Refine
Year of publication
Document Type
- Article (123)
- Postprint (4)
- Monograph/Edited Volume (1)
- Part of a Book (1)
- Doctoral Thesis (1)
Keywords
- Bioelectrocatalysis (5)
- Direct electron transfer (5)
- Biosensors (4)
- bioelectrocatalysis (4)
- Aldehyde oxidoreductase (3)
- Biosensor (3)
- Cytochrome P450 (3)
- Nanoparticles (3)
- electron transfer (3)
- hydrogen peroxide (3)
CYP106A2 is one of only a few known steroid hydroxylases of bacterial origin, which might be interesting for biotechnological applications. Despite the enzyme having been studied for more than 30 years, its physiological function remains elusive. To date, there have been no reports of the redox potential of CYP106A2, which was supposed to be unusually low for a cytochrome P450. In this work we show that cyclic voltammetry is not only suitable to determine the redox potential of challenging proteins such as CYP106A2, measured at - 128 mV vs. NHE, but also to study molecular interactions of the enzyme with different interaction partners via the respective electrochemical responses. The effect of small ligands, such as carbon monoxide and cyanide, was observed on the cyclic voltammograms of CYP106A2. Furthermore, we found that Tween 80 caused a positive shift of the redox potential of immobilised CYP106A2 indicative for water expulsion from the haem environment. Moreover, electron transfer mediation phenomena with biological redox partners (e.g. ferredoxins) were studied. Finally, the influence of two different kinds of substrates on the electrochemical response of CYP106A2 was assessed, aligning observations from spectral and electrochemical studies.
Surface modification with thermoresponsive polymer brushes for a switchable electrochemical sensor
(2014)
Elaboration of switchable surfaces represents an interesting way for the development of a new generation of electrochemical sensors. In this paper, a method for growing thermoresponsive polymer brushes from a gold surface pre-modified with polyethyleneimine (PEI), subsequent layer-by-layer polyelectrolyte assembly and adsorption of a charged macroinitiator is described. We propose an easy method for monitoring the coil-to-globule phase transition of the polymer brush using an electrochemical quartz crystal microbalance with dissipation (E-QCM-D). The surface of these polymer modified electrodes shows reversible switching from the swollen to the collapsed state with temperature. As demonstrated from E-QCM-D measurements using an original signal processing method, the switch is operating in three reversible steps related to different interfacial viscosities. Moreover, it is shown that the one electron oxidation of ferrocene carboxylic acid is dramatically affected by the change from the swollen to the collapsed state of the polymer brush, showing a spectacular 86% decrease of the charge transfer resistance between the two states.
Surface modification with thermoresponsive polymer brushes for a switchable electrochemical sensor
(2014)
Elaboration of switchable surfaces represents an interesting way for the development of a new generation of electrochemical sensors. In this paper, a method for growing thermoresponsive polymer brushes from a gold surface pre-modified with polyethyleneimine (PEI), subsequent layer-by-layer polyelectrolyte assembly and adsorption of a charged macroinitiator is described. We propose an easy method for monitoring the coil-to-globule phase transition of the polymer brush using an electrochemical quartz crystal microbalance with dissipation (E-QCM-D). The surface of these polymer modified electrodes shows reversible switching from the swollen to the collapsed state with temperature. As demonstrated from E-QCM-D measurements using an original signal processing method, the switch is operating in three reversible steps related to different interfacial viscosities. Moreover, it is shown that the one electron oxidation of ferrocene carboxylic acid is dramatically affected by the change from the swollen to the collapsed state of the polymer brush, showing a spectacular 86% decrease of the charge transfer resistance between the two states.
The control of bioelectrocatalytic processes by external stimuli for the indirect detection of non-redox active species was achieved using an esterase and a redox enzyme both integrated within a redox hydrogel. The poly( vinyl) imidazole Os(bpy)(2)Cl hydrogel displays pH-responsive properties. The esterase catalysed reaction leads to a local pH decrease causing protonation of imidazole moieties thus increasing hydrogel solvation and mobility of the tethered Os-complexes. This is the key step to enable improved electron transfer between an aldehyde oxidoreductase and the polymer-bound Os-complexes. The off-on switch is further integrated in a biofuel cell system for self-powered signal generation.
Wastewater samples from a Swedish chemi-thermo-mechanical pulp (CTMP) mill collected at different purification stages in a wastewater treatment plant (WWTP) were analyzed with an amperometric enzyme-based biosensor array in a flow-injection system. In order to resolve the complex composition of the wastewater, the array consists of several sensing elements which yield a multidimensional response. We used principal component analysis (PCA) to decompose the array's responses, and found that wastewater with different degrees of pollution can be differentiated. With the help of partial least squares regression (PLS-R), we could link the sensor responses to the toxicity parameter, as well as to global organic pollution parameters (COD, BOD, and TOC). From investigating the influences of individual sensors in the array, it was found that the best models were in most cases obtained when all sensors in the array were included in the PLS-R model. We find that fast simultaneous determination of several global environmental parameters characterizing wastewaters is possible with this kind of biosensor array, in particular because of the link between the sensor responses and the biological effect onto the ecosystem into which the wastewater would be released. In conjunction with multivariate data analysis tools, there is strong potential to reduce the total time until a result is yielded from days to a few minutes.
