Refine
Has Fulltext
- no (3)
Year of publication
- 2012 (3) (remove)
Document Type
- Article (3)
Language
- English (3)
Is part of the Bibliography
- yes (3)
Keywords
- Progesterone (2)
- Amperometry (1)
- Biosensors (1)
- Cytochrome P450 (1)
- Ferrocene (1)
- Hybridoma (1)
- Immunoassay (1)
- Phenolic substances (1)
- Protein G (1)
- SLPI (1)
Institute
The aromatic peroxygenase (APO; EC 1.11.2.1) from the agraric basidomycete Marasmius rotula (MroAPO) immobilized at the chitosan-capped gold-nanoparticle-modified glassy carbon electrode displayed a pair of redox peaks with a midpoint potential of -278.5 mV vs. AgCl/AgCl (1 M KCl) for the Fe(2+)/Fe(3+) redox couple of the heme-thiolate-containing protein. MroAPO oxidizes aromatic substrates such as aniline, p-aminophenol, hydroquinone, resorcinol, catechol, and paracetamol by means of hydrogen peroxide. The substrate spectrum overlaps with those of cytochrome P450s and plant peroxidases which are relevant in environmental analysis and drug monitoring. In M. rotula peroxygenase-based enzyme electrodes, the signal is generated by the reduction of electrode-active reaction products (e.g., p-benzoquinone and p-quinoneimine) with electro-enzymatic recycling of the analyte. In these enzyme electrodes, the signal reflects the conversion of all substrates thus representing an overall parameter in complex media. The performance of these sensors and their further development are discussed.
The large scale production of a monoclonal anti-progesterone antibody in serum free medium followed by affinity chromatography on protein G lead to a contamination of the antibody sample with a protein of about 14 kDa. This protein was identified by mass spectrometry as secretory leukocyte protease inhibitor (SLPI). This SLPI contamination lead to a failure of the fiber-optic based competitive fluorescence assay to detect progesterone in milk. Purification of the monoclonal antibody using protein A columns circumvented this problem.
A direct competitive homogeneous immunoassay for progesterone - the Redox Quenching Immunoassay
(2012)
A direct competitive amperometric immunoassay format for the detection of haptens and proteins was developed. The method is based on the quenching of electroactivity of ferrocenium, which is coupled to the antigen and used as the primary reporter, upon binding to a monoclonal anti-ferrocenium antibody, which is coupled to the detection antibody and used as a secondary reporter. A separation-free progesterone immunoassay with a lower detection limit of 1 ng?mL-1 (3.18 nmol?L-1) in 1?:?2 diluted blood serum was realised by combining two bifunctional conjugates, a ferrocenium-PEG-progesterone tracer and a bioconjugate of one anti-progesterone and one anti-ferrocenium antibody. The immune complex is formed within 30 s upon addition of progesterone, resulting in a total analysis time of 1.5 min.