Refine
Year of publication
Document Type
Is part of the Bibliography
- yes (220)
Keywords
- biomaterials (9)
- Biomaterial (6)
- Polymer (6)
- polymer (6)
- shape-memory effect (6)
- Hydrogel (5)
- biomaterial (5)
- electrospinning (5)
- stimuli-sensitive polymers (5)
- Langmuir monolayer (4)
- mesenchymal stem cells (4)
- morphology (4)
- multiblock copolymer (4)
- shape memory (4)
- Biomaterials (3)
- Degradation (3)
- Polymers (3)
- artificial muscles (3)
- cell adhesion (3)
- endothelial cells (3)
- hemocompatibility (3)
- microparticles (3)
- microstructure (3)
- poly(ether imide) (3)
- shape-memory polymers (3)
- soft robotics (3)
- Actuation (2)
- Biomimetic (2)
- Biopolymer (2)
- Degradable (2)
- Depsipeptide (2)
- Enzymatic degradation (2)
- Gelatin (2)
- HDAC1 (2)
- Hyaluronic acid (2)
- Hydrolytic degradation (2)
- Membrane (2)
- Mesenchymal stem cells (2)
- Molecular modeling (2)
- Nanostructure (2)
- Oligo(epsilon-caprolactone) (2)
- Phase morphology (2)
- Poly(epsilon-caprolactone) (2)
- RUNX2 (2)
- Rheology (2)
- Shape memory (2)
- Shape-memory effect (2)
- Shape-memory polymer (2)
- Temperature-memory effect (2)
- Thin film (2)
- actuation (2)
- atomic force microscopy (2)
- biodegradable polymers (2)
- calcium influx (2)
- cells (2)
- crystallization (2)
- crystallization behavior (2)
- degradation (2)
- efficient (2)
- ellipsometry (2)
- fiber actuators (2)
- gelatin (2)
- gene delivery (2)
- hydrogel (2)
- hydrogels (2)
- immunogenicity (2)
- lipoplexes (2)
- mechanical (2)
- mediated delivery (2)
- migration (2)
- multifunctional polymers (2)
- oligodepsipeptides (2)
- pathways (2)
- phase morphology (2)
- platelets (2)
- polarization (2)
- poly(epsilon-caprolactone) (2)
- poly(ethylene glycol) (2)
- polyester (2)
- polyesterurethanes (2)
- polyglycerol (2)
- properties (2)
- protein adsorption (2)
- resistive heating (2)
- reversible shape-memory actuator (2)
- ring-opening polymerization (2)
- shape‐memory polymer actuators (2)
- sirna transfection (2)
- soft actuators (2)
- spectroscopic ellipsometry (2)
- stem cell adhesion (2)
- surface functionalization (2)
- temperature-memory effect (2)
- therapeutics (2)
- thrombogenicity (2)
- (NMR) (1)
- 2D materials (1)
- 3D-printing (1)
- 4D-actuation (1)
- Actuators (1)
- Additive manufacturing (1)
- Adipocyte (1)
- Adsorption of uremic toxins (1)
- Aerophobicity (1)
- Ageing (1)
- Air bubble repellence (1)
- Angle-dependent X-ray induced photoelectron spectroscopy (1)
- Antiviral (1)
- Biocompatibility testing (1)
- Biocompatible polymers (1)
- Biomolecules coupling (1)
- Biopolymer material (1)
- Biopolymers (1)
- Brewster angle microscopy (1)
- COVID-19 (1)
- Cartilage repair (1)
- Chondrocytes (1)
- Chronic kidney disease (1)
- Chronic kidney disease (CKD) (1)
- Cinnamylidene acetic acid (1)
- Click chemistry (1)
- Collagen-binding peptide (1)
- Composite (1)
- Crosslinking (1)
- Deformation (1)
- Degradable polymer (1)
- Docking study (1)
- Drug delivery systems (1)
- Drug loading (1)
- Electrospinning (1)
- Endothelial cells (1)
- Endothelialization (1)
- Energy (1)
- Energy storage (1)
- Enzymatic polymer degradation (1)
- FAK-MAPK (1)
- Fastener (1)
- Fiber (1)
- Function by design (1)
- Functionalization (1)
- Gripper (1)
- High-throughput (1)
- Hydrogels (1)
- Hydrolytic stability (1)
- Hydroxyapatite (1)
- Hypoxia (1)
- In situ (1)
- Inflammation (1)
- Ink (1)
- Ki67 (1)
- Langmuir layers (1)
- Langmuir monolayer degradation technique (1)
- Langmuir monolayers (1)
- Langmuir technique (1)
- Langmuir thin-films (1)
- Langmuir-Schaefer method (1)
- Langmuir-Schafer films (1)
- Macrophage (1)
- Magnetic composites (1)
- Magnetite nanoparticles (1)
- Mass spectrometry (1)
- Matrix metalloproteinase (1)
- Mechanical properties (1)
- Methacrylate (1)
- Microindentation (1)
- Microstructure (1)
- Modeling (1)
- Modelling (1)
- Molecular (1)
- Molecular dynamics simulation (1)
- Molecular interaction design (1)
- Molecular orientation (1)
- Molecular weight (1)
- Monolayer (1)
- Morpholindione (1)
- Multiblock copolymer (1)
- Multiblock copolymers (1)
- Multifunctional polyester networks (1)
- Multifunctionality (1)
- NICE-2014 (1)
- Nanofiber (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Near infrared light triggered shape-recovery (1)
- Negative control (1)
- Nuclear magnetic resonance (1)
- OEG-OPG-OEG triblock copolymer (1)
- Oligo(ethylene glycol) (1)
- Oligo(ethylene glycol) derivatization (1)
- Oligo(omega-pentadecalactone) (1)
- Oligodepsipeptide (1)
- Oligoglycerols (1)
- On-demand release (1)
- PDLLGA (1)
- PHA-depolymerases (1)
