these versatile low-cost fluidic systems. The hydrogels serve as fluid reservoirs. In response to an external stimulus, e.g. an increase in temperature, the hydrogels collapse and release fluid into the structured paper substrate. In this way, chemicals that are either stored on the paper substrate or inside the hydrogel pads can be dissolved, premixed, and brought to reaction to fulfill specific analytic tasks. We demonstrate that multi-step sequences of chemical reactions can be implemented in a paper-based system and operated without the need for external precision pumps. We exemplify this technology by integrating an antibody-based E. coli test on a small and easy to use paper device.
In this paper, we show experimentally that inside a microfluidic device, where the reactants are segregated, the reaction rate of an autocatalytic clock reaction is accelerated in comparison to the case where all the reactants are well mixed. We also find that, when mixing is enhanced inside the microfluidic device by introducing obstacles into the flow, the clock reaction becomes slower in comparison to the device where mixing is less efficient. Based on numerical simulations, we show that this effect can be explained by the interplay of nonlinear reaction kinetics (cubic autocatalysis) and differential diffusion, where the autocatalytic species diffuses slower than the substrate.
In this paper, we show experimentally that inside a microfluidic device, where the reactants are segregated, the reaction rate of an autocatalytic clock reaction is accelerated in comparison to the case where all the reactants are well mixed. We also find that, when mixing is enhanced inside the microfluidic device by introducing obstacles into the flow, the clock reaction becomes slower in comparison to the device where mixing is less efficient. Based on numerical simulations, we show that this effect can be explained by the interplay of nonlinear reaction kinetics (cubic autocatalysis) and differential diffusion, where the autocatalytic species diffuses slower than the substrate.