Refine
Year of publication
Language
- English (47)
Is part of the Bibliography
- yes (47)
Keywords
- ultrafast X-ray diffraction (2)
- Detector modelling and simulations II (electric fields, charge transport, multiplication and induction, pulse formation, electron emission, etc) (1)
- Energy-dispersive Laue diffraction (1)
- Interaction of radiation with matter (1)
- Solid state detectors (1)
- X-ray diffraction (1)
- X-ray imaging (1)
- X-ray spectroscopy (1)
- X-ray switching (1)
- acoustic waves (1)
Institute
We present ultrafast x-ray diffraction (UXRD) experiments on different photoexcited oxide superlattices. All data are successfully simulated by dynamical x-ray diffraction calculations based on a microscopic model, that accounts for the linear response of phonons to the excitation laser pulse. Some Bragg reflections display a highly nonlinear strain dependence. The origin of linear and two distinct nonlinear response phenomena is discussed in a conceptually simpler model using the interference of envelope functions that describe the diffraction efficiency of the average constituent nanolayers. The combination of both models facilitates rapid and accurate simulations of UXRD experiments.
We study gadolinium thin films as a model system for ferromagnets with negative thermal expansion. Ultrashort laser pulses heat up the electronic subsystem and we follow the transient strain via ultrafast x-ray diffraction. In terms of a simple Grueneisen approach, the strain is decomposed into two contributions proportional to the thermal energy of spin and phonon subsystems. Our analysis reveals that upon femtosecond laser excitation, phonons and spins can be driven out of thermal equilibrium for several nanoseconds.
We investigate the heat transport through a rare earth multilayer system composed of yttrium (Y), dysprosium (Dy), and niobium (Nb) by ultrafast x-ray diffraction. This is an example of a complex heat flow problem on the nanoscale, where several different quasiparticles carry the heat and conserve a nonequilibrium for more than 10 ns. The Bragg peak positions of each layer represent layer-specific thermometers that measure the energy flow through the sample after excitation of the Y top layer with fs-laser pulses. In an experiment-based analytic solution to the nonequilibrium heat transport problem, we derive the individual contributions of the spins and the coupled electron-lattice system to the heat conduction. The full characterization of the spatiotemporal energy flow at different starting temperatures reveals that the spin excitations of antiferromagnetic Dy speed up the heat transport into the Dy layer at low temperatures, whereas the heat transport through this layer and further into the Y and Nb layers underneath is slowed down. The experimental findings are compared to the solution of the heat equation using macroscopic temperature-dependent material parameters without separation of spin and phonon contributions to the heat. We explain why the simulated energy density matches our experiment-based derivation of the heat transport, although the simulated thermoelastic strain in this simulation is not even in qualitative agreement.
Energy-dispersive X-ray reflectivity and GID for real-time growth studies of pentacene thin films
(2007)
We use energy-dispersive X-ray reflectivity and grazing incidence diffraction (GID) to follow the growth of the crystalline organic semiconductor pentacene on silicon oxide in-situ and in real-time. The technique allows for monitoring Bragg reflections and measuring X-ray growth oscillations with a time resolution of 1 min in a wide q-range in reciprocal space extending over 0.25-0.80 angstrom(-1), i.e. sampling a large number of Fourier components simultaneously. A quantitative analysis of growth oscillations at several q-points yields the evolution of the surface roughness, showing a marked transition from layer-by-layer growth to strong roughening after four monolayers of pentacene have been deposited. (c) 2006 Elsevier B.V. All rights reserved.
Simultaneous dynamic characterization of charge and structural motion during ferroelectric switching
(2017)
Monitoring structural changes in ferroelectric thin films during electric field induced polarization switching is important for a full microscopic understanding of the coupled motion of charges, atoms, and domainwalls in ferroelectric nanostructures. We combine standard ferroelectric test sequences of switching and nonswitching electrical pulses with time-resolved x-ray diffraction to investigate the structural response of a nanoscale Pb(Zr0.2Ti0.8)O-3 ferroelectric oxide capacitor upon charging, discharging, and polarization reversal. We observe that a nonlinear piezoelectric response of the ferroelectric layer develops on a much longer time scale than the RC time constant of the device. The complex atomic motion during the ferroelectric polarization reversal starts with a contraction of the lattice, whereas the expansive piezoelectric response sets in after considerable charge flow due to the applied voltage pulses on the electrodes of the capacitor. Our simultaneous measurements on a working device elucidate and visualize the complex interplay of charge flow and structural motion and challenges theoretical modeling.
The first application of a pnCCD detector for X-ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two-dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse-resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution Delta E/E similar or equal to 10(-2). a three-dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so-called single-photon- counting mode. A full dataset was evaluated taking into account all photons recorded within 10(5) detector frames at a readout rate of 200 Hz. By representing the data in reciprocal-space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.
Experiments using a simple X-ray interferometer to measure the degree of spatial coherence of hard X-rays are reported. A monolithic Fresnel bimirror is used at small incidence angles to investigate synchrotron radiation in the energy interval 5-50 keV with monochromatic and white beam. The experimental setup was equivalent to a Young's double-slit experiment for hard X-rays with slit dimensions in the micrometre range. From the high-contrast interference pattern the degree of coherence was determined.
This paper discusses the experimental realisation of two types of X-ray interferometer based on pinhole diffraction. In both interferometers the beam splitter was a thin metal foil containing micrometer pinholes to divide the incident X-ray wave into two coherent waves. The interference pattern was studied using an energy-dispersive detector to simultaneously investigate in a large spectral range the diffraction properties of the white synchrotron radiation. For a highly absorbing pinhole mask the interference fringes from the classical Young's double-pinhole experiment were recorded and the degree of coherence of X-rays could be determined. In the case of low absorption of the metal foil at higher X-ray energies (> 15 keV) the interference pattern of a point diffraction interferometer was observed using the same set-up. The spectral refraction index of the metal foil was determined
We present a setup for ultrafast x-ray diffraction (UXRD) based at the storage ring BESSY II, in particular, a pump laser that excites the sample using 250 fs laser-pulses at repetition rates ranging from 208 kHz to 1.25 MHz. We discuss issues connected to the high heat-load and spatio-temporal alignment strategies in the context of a UXRD experiment at high repetition rates. The spatial overlap between laser pump and x-ray probe pulse is obtained with 10 mu m precision and transient lattice changes can be recorded with an accuracy of delta a/a(0) = 10(-6). We also compare time-resolved x-ray diffraction signals from a laser excited LSMO/STO superlattice with phonon dynamics simulations. From the analysis we determine the x-ray pulse duration to 120 ps in standard operation mode and below 10 ps in low-alpha mode.