Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports.
This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.
Achilles (AT) and patellar tendons (PT) are commonly affected by tendinopathy in adult athletes but prevalence of symptoms and morphological changes in adolescents is unclear. The study aimed to determine prevalence of tendinopathy and intratendinous changes in ATs and PTs of adolescent athletes. A total of 760 adolescent athletes (13.0 +/- 1.9 years; 160 +/- 13cm; 50 +/- 14kg) were examined. History, local clinical examination, and longitudinal Doppler ultrasound analysis for both ATs and PTs were performed including identification of intratendinous echoic changes and vascularization. Diagnosis of tendinopathy was complied clinically in case of positive history of tendon pain and tendon pain on palpation. Achilles tendinopathy was diagnosed in 1.8% and patellar tendinopathy in 5.8%. Vascularizations were visible in 3.0% of ATs and 11.4% of PTs, hypoechogenicities in 0.7% and 3.2% as well as hyperechogenicities in 0% and 0.3%, respectively. Vascularizations and hypoechogenicities were statistically significantly more often in males than in females (P0.02). Subjects with patellar tendinopathy had higher prevalence of structural intratendinous changes than those without PT symptoms (P0.001). In adolescent athletes, patellar tendinopathy is three times more frequent compared with Achilles tendinopathy. Longitudinal studies are necessary to investigate physiological or pathological origin of vascularizations and its predictive value in development of tendinopathy.
Tendinopathies are frequently the cause of chronic, load-dependent complaints of the lower extremity. Commonly, the large tendons of the ankle and knee joints are affected, especially the Achilles and patellar tendons. Repeated overuse in sports and/or daily activities is assumed as the aetiology. Besides the clinical examination including a comprehensive anamnesis of pain and training/loading, sonographic imaging has a high training/loading relevance for the diagnosis of tendon pathologies of the lower extremity. Training concepts are considered in first line as the treatment of choice. A combination with physical therapy interventions can be useful. In cases of a more severe pathology and long-standing complaints multimodal therapeutic options should be employed. The use of surgical treatment procedures should only be taken into account in case of failed response to conservative treatment.
Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation.
Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm.
Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.