Refine
Document Type
- Article (3)
- Doctoral Thesis (1)
Language
- English (4)
Is part of the Bibliography
- yes (4) (remove)
Keywords
Institute
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of H-1 spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and ally] alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibration free approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h(-1) at 25 degrees C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance. (C) 2017 Elsevier Inc. All rights reserved.
In many laser based ionization techniques with a subsequent drift time separation, the laser pulse generating the ions is considered as the start time to. Therefore, an accurate temporal definition of this event is crucial for the resolution of the experiments. In this contribution, the laser induced plume dynamics of liquids evaporating into atmospheric pressure are visualized for two distinctively different laser pulse widths, Delta t = 6 nanoseconds and Delta tau = 280 microseconds. For ns-pulses the expansion of the generated vapour against atmospheric pressure is found to lead to turbulences inside the gas phase. This results in spatial and temporal broadening of the nascent clouds. A more equilibrated expansion, without artificial smearing of the temporal resolution can, in contrast, be observed to follow mu s-pulse excitation. This leads to the counterintuitive finding that longer laser pulses results in an increased temporal vapour formation definition. To examine if this fume expansion also eventually results in a better definition of ion formation, the nascent vapour plumes were expanded into a linear drift tube ion mobility spectrometer (IMS). This time resolved detection of ion formation corroborates the temporal broadening caused by collisional impeding of the supersonic expansion at atmospheric pressure and the overall better defined ion formation by evaporation with long laser pulses. A direct comparison of the observed results strongly suggests the coexistence of two individual ion formation mechanisms that can be specifically addressed by the use of appropriate laser sources.
Acoustically levitated droplets have been suggested as compartmentalized, yet wall-less microreactors for high-throughput reaction optimization purposes. The absence of walls is envisioned to simplify up-scaling of the optimized reaction conditions found in the microliter volumes. A consequent pursuance of high-throughput chemistry calls for a fast, robust and sensitive analysis suited for online interrogation. For reaction optimization, targeted analysis with relatively low sensitivity suffices, while a fast, robust and automated sampling is paramount. To follow this approach, in this contribution, a direct coupling of levitated droplets to a homebuilt ion mobility spectrometer (IMS) is presented. The sampling, transfer to the gas phase, as well as the ionization are all performed by a single exposure of the sampling volume to the resonant output of a mid-IR laser. Once formed, the nascent spatially and temporally evolving analyte ion cloud needs to be guided out of the acoustically confined trap into the inlet of the ion mobility spectrometer. Since the IMS is operated at ambient pressure, no fluid dynamic along a pressure gradient can be employed. Instead, the transfer is achieved by the electrostatic potential gradient inside a dual ring electrode ion optics, guiding the analyte ion cloud into the first stage of the IMS linear drift tube accelerator. The design of the appropriate atmospheric pressure ion optics is based on the original vacuum ion optics design of Wiley and McLaren. The obtained experimental results nicely coincide with ion trajectory calculations based on a collisional model.
One aspect of achieving a more sustainable chemical industry is the minimization of the usage of solvents and chemicals. Thus, optimization and development of chemical processes for large-scale production is favourably performed in small batches. The critical step in this approach is upscaling the batches from the small reaction systems to the large reactors mandatory for cost efficient production in an industrial environment. Scaling up the bulk volume always goes along with increasing the surface where the reaction medium is in contact with the confining vessel. Since volume scales proportional with the cubic dimension while the surface scales quadratic, their ratio is size-dependent. The influence of reaction vessel walls can change the reaction performance. A number of phenomena occurring at the surface-liquid interface can affect reaction rates and yields, resulting in possible difficulties in predicting and extrapolating from small size production scale to large industrial processes. The application of levitated droplets as a containerless reaction vessels provides a promising possibility to avoid the above-mentioned issues.
In the presented work, an efficient coupling of acoustically levitated droplets to an ion mobility (IM) spectrometer, operating at ambient conditions, was designed for real-time monitoring of chemical reactions. The design of the system comprises noncontact sampling and ionization of the droplet realised by laser desorption/ionization at 2,94 µm. The scope of the work includes fundamental studies covering understanding of laser irradiation of droplets enclosed in an acoustical field. Understanding of this phenomenon is crucial to comprehending the effects of temporal and spatial resolution of the generated ion plume that influence the resolution of the system.
The set-up includes an acoustic trap, laser irradiation and ion manipulation electrostatic lenses operating at high voltage at ambient pressure. The complexity of the design needs to fully be considered for an effective ion transfer at the interface region between the levitated droplet and IM spectrometer. For sampling and ionization, two distinct laser pulse lengths were evaluated, ns and µs. Irradiation via µs laser pulses provides several advantages: i) the droplet volume is not extensively impinged, as in case of ns laser pulses, allowing the sampling of only the small volume of the droplet; ii) the lower fluence results in less pronounced oscillations of the droplet confined in the acoustic field. The droplet will not be dissipated out of the acoustic field leading to loss of the sample; iii) the mild laser irradiation results in better spatial and temporal ion plume confinement, leading to better resolution of the detected ion packets. Finally, this knowledge allows the application of ion optics necessary to induce ion flow between the droplet suspended in the acoustic field and the IM spectrometer. The ion optics, composed of 2 electrostatic lenses placed in the near vicinity of the droplet, allow effective focusing of the ion plume and its redirection directly to the IM spectrometer entrance. This novel coupling has proved to be successful for detection of some simple molecules ionizable at the 2.94 µm wavelength. To further demonstrate the applicability of the system, a proof-of-principle reaction was selected, fulfilling the requirements of the system, and was subjected to comprehensive investigation of its performance. Herein, the reaction between N-Boc cysteine methyl ester and allyl alcohol has been performed in a batch reactor and on-line monitored via 1H NMR to establish reaction propagation. With the additional assessment, it was confirmed that the thiol-ene coupling can be performed within first 20 minutes of the irradiation with a reaction yield above 50%, proving that the reaction can be applied as a study case to assess the possibilities of the developed system.