A new approach to achieve sub-pixel spatial resolution in a pnCCD detector with 75 x 75 mu m(2) pixel size is proposed for X-ray applications in single photon counting mode. The approach considers the energy dependence of the charge cloud created by a single photon and its split probabilities between neighboring pixels of the detector based on a rectangular model for the charge cloud density. For cases where the charge of this cloud becomes distributed over three or four pixels the center position of photon impact can be reconstructed with a precision better than 2 mu m. The predicted charge cloud sizes are tested at selected X-ray fluorescence lines emitting energies between 6.4 keV and 17.4 keV and forming charge clouds with size (rms) varying between 8 mu m and 10 mu m respectively. The 2 mu m enhanced spatial resolution of the pnCCD is verified by means of an x-ray transmission experiment throughout an optical grating.
In this work we study the response of a pnCCD by means of X-ray spectroscopy in the energy range between 6 key and 20 key and by Laue diffraction techniques. The analyses include measurements of characteristic detector parameters like energy resolution, count rate capability and effects of different gain settings. The limit of a single photon counting operation in white beam X-ray diffraction experiments is discussed with regard to the occurrence of pile-up events, for which the energy information about individual photons is lost. In case of monochromatic illumination the pnCCD can be used as a fast conventional CCD with a charge handling capacity (CHC) of about 300,000 electrons per pixel. If the CHC is exceeded, any surplus charge will spill to neighboring pixels perpendicular to the transfer direction due to electrostatic repulsion. The possibilities of increasing the number of storable electrons are investigated for different voltage settings by exposing a single pixel with X-rays generated by a microfocus X-ray source. The pixel binning mode is tested as an alternative approach that enables a pnCCD operation with significantly shorter readout times.
A crystal of hen egg-white lysozyme was analyzed by means of energy-dispersive X-ray Laue diffraction with white synchrotron radiation at 2.7 angstrom resolution using a pnCCD detector. From Laue spots measured in a single exposure of the arbitrarily oriented crystal, the lattice constants of the tetragonal unit cell could be extracted with an accuracy of about 2.5%. Scanning across the sample surface, Laue images with split reflections were recorded at various positions. The corresponding diffraction patterns were generated by two crystalline domains with a tilt of about 1 degrees relative to each other. The obtained results demonstrate the potential of the pnCCD for fast X-ray screening of crystals of macromolecules or proteins prior to conventional X-ray structure analysis. The described experiment can be automatized to quantitatively characterize imperfect single crystals or polycrystals.