Life on Earth is diverse and ranges from unicellular organisms to multicellular creatures like humans. Although there are theories about how these organisms might have evolved, we understand little about how ‘life’ started from molecules. Bottom-up synthetic biology aims to create minimal cells by combining different modules, such as compartmentalization, growth, division, and cellular communication.
All living cells have a membrane that separates them from the surrounding aqueous medium and helps to protect them. In addition, all eukaryotic cells have organelles that are enclosed by intracellular membranes. Each cellular membrane is primarily made of a lipid bilayer with membrane proteins. Lipids are amphiphilic molecules that assemble into molecular bilayers consisting of two leaflets. The hydrophobic chains of the lipids in the two leaflets face each other, and their hydrophilic headgroups face the aqueous surroundings. Giant unilamellar vesicles (GUVs) are model membrane systems that form large compartments with a size of many micrometers and enclosed by a single lipid bilayer. The size of GUVs is comparable to the size of cells, making them good membrane models which can be studied using an optical microscope. However, after the initial preparation, GUV membranes lack membrane proteins which have to be reconstituted into these membranes by subsequent preparation steps. Depending on the protein, it can be either attached via anchor lipids to one of the membrane leaflets or inserted into the lipid bilayer via its transmembrane domains.
The first step is to prepare the GUVs and then expose them to an exterior solution with proteins. Various protocols have been developed for the initial preparation of GUVs. For the second step, the GUVs can be exposed to a bulk solution of protein or can be trapped in a microfluidic device and then supplied with the protein solution. To minimize the amount of solution and for more precise measurements, I have designed a microfluidic device that has a main channel, and several dead-end side channels that are perpendicular to the main channel. The GUVs are trapped in the dead-end channels. This design exchanges the solution around the GUVs via diffusion from the main channel, thus shielding the GUVs from the flow within the main channel. This device has a small volume of just 2.5 μL, can be used without a pump and can be combined with a confocal microscope, enabling uninterrupted imaging of the GUVs during the experiments. I used this device for most of the experiments on GUVs that are discussed in this thesis.
In the first project of the thesis, a lipid mixture doped with an anchor lipid was used that can bind to a histidine chain (referred to as His-tag(ged) or 6H) via the metal cation Ni2+. This method is widely used for the biofunctionalization of GUVs by attaching proteins without a transmembrane domain. Fluorescently labeled His-tags which are bound to a membrane can be observed in a confocal microscope. Using the same lipid mixture, I prepared the GUVs with different protocols and investigated the membrane composition of the resulting GUVs by evaluating the amount of fluorescently labeled His-tagged molecules bound to their membranes. I used the microfluidic device described above to expose the outer leaflet of the vesicle to a constant concentration of the His-tagged molecules. Two fluorescent molecules with a His-tag were studied and compared: green fluorescent protein (6H-GFP) and fluorescein isothiocyanate (6H-FITC). Although the quantum yield in solution is similar for both molecules, the brightness of the membrane-bound 6H-GFP is higher than the brightness of the membrane-bound 6H-FITC. The observed difference in the brightness reveals that the fluorescence of the 6H-FITC is quenched by the anchor lipid via the Ni2+ ion. Furthermore, my measurements also showed that the fluorescence intensity of the membranebound His-tagged molecules depends on microenvironmental factors such as pH. For both 6H-GFP and 6H-FITC, the interaction with the membrane is quantified by evaluating the equilibrium dissociation constant. The membrane fluorescence is measured as a function of the fluorophores’ molar concentration. Theoretical analysis of these data leads to the equilibrium dissociation constants of (37.5 ± 7.5) nM for 6H-GFP and (18.5 ± 3.7) nM for 6H-FITC.
The anchor lipid mentioned previously used the metal cation Ni2+ to mediate the bond between the anchor lipid and the His-tag. The Ni2+ ion can be replaced by other transition metal ions. Studies have shown that Co3+ forms the strongest bonds with the His-tags attached to proteins. In these studies, strong oxidizing agents were used to oxidize the Co2+ mediated complex with the His-tagged protein to a Co3+ mediated complex. This procedure puts the proteins at risk of being oxidized as well. In this thesis, the vesicles were first prepared with anchor lipids without any metal cation. The Co3+ was added to these anchor lipids and finally the His-tagged protein was added to the GUVs to form the Co3+ mediated bond. This system was also established using the microfluidic device.
