Refine
Has Fulltext
- yes (25)
Year of publication
Document Type
- Postprint (25) (remove)
Language
- English (25) (remove)
Keywords
- LIBS (4)
- Diodenlaserspektroskopie (3)
- Fluoreszenz-Resonanz-Energie-Transfer (3)
- Immunoassay (3)
- Kohlendioxid (3)
- Energietransfer (2)
- Isotopenverhältnis (2)
- Lumineszenz (2)
- PCA (2)
- Quantenpunkt (2)
Institute
- Institut für Chemie (23)
- Extern (4)
- Institut für Biochemie und Biologie (1)
The performance of a home-built tunable diode laser (TDL) spectrometer has been optimized regarding multi-line detection of carbon dioxide in natural gases. In the regime of the (30<SUP>0</SUP>1)<SUB>III</SUB> ← (000) band of <SUP>12</SUP>CO<SUB>2</SUB> around 1.6 μm, the dominating isotope species <SUP>12</SUP>CO<SUB>2</SUB>, <SUP>13</SUP>CO<SUB>2</SUB>, and <SUP>12</SUP>C<SUP>18</SUP>O<SUP>16</SUP>O were detected simultaneously. In contrast to most established techniques, selective measurements are performed without any sample preparation. This is possible since the CO<SUB>2</SUB> detection is free of interference from water, ubiquitous in natural gases. Detection limits in the range of a few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. Linear calibration plots cover a dynamic range of four orders of magnitude, allowing for quantitative CO<SUB>2</SUB> detection in various samples, like soil and breath gas. High isotopic resolution enables the excellent selectivity, sensitivity, and stability of the chosen analytical concept. The obtained isotopic resolution of typically ± 1.0 ‰ and ± 1.5 ‰ (for 3 vol. % and 0.7 vol. % of CO<SUB>2</SUB>, respectively) offers a promising analytical tool for isotope-ratio determination of carbon dioxide in soil gas. Preliminary experiments on soil respiration for the first time combine the on-line quantification of the overall carbon dioxide content with an optode sensor and isotopic determination (TDL system) of natural gas species.
Near-infrared (NIR) absorption spectroscopy with tunable diode lasers allows the simultaneous detection of the three most important isotopologues of carbon dioxide (<SUP>12</SUP>CO<SUB>2</SUB>, <SUP>13</SUP>CO<SUB>2</SUB>, <SUP>12</SUP>C<SUP>18</SUP>O<SUP>16</SUP>O) and carbon monoxide (<SUP>12</SUP>CO, <SUP>13</SUP>CO, <SUP>12</SUP>C<SUP>18</SUP>O). The flexible and compact fiber-optic tunable diode laser absorption spectrometer (TDLAS) allows selective measurements of CO<SUB>2</SUB> and CO with high isotopic resolution without sample preparation since there is no interference with water vapour. For each species, linear calibration plots with a dynamic range of four orders of magnitude and detection limits (LOD) in the range of a few ppm were obtained utilizing wavelength modulation spectroscopy (WMS) with balanced detection in a Herriott-type multipass cell. The high performance of the apparatus is illustrated by fill-evacuation-refill cycles.
Absorption and fluorescence properties of 4 hydraulic oils (3 biological and 1 petroleum-based) were investigated. In-situ LIF (laser-induced fluorescence) analysis of the oils on a brown sandy loam soil was performed. With calibration, quantitative detection was achieved. Estimated limits of detection were below ca. 500 mg/kg for the petroleum-based oil and ca. 2000 mg/kg for one biological oil. A semi-quantitative classification scheme is proposed for monitoring of the biological oils. This approach was applied to investigate the migration of a biological oil in soil-containing compartments, namely a soil column and a soil bed.
Two examples of our biophotonic research utilizing nanoparticles are presented, namely laser-based fluoroimmuno analysis and in-vivo optical oxygen monitoring. Results of the work include significantly enhanced sensitivity of a homogeneous fluorescence immunoassay and markedly improved spatial resolution of oxygen gradients in root nodules of a legume species.