Dendritic polyglycerol-poly(ethylene glycol)-based polymer networks for biosensing application
(2014)
This work describes the formation of a new dendritic polyglycerol-poly(ethylene glycol)-based 3D polymer network as a matrix for immobilization of the redox enzyme periplasmatic aldehyde oxidoreductase to create an electrochemical biosensor. The novel network is built directly on the gold surface, where it simultaneously stabilizes the enzyme for up to 4 days. The prepared biosensors can be used for amperometric detection of benzaldehyde in the range of 0.8-400 mu M.
Microelectrodes modified with electropolymerized plumbagin (PLG) were used for the generation of superoxide radical (O-2(center dot-)) and hydrogen peroxide (H2O2) during oxygen reduction reaction (ORR) in an aqueous medium, specifically in serum-free cell culture media. This is enabled by the specific design of a polymer film on the microelectrode. The generation and diffusion of O-2(center dot-) during electrocatalytic ORR at a positionable PLG polymer-modified microelectrode was followed by fluorescence microscopy with the selective dye 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) and by amperometric detection using a cytochrome c-modified electrode at + 0.13 V. H2O2 production, either by direct oxygen reduction or as product of O-2(center dot-) disproportionation, was monitored by the reaction with Amplex UltraRed. The PLG polymer-modified microelectrodes were used to expose mammalian B6-RPE07 retinal cells to defined local fluxes of reactive oxygen species (ROS), and cellular responses and morphological alterations were observed. The use of a controllable source of ROS opens many possibilities to study how living cells respond to the presence of a certain flux of specific ROS.
In this paper we report immobilization and bioelectrocatalysis of human sulfite oxidase (hSO) on nanostructured antimony doped tin oxide (ATO) thin film electrodes. Two types of ATO thin film electrodes were prepared via evaporation induced self-assembly of ATO nanoparticle sols. The use of a porogen results in different porosity and film thickness. Nevertheless both electrode types reveal similar quasi reversible electrochemical behavior for positive and negatively charged small mediators. Facile and durable immobilization of catalytically active enzyme in a direct electron transfer configuration was achieved without further chemical modification of the ATO surfaces. Interestingly, the binding of hSO onto the ATO surface seems to be not only of electrostatic nature, but also originates from a strong interaction between the histidine-tag of the enzyme and the supporting material. This is suggested from stable sulfite dependent bioelectrocatalytic signals at high ionic strength and imidazole desorption experiments. As such, ATO appears as a promising conductive platform for the immobilization of complex enzymes and their application in bioelectrocatalysis. (C) 2013 Elsevier Ltd. All rights reserved.
The present work contributes to the development of reusable sensing systems with a visual evaluation of the detection process related to an analyte. An electrochemical switchable protein-based optical device was designed with the core part composed of cytochrome c immobilized in a mesoporous indium tin oxide film. A color-developing redox-sensitive dye was used as switchable component of the system. The cytochrome c-catalyzed oxidation of the dye by hydrogen peroxide is spectroscopically investigated. When the dye is co-immobilized with the protein, its redox state is easily controlled by application of an electrical potential at the supporting material. This enables to electrochemically reset the system to the initial state and repetitive signal generation. The implemented reset function of the color forming reaction will make calibration of small test devices possible. The principle can be extended to other color forming redox reactions and to coupled enzyme systems, such as rapid food testing and indication of critical concentrations of metabolites for health care.
The present study reports a facile approach for sulfite biosensing, based on enhanced direct electron transfer of a human sulfite oxidase (hSO) immobilized on a gold nanoparticles modified electrode. The spherical core shell AuNPs were prepared via a new method by reduction of HAuCl4 with branched poly(ethyleneimine) in an ionic liquids resulting particles with a diameter less than 10 nm. These nanoparticles were covalently attached to a mercaptoundecanoic acid modified Au-electrode where then hSO was adsorbed and an enhanced interfacial electron transfer and electrocatalysis was achieved. UV/Vis and resonance Raman spectroscopy, in combination with direct protein voltammetry, are employed for the characterization of the system and reveal no perturbation of the structural integrity of the redox protein. The proposed biosensor exhibited a quick steady-state current response, within 2 s, a linear detection range between 0.5 and 5.4 mu M with a high sensitivity (1.85 nA mu M-1). The investigated system provides remarkable advantages in the possibility to work at low applied potential and at very high ionic strength. Therefore these properties could make the proposed system useful in the development of bioelectronic devices and its application in real samples.