Protected cultivation in greenhouses or polytunnels offers the potential for sustainable production of high-yield, high-quality vegetables. This is related to the ability to produce more on less land and to use resources responsibly and efficiently. Crop yield has long been considered the most important factor. However, as plant-based diets have been proposed for a sustainable food system, the targeted enrichment of health-promoting plant secondary metabolites should be addressed. These metabolites include carotenoids and flavonoids, which are associated with several health benefits, such as cardiovascular health and cancer protection.
Cover materials generally have an influence on the climatic conditions, which in turn can affect the levels of secondary metabolites in vegetables grown underneath. Plastic materials are cost-effective and their properties can be modified by incorporating additives, making them the first choice. However, these additives can migrate and leach from the material, resulting in reduced service life, increased waste and possible environmental release. Antifogging additives are used in agricultural films to prevent the formation of droplets on the film surface, thereby increasing light transmission and preventing microbiological contamination.
This thesis focuses on LDPE/EVA covers and incorporated antifogging additives for sustainable protected cultivation, following two different approaches. The first addressed the direct effects of leached antifogging additives using simulation studies on lettuce leaves (Lactuca sativa var capitata L). The second determined the effect of antifog polytunnel covers on lettuce quality. Lettuce is usually grown under protective cover and can provide high nutritional value due to its carotenoid and flavonoid content, depending on the cultivar.
To study the influence of simulated leached antifogging additives on lettuce leaves, a GC-MS method was first developed to analyze these additives based on their fatty acid moieties. Three structurally different antifogging additives (reference material) were characterized outside of a polymer matrix for the first time. All of them contained more than the main fatty acid specified by the manufacturer. Furthermore, they were found to adhere to the leaf surface and could not be removed by water or partially by hexane.
The incorporation of these additives into polytunnel covers affects carotenoid levels in lettuce, but not flavonoids, caffeic acid derivatives and chlorophylls. Specifically, carotenoids were higher in lettuce grown under polytunnels without antifog than with antifog. This has been linked to their effect on the light regime and was suggested to be related to carotenoid function in photosynthesis.
In terms of protected cultivation, the use of LDPE/EVA polytunnels affected light and temperature, and both are closely related. The carotenoid and flavonoid contents of lettuce grown under polytunnels was reversed, with higher carotenoid and lower flavonoid levels. At the individual level, the flavonoids detected in lettuce did not differ however, lettuce carotenoids adapted specifically depending on the time of cultivation. Flavonoid reduction was shown to be transcriptionally regulated (CHS) in response to UV light (UVR8). In contrast, carotenoids are thought to be regulated post-transcriptionally, as indicated by the lack of correlation between carotenoid levels and transcripts of the first enzyme in carotenoid biosynthesis (PSY) and a carotenoid degrading enzyme (CCD4), as well as the increased carotenoid metabolic flux. Understanding the regulatory mechanisms and metabolite adaptation strategies could further advance the strategic development and selection of cover materials.
One aspect of achieving a more sustainable chemical industry is the minimization of the usage of solvents and chemicals. Thus, optimization and development of chemical processes for large-scale production is favourably performed in small batches. The critical step in this approach is upscaling the batches from the small reaction systems to the large reactors mandatory for cost efficient production in an industrial environment. Scaling up the bulk volume always goes along with increasing the surface where the reaction medium is in contact with the confining vessel. Since volume scales proportional with the cubic dimension while the surface scales quadratic, their ratio is size-dependent. The influence of reaction vessel walls can change the reaction performance. A number of phenomena occurring at the surface-liquid interface can affect reaction rates and yields, resulting in possible difficulties in predicting and extrapolating from small size production scale to large industrial processes. The application of levitated droplets as a containerless reaction vessels provides a promising possibility to avoid the above-mentioned issues.
