Refine
Year of publication
Document Type
- Article (246)
- Postprint (7)
- Review (7)
- Part of a Book (2)
- Other (2)
- Monograph/Edited Volume (1)
- Doctoral Thesis (1)
Keywords
Because of its high reaction rate and specificity, the enzyme superoxide dismutase (SOD) offers great potential for the sensitive quantification of superoxide radicals in electrochemical biosensors. In this work, monomeric mutants of human Cu,Zn-SOD were engineered to contain one or two additional cysteine residues, which could be used to bind the protein to gold surfaces, thus making the use of promotor molecules unnecessary. Six mutants were successfully designed, expressed, and purified. All mutants bound directly to unmodified gold surfaces via the sulfur of the cysteine residues and showed a quasireversible, direct electron transfer to the electrode. Thermodynamic and kinetic parameters of the electron transfer were characterized and showed only slight variations between the individual mutants. For one of the mutants, the interaction with the superoxide radical was studied in more detail. For both partial reactions of the dismutation, an interaction between protein and radical could be shown. In an amperometric biosensorial approach, the SOD-mutant electrode was successfully applied for the detection of superoxide radicals. In the oxidation region, the electrode surpassed the sensitivity of the commonly used cytochrome c electrodes by similar to 1 order of magnitude while not being limited by interferences, but the electrode did not fully reach the sensitivity of dimeric Cu,Zn-SOD immobilized on MPA-modified gold
An amperometric biosensor for the determination of glycated hemoglobin in human whole blood is proposed. The principle is based on the electrochemical measurement of ferroceneboronic acid (FcBA) that has been specifically bound to the glycated N-terminus. Hemoglobin is immobilized on a zirconium dioxide nanoparticle modified pyrolytic graphite electrode (PGE) in the presence of didodecyldimethylammonium bromide (DDAB). The incubation of this sensor in FcBA solution leads to the formation of an FcBA-modified surface due to the affinity interaction between boronate and the glycated sites of the hemoglobin. The binding of FcBA results in well-defined redox peaks with an E-0' of 0.299 V versus Ag/AgCl (1 M KCl). The square wave voltammetric response of the bound FcBA reflects the amount of glycated hemoglobin at the surface. This signal increases linearily with the degree of glycated hemoglobin from 6.8 to 14.0% of total immobilized hemoglobin. The scheme was applied to the determination of the fraction of glycated hemoglobin in whole blood samples.