The different preparation procedures of GUVs usually lead to vesicles with a spherical morphology. On the other hand, many cell organelles have a more complex architecture with a non spherical topology. One fascinating example is provided by the endoplasmic reticulum (ER) which is made of a continuous membrane and extends throughout the cell in the form of tubes and sheets. The tubes are connected by three-way junctions and form a tubular network of irregular polygons. The formation and maintenance of these reticular networks requires membrane proteins that hydrolyize guanosine triphosphate (GTP). One of these membrane proteins is atlastin. In this thesis, I reconstituted the atlastin protein in GUV membranes using detergent-assisted reconstitution protocols to insert the proteins directly into lipid bilayers.
This thesis focuses on protein reconstitution by binding His-tagged proteins to anchor lipids and by detergent-assisted insertion of proteins with transmembrane domains. It also provides the design of a microfluidic device that can be used in various experiments, one example is the evaluation of the equilibrium dissociation constant for membrane-protein interactions. The results of this thesis will help other researchers to understand the protocols for preparing GUVs, to reconstitute proteins in GUVs, and to perform experiments using the microfluidic device. This knowledge should be beneficial for the long-term goal of combining the different modules of synthetic biology to make a minimal cell.
An important goal in biotechnology and (bio-) medical research is the isolation of single cells from a heterogeneous cell population. These specialised cells are of great interest for bioproduction, diagnostics, drug development, (cancer) therapy and research. To tackle emerging questions, an ever finer differentiation between target cells and non-target cells is required. This precise differentiation is a challenge for a growing number of available methods.
Since the physiological properties of the cells are closely linked to their morphology, it is beneficial to include their appearance in the sorting decision. For established methods, this represents a non addressable parameter, requiring new methods for the identification and isolation of target cells. Consequently, a variety of new flow-based methods have been developed and presented in recent years utilising 2D imaging data to identify target cells within a sample. As these methods aim for high throughput, the devices developed typically require highly complex fluid handling techniques, making them expensive while offering limited image quality.
In this work, a new continuous flow system for image-based cell sorting was developed that uses dielectrophoresis to precisely handle cells in a microchannel. Dielectrophoretic forces are exerted by inhomogeneous alternating electric fields on polarisable particles (here: cells). In the present system, the electric fields can be switched on and off precisely and quickly by a signal generator. In addition to the resulting simple and effective cell handling, the system is characterised by the outstanding quality of the image data generated and its compatibility with standard microscopes. These aspects result in low complexity, making it both affordable and user-friendly.
With the developed cell sorting system, cells could be sorted reliably and efficiently according to their cytosolic staining as well as morphological properties at different optical magnifications. The achieved purity of the target cell population was up to 95% and about 85% of the sorted cells could be recovered from the system. Good agreement was achieved between the results obtained and theoretical considerations. The achieved throughput of the system was up to 12,000 cells per hour. Cell viability studies indicated a high biocompatibility of the system.
The results presented demonstrate the potential of image-based cell sorting using dielectrophoresis. The outstanding image quality and highly precise yet gentle handling of the cells set the system apart from other technologies. This results in enormous potential for processing valuable and sensitive cell samples.
An electrochemical detection system specifically designed for multi-parameter real-time monitoring of stem cell culturing/differentiation in a microfluidic system is presented. It is composed of a very compact 24-channel electronic board, compatible with arrays of microelectrodes and coupled to a microfluidic cell culture system. A versatile data acquisition software enables performing amperometry, cyclic voltammetry and impedance spectroscopy in each of the 12 independent chambers over a 100 kHz bandwidth with current resolution down to 5 pA for 100 ms measuring time. The design of the platform, its realization and experimental characterization are reported, with emphasis on the analysis of impact of input capacitance (i.e., microelectrode size) and microfluidic pump operation on current noise. Programmable sequences of successive injections of analytes (ferricyanide and dopamine) and rinsing buffer solution as well as the impedimetric continuous tracking for seven days of the proliferation of a colony of PC12 cells are successfully demonstrated.