Background: Telerehabilitation can contribute to the maintenance of successful rehabilitation regardless of location and time. The aim of this study was to investigate a specific three-month interactive telerehabilitation routine regarding its effectiveness in assisting patients with physical functionality and with returning to work compared to typical aftercare.
Objective: The aim of the study was to investigate a specific three-month interactive telerehabilitation with regard to effectiveness in functioning and return to work compared to usual aftercare.
Methods: From August 2016 to December 2017, 111 patients (mean 54.9 years old; SD 6.8; 54.3% female) with hip or knee replacement were enrolled in the randomized controlled trial. At discharge from inpatient rehabilitation and after three months, their distance in the 6-minute walk test was assessed as the primary endpoint. Other functional parameters, including health related quality of life, pain, and time to return to work, were secondary endpoints.
Results: Patients in the intervention group performed telerehabilitation for an average of 55.0 minutes (SD 9.2) per week. Adherence was high, at over 75%, until the 7th week of the three-month intervention phase. Almost all the patients and therapists used the communication options. Both the intervention group (average difference 88.3 m; SD 57.7; P=.95) and the control group (average difference 79.6 m; SD 48.7; P=.95) increased their distance in the 6-minute-walk-test. Improvements in other functional parameters, as well as in quality of life and pain, were achieved in both groups. The higher proportion of working patients in the intervention group (64.6%; P=.01) versus the control group (46.2%) is of note.
Conclusions: The effect of the investigated telerehabilitation therapy in patients following knee or hip replacement was equivalent to the usual aftercare in terms of functional testing, quality of life, and pain. Since a significantly higher return-to-work rate could be achieved, this therapy might be a promising supplement to established aftercare.
Research question: The purpose of this study was to evaluate the test-retest reliability of lower extremity kinematics during squat, hip abduction and lunge exercises captured by the Kinect and to evaluate the agreement to a reference 3D camera-based motion system. Methods: Twenty-one healthy individuals performed five repetitions of each lower limb exercise on two different days. Movements were simultaneously assessed by the Kinect and the reference 3D motion system. Joint angles and positions of the lower limb were calculated for sagittal and frontal plane. For the inter-session reliability and the agreement between the two systems standard error of measurement (SEM), bias with limits of agreement (LoA) and Pearson Correlation Coefficient (r) were calculated. Results: Parameters indicated varying reliability for the assessed joint angles and positions and decreasing reliability with increasing task complexity. Across all exercises, measurement deviations were shown especially for small movement amplitudes. Variability was acceptable for joint angles and positions during the squat, partially acceptable during the hip abduction and predominately inacceptable during the lunge. The agreement between systems was characterized by systematic errors. Overestimations by the Kinect were apparent for hip flexion during the squat and hip abduction/adduction during the hip abduction exercise as well as for the knee positions during the lunge. Knee and hip flexion during hip abduction and lunge were underestimated by the Kinect. Significance: The Kinect system can reliably assess lower limb joint angles and positions during simple exercises. The validity of the system is however restricted. An application in the field of early orthopedic rehabilitation without further development of post-processing techniques seems so far limited.
Background
Aim of the study was to find predictors of allocating patients after transcatheter aortic valve implantation (TAVI) to geriatric (GR) or cardiac rehabilitation (CR) and describe this new patient group based on a differentiated characterization.
Methods
From 10/2013 to 07/2015, 344 patients with an elective TAVI were consecutively enrolled in this prospective multicentric cohort study. Before intervention, sociodemographic parameters, echocardiographic data, comorbidities, 6-min walk distance (6MWD), quality of life and frailty (score indexing activities of daily living [ADL], cognition, nutrition and mobility) were documented. Out of these, predictors for assignment to CR or GR after TAVI were identified using a multivariable regression model.
Results
After TAVI, 249 patients (80.7 ± 5.1 years, 59.0% female) underwent CR (n = 198) or GR (n = 51). GR patients were older, less physically active and more often had a level of care, peripheral artery disease as well as a lower left ventricular ejection fraction. The groups also varied in 6MWD. Furthermore, individual components of frailty revealed prognostic impact: higher values in instrumental ADL reduced the probability for referral to GR (OR:0.49, p < 0.001), while an impaired mobility was positively associated with referral to GR (OR:3.97, p = 0.046). Clinical parameters like stroke (OR:0.19 of GR, p = 0.038) and the EuroSCORE (OR:1.04 of GR, p = 0.026) were also predictive.
Conclusion
Advanced age patients after TAVI referred to CR or GR differ in several parameters and seem to be different patient groups with specific needs, e.g. regarding activities of daily living and mobility. Thus, our data prove the eligibility of both CR and GR settings.
Background
Aim of the study was to find predictors of allocating patients after transcatheter aortic valve implantation (TAVI) to geriatric (GR) or cardiac rehabilitation (CR) and describe this new patient group based on a differentiated characterization.
Methods
From 10/2013 to 07/2015, 344 patients with an elective TAVI were consecutively enrolled in this prospective multicentric cohort study. Before intervention, sociodemographic parameters, echocardiographic data, comorbidities, 6-min walk distance (6MWD), quality of life and frailty (score indexing activities of daily living [ADL], cognition, nutrition and mobility) were documented. Out of these, predictors for assignment to CR or GR after TAVI were identified using a multivariable regression model.
Results
After TAVI, 249 patients (80.7 ± 5.1 years, 59.0% female) underwent CR (n = 198) or GR (n = 51). GR patients were older, less physically active and more often had a level of care, peripheral artery disease as well as a lower left ventricular ejection fraction. The groups also varied in 6MWD. Furthermore, individual components of frailty revealed prognostic impact: higher values in instrumental ADL reduced the probability for referral to GR (OR:0.49, p < 0.001), while an impaired mobility was positively associated with referral to GR (OR:3.97, p = 0.046). Clinical parameters like stroke (OR:0.19 of GR, p = 0.038) and the EuroSCORE (OR:1.04 of GR, p = 0.026) were also predictive.
Conclusion
Advanced age patients after TAVI referred to CR or GR differ in several parameters and seem to be different patient groups with specific needs, e.g. regarding activities of daily living and mobility. Thus, our data prove the eligibility of both CR and GR settings.
Ziel der Studie: Die langfristige Nutzung telemedizinischer Angebote hängt nicht nur von deren Wirksamkeit, sondern auch von der Akzeptanz und Zufriedenheit der Patienten ab. Für eine telemedizinische Bewegungstherapie für Patienten nach Implantation einer Knie- oder Hüft-Totalendoprothese und erfolgter Anschlussrehabilitation wurde die Wirksamkeit bereits in einer randomisiert kontrollierten Studie untersucht. Dieser Beitrag fokussiert die Akzeptanz und das Nutzungsverhalten der Patienten hinsichtlich des eingesetzten telerehabilitativen Systems.
Methodik: Zur Erfassung der Technikakzeptanz wurden 48 Patienten (53±7 Jahre; 26 Frauen; 35 Hüft-/13 Knie-TEP) im Anschluss an eine dreimonatige telemedizinische Bewegungstherapie mittels des Telehealth Usability Questionnaire befragt. Der Fragebogen besteht aus 21 Items (siebenstufige Likert-Skala) in sechs Skalen (z. B. Nützlichkeit, Qualität der Interaktionen, Verlässlichkeit). In einer zusätzlichen Skala wurden systemspezifische Fragen zusammengefasst. Die Ergebnisse wurden als Skalenprozent (100 ≙ vollkommene Zustimmung) dargestellt. Das Nutzungsverhalten wurde anhand systemgenerierter Prozessdaten zum Training sowie zu integrierten Sprach-/Textnachrichten untersucht.
Ergebnisse: Die TUQ-Skalen „Nützlichkeit“ (Mdn 95,2) sowie „Benutzerfreundlichkeit und Erlernbarkeit“ (Mdn 92,9) wurden am höchsten bewertet, während die „Verlässlichkeit“ (Mdn 57,1) und „Qualität der Interaktionen“ (Mdn 71,4) die geringsten Ausprägungen zeigten. Die systemspezifische Skala wurde im oberen Quartil eingeordnet (Mdn 85,7).
In der ersten Woche führten 39 Patienten (81%), in der zweiten 45 Patienten (94%) mindestens eine Trainingsübung mit dem System durch. Der Anteil aktiver Patienten (≥1 Übung/Woche) reduzierte sich im weiteren Verlauf auf 75% (n=36) in der 7. Woche und 48% (n=23) in der 12. Woche. Die systemeigenen Kommunikationsmöglichkeiten wurden nach Therapiestart zunächst häufig genutzt: in der ersten Woche sendeten 42 Patienten (88%) Nachrichten, 47 Patienten (98%) erhielten Nachrichten von ihrem Therapeuten. In der 7. Woche sendeten/erhielten 9 (19%) bzw. 13 (27%) Patienten Nachrichten über das System.
Schlussfolgerung: Die Patienten nahmen die telemedizinische Bewegungstherapie überwiegend als nützlich und benutzerfreundlich wahr und schienen im Wesentlichen mit dem System zufrieden, das sich damit für den kurzfristigen Einsatz von 6 bis 8 Wochen im Anschluss an eine Anschlussrehabilitation als gut geeignet zeigte.
Background
Elderly patients are a growing population in cardiac rehabilitation (CR). As postural control declines with age, assessment of impaired balance is important in older CR patients in order to predict fall risk and to initiate counteracting steps. Functional balance tests are subjective and lack adequate sensitivity to small differences, and are further subject to ceiling effects. A quantitative approach to measure postural control on a continuous scale is therefore desirable. Force plates are already used for this purpose in other clinical contexts, therefore could be a promising tool also for older CR patients. However, in this population the reliability of the assessment is not fully known.
Research question
Analysis of test-retest reliability of center of pressure (CoP) measures for the assessment of postural control using a force plate in older CR patients.
Methods
156 CR patients (> 75 years) were enrolled. CoP measures (path length (PL), mean velocity (MV), and 95% confidence ellipse area (95CEA)) were analyzed twice with an interval of two days in between (bipedal narrow stance, eyes open (EO) and closed (EC), three trials for each condition, 30 s per trial), using a force plate. For test-retest reliability estimation absolute differences (& UDelta;: T0-T1), intraclass correlation coefficients (ICC) with 95% confidence intervals, standard error of measurement and minimal detectable change were calculated.
Results
Under EO condition ICC were excellent for PL and MV (0.95) and good for 95CEA (0.88) with & UDelta; of 10.1 cm (PL), 0.3 cm/sec (MV) and 1.5 cm(2 )(95CEA) respectively. Under EC condition ICC were excellent (> 0.95) for all variables with larger & UDelta; (PL: 21.7 cm; MV: 0.7 cm/sec; 95CEA: 2.4 cm(2))
Significance
In older CR patients, the assessment of CoP measures using a force plate shows good to excellent test retest reliability.