In the presented work, an efficient coupling of acoustically levitated droplets to an ion mobility (IM) spectrometer, operating at ambient conditions, was designed for real-time monitoring of chemical reactions. The design of the system comprises noncontact sampling and ionization of the droplet realised by laser desorption/ionization at 2,94 µm. The scope of the work includes fundamental studies covering understanding of laser irradiation of droplets enclosed in an acoustical field. Understanding of this phenomenon is crucial to comprehending the effects of temporal and spatial resolution of the generated ion plume that influence the resolution of the system.
The set-up includes an acoustic trap, laser irradiation and ion manipulation electrostatic lenses operating at high voltage at ambient pressure. The complexity of the design needs to fully be considered for an effective ion transfer at the interface region between the levitated droplet and IM spectrometer. For sampling and ionization, two distinct laser pulse lengths were evaluated, ns and µs. Irradiation via µs laser pulses provides several advantages: i) the droplet volume is not extensively impinged, as in case of ns laser pulses, allowing the sampling of only the small volume of the droplet; ii) the lower fluence results in less pronounced oscillations of the droplet confined in the acoustic field. The droplet will not be dissipated out of the acoustic field leading to loss of the sample; iii) the mild laser irradiation results in better spatial and temporal ion plume confinement, leading to better resolution of the detected ion packets. Finally, this knowledge allows the application of ion optics necessary to induce ion flow between the droplet suspended in the acoustic field and the IM spectrometer. The ion optics, composed of 2 electrostatic lenses placed in the near vicinity of the droplet, allow effective focusing of the ion plume and its redirection directly to the IM spectrometer entrance. This novel coupling has proved to be successful for detection of some simple molecules ionizable at the 2.94 µm wavelength. To further demonstrate the applicability of the system, a proof-of-principle reaction was selected, fulfilling the requirements of the system, and was subjected to comprehensive investigation of its performance. Herein, the reaction between N-Boc cysteine methyl ester and allyl alcohol has been performed in a batch reactor and on-line monitored via 1H NMR to establish reaction propagation. With the additional assessment, it was confirmed that the thiol-ene coupling can be performed within first 20 minutes of the irradiation with a reaction yield above 50%, proving that the reaction can be applied as a study case to assess the possibilities of the developed system.
The aim of this thesis was the elucidation of different ionization methods (resonance-enhanced multiphoton ionization – REMPI, electrospray ionization – ESI, atmospheric pressure chemical ionization – APCI) in ion mobility (IM) spectrometry. In order to gain a better understanding of the ionization processes, several spectroscopic, mass spectrometric and theoretical methods were also used. Another focus was the development of experimental techniques, including a high resolution spectrograph and various combinations of IM and mass spectrometry.
The novel high resolution 2D spectrograph facilitates spectroscopic resolutions in the range of commercial echelle spectrographs. The lowest full width at half maximum of a peak achieved was 25 pm. The 2D spectrograph is based on the wavelength separation of light by the combination of a prism and a grating in one dimension, and an etalon in the second dimension. This instrument was successfully employed for the acquisition of Raman and laser-induced breakdown spectra.
Different spectroscopic methods (light scattering and fluorescence spectroscopy) permitting a spatial as well as spectral resolution, were used to investigate the release of ions in the electrospray. The investigation is based on the 50 nm shift of the fluorescence band of rhodamine 6G ions of during the transfer from the electrospray droplets to the gas phase.
A newly developed ionization chamber operating at reduced pressure (0.5 mbar) was coupled to a time-of-flight mass spectrometer. After REMPI of H2S, an ionization chemistry analogous to H2O was observed with this instrument. Besides H2S+ and its fragments, H3S+ and protonated analyte ions could be observed as a result of proton-transfer reactions.
For the elucidation of the peaks in IM spectra, a combination of IM spectrometer and linear quadrupole ion trap mass spectrometer was developed. The instrument can be equipped with various ionization sources (ESI, REMPI, APCI) and was used for the characterization of the peptide bradykinin and the neuroleptic promazine.
The ionization of explosive compounds in an APCI source based on soft x-radiation was investigated in a newly developed ionization chamber attached to the ion trap mass spectrometer. The major primary and secondary reactions could be characterized and explosive compound ions could be identified and assigned to the peaks in IM spectra. The assignment is based on the comparison of experimentally determined and calculated IM. The methods of calculation currently available exhibit large deviations, especially in the case of anions. Therefore, on the basis of an assessment of available methods, a novel hybrid method was developed and characterized.
