Refine
Year of publication
Document Type
- Article (57)
- Postprint (2)
- Conference Proceeding (1)
Language
- English (60)
Is part of the Bibliography
- yes (60)
Keywords
- cyclic voltammetry (3)
- cytochrome c (2)
- 3D electrode structures (1)
- Bioelectrocatalysis (1)
- DMSO (1)
- DNA (1)
- Direct electron transfer (1)
- IR ellipsometry (1)
- Immobilization (1)
- PQQ-GDH (1)
We use substituted polyanilines for the construction of new polymer electrodes for interaction studies with the redox protein cytochrome c (cyt c) and the enzyme sulfite oxidase (SO). For these purposes four different polyaniline copolymers are chemically synthesized. Three of them are copolymers, containing 2-methoxyaniline-5-sulfonic acid with variable ratios of aniline; the fourth copolymer consists of 3-amino-benzoic acid and aniline. The results show that all polymers are suitable for being immobilized as thin stable films on gold wire and indium tin oxide (ITO) electrode surfaces from DMSO solution. This can be demonstrated by cyclic voltammetry and UV-Vis spectroscopy measurements. Moreover, cyt c can be electrochemically detected not only in solution, but also immobilized on top of the polymer films. Furthermore, the appearance of a significant catalytic current has been demonstrated for the sulfonated polyanilines, when the polymer-coated protein electrode is being measured upon addition of sulfite oxidase, confirming the establishment of a bioanalytical signal chain. Best results have been obtained for the polymer with highest sulfonation grade. The redox switching of the polymer by the enzymatic reaction can also be analyzed by following the spectral properties of the polymer electrode.
Cytochrome c was immobilized on screen-printed thick-film gold electrodes by a self-assembly approach using mixed monolayers of mercaptoundecanoic acid and mercaptoundecanol. Cyclic voltammetry revealed quasi-reversible electrochemical behavior of the covalently fixed protein with a formal potential of +10 mV vs. Ag/AgCl. Polarized at +150 mV vs. Ag/AgCl the electrode was found to be sensitive to superoxide radicals in the range 300-1200 nmol L-1. Compared with metal needle electrodes sensitivity and reproducibility could be improved and combined with the easiness of preparation. This allows the fabrication of disposable sensors for nanomolar superoxide concentrations. By changing the electrode potential the sensor can be switched from response to superoxide radicals to hydrogen peroxide-another reactive oxygen species. H2O2 sensitivity can be provided in the range 10-1000 mumol L-1 which makes the electrode suitable for oxidative stress studies