The drift time spectra of polycyclic aromatic hydrocarbons (PAH), alkylbenzenes and alkylphenylethers were recorded with a laser-based ion mobility (IM) spectrometer. The ion mobilities of all compounds were determined in helium as drift gas. This allows the calculation of the diffusion cross sections (Omegacalc) on the basis of the exact hard sphere scattering model (EHSSM) and their comparison with the experimentally determined diffusion cross sections (Omegaexp). These Omegaexp/Omegacalc-correlations are presented for molecules with a rigid structure like PAH and prove the reliability of the theoretical model and experimental method. The increase of the selectivity of IM spectrometry is demonstrated using resonance enhanced multiphoton ionisation (REMPI) at atmospheric pressure, realized by tuneable lasers. The REMPI spectra of nine alkylbenzenes and alkylphenylethers are investigated. On the basis of these spectra, the complete qualitative distinction of eight compounds in a mixture is shown. These experiments are extended to alkylbenzene isomer mixtures.
Continuous synthesis of pyridocarbazoles and initial photophysical and bioprobe characterization
(2013)
Pyridocarbazoles when ligated to transition metals yield high affinity kinase inhibitors. While batch photocyclizations enable the synthesis of these heterocycles, the non-oxidative Mallory reaction only provides modest yields and difficult to purify mixtures. We demonstrate here that a flow-based Mallory cyclization provides superior results and enables observation of a clear isobestic point. The flow method allowed us to rapidly synthesize ten pyridocarbazoles and for the first time to document their interesting photophysical attributes. Preliminary characterization reveals that these molecules might be a new class of fluorescent bioprobe.
Hemolysis, the rupturing of red blood cells, can result from numerous medical conditions (in vivo) or occur after collecting blood specimen or extracting plasma and serum out of whole blood (in vitro). In clinical laboratory practice, hemolysis can be a serious problem due to its potential to bias detection of various analytes or biomarkers. Here we present the first ‘‘mix-and-measure’’ method to assess the degree of hemolysis in biosamples using luminescence spectroscopy. Luminescent terbium complexes (LTC) were studied in the presence of free hemoglobin (Hb) as indicators for hemolysis in TRIS-buffer, and in fresh human plasma with absorption, excitation and emission measurements. Our findings indicate dynamic as well as resonance energy transfer (FRET) between the LTC and the porphyrin ligand of hemoglobin. This transfer leads to a decrease in luminescence intensity and decay time even at nanomolar hemoglobin concentrations either in buffer or plasma. Luminescent terbium complexes are very sensitive to free hemoglobin in buffer and blood plasma. Due to the instant change in luminescence properties of the LTC in presence of Hb it is possible to access the concentration of hemoglobin via spectroscopic methods without incubation time or further treatment of the sample thus enabling a rapid and sensitive detection of hemolysis in clinical diagnostics.
Improvement of a fluorescence immunoassay with a compact diode-pumped solid state laser at 315 nm
(2006)
We demonstrate the improvement of fluorescence immunoassay (FIA) diagnostics in deploying a newly developed compact diode-pumped solid state (DPSS) laser with emission at 315 nm. The laser is based on the quasi-three-level transition in Nd:YAG at 946 nm. The pulsed operation is either realized by an active Q-switch using an electro-optical device or by introduction of a Cr<SUP>4+</SUP>:YAG saturable absorber as passive Q-switch element. By extra-cavity second harmonic generation in different nonlinear crystal media we obtained blue light at 473 nm. Subsequent mixing of the fundamental and the second harmonic in a β-barium-borate crystal provided pulsed emission at 315 nm with up to 20 μJ maximum pulse energy and 17 ns pulse duration. Substitution of a nitrogen laser in a FIA diagnostics system by the DPSS laser succeeded in considerable improvement of the detection limit. Despite significantly lower pulse energies (7 μJ DPSS laser versus 150 μJ nitrogen laser), in preliminary investigations the limit of detection was reduced by a factor of three for a typical FIA.
Investigations with frequency domain photon density waves allow elucidation of absorption and scattering properties of turbid media. The temporal and spatial propagation of intensity modulated light with frequencies up to more than 1 GHz can be described by the P1 approximation to the Boltzmann transport equation. In this study, we establish requirements for the appropriate choice of turbid model media and characterize mixtures of isosulfan blue as absorber and polystyrene beads as scatterer. For these model media, the independent determination of absorption and reduced scattering coefficients over large absorber and scatterer concentration ranges is demonstrated with a frequency domain photon density wave spectrometer employing intensity and phase measurements at various modulation frequencies.
The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text