Zur Detektion neuer IgE- reaktiver Proteine wurde in dieser Arbeit ein zweidimensionales Proteintrennverfahren verwendet. Resultierende Proteinfraktionen wurden mithilfe von 18 tomatensensibiliesierten Patientenseren im Immunoblot getestet. Detektierte Proteine in der SDS-PAGE wurden mittels LC-MS/MS identifiziert. Dadurch konnten 2 Tomatensamenproteine, die im Immunoblot ein IgE- reaktives Signal zeigten eindeutig mittels Massenspektrometrie identifiziert werden. Diese Proteine sind Legumin und Vicilin. Durch Sequenzabgleich und Proteinstrukturmodellierung im Vergleich zu bereits bekannten Allergenen (Erdnuss und Cashewnuss), konnte eine hohe Homologie gezeigt werden.
Chitooligosaccharides are composed of glycosamin and N-acetylglycisamin residues. Gel permeations chromatography is employed for the separation of oligomers, cation exchange chromatography is used for the separation of homologes and isomers. Trideuterioacetylation of the chitooligosaccharides followed by MALDI-TOF mass spectrometry allowes for the quantitation of mixtures of homologes. vMALDI LTQ multiple-stage MS is employed for quantitative sequencing of complex mixtures of heterochitooligosaccharides. Pure homologes and isomers are applied to biological assays. Chitooligosaccahrides form high-affinity non-covalent complexes with HC gp-39 (human cartilage glycoprotein of 39 kDa). The affinity of the chitooligosaccharides depends on DP, FA and the sequence of glycosamin and N-acetylglycosamin moieties. (+)nanoESI Q TOF MS/MS is used for identification of a high-affinity binding chitooligosaccharide of a non-covalent chitinase B - chitooligosaccharide complex. DADAA is identified as the heterochitoisomer binding with highest affinity and biostability to HC gp-39. Fluorescence based enzyme assays confirm the results.
From its first use in the field of biochemistry, instrumental analysis offered a variety of invaluable tools for the comprehensive description of biological systems. Multi-selective methods that aim to cover as many endogenous compounds as possible in biological samples use different analytical platforms and include methods like gene expression profile and metabolite profile analysis. The enormous amount of data generated in application of profiling methods needs to be evaluated in a manner appropriate to the question under investigation. The new field of system biology rises to the challenge to develop strategies for collecting, processing, interpreting, and archiving this vast amount of data; to make those data available in form of databases, tools, models, and networks to the scientific community. On the background of this development a multi-selective method for the determination of phytohormones was developed and optimised, complementing the profile analyses which are already in use (Chapter I). The general feasibility of a simultaneous analysis of plant metabolites and phytohormones in one sample set-up was tested by studies on the analytical robustness of the metabolite profiling protocol. The recovery of plant metabolites proved to be satisfactory robust against variations in the extraction protocol by using common extraction procedures for phytohormones; a joint extraction of metabolites and hormones from plant tissue seems practicable (Chapter II). Quantification of compounds within the context of profiling methods requires particular scrutiny (Chapter II). In Chapter III, the potential of stable-isotope in vivo labelling as normalisation strategy for profiling data acquired with mass spectrometry is discussed. First promising results were obtained for a reproducible quantification by stable-isotope in vivo labelling, which was applied in metabolomic studies. In-parallel application of metabolite and phytohormone analysis to seedlings of the model plant Arabidopsis thaliana exposed to sulfate limitation was used to investigate the relationship between the endogenous concentration of signal elements and the ‘metabolic phenotype’ of a plant. An automated evaluation strategy was developed to process data of compounds with diverse physiological nature, such as signal elements, genes and metabolites – all which act in vivo in a conditional, time-resolved manner (Chapter IV). Final data analysis focussed on conditionality of signal-metabolome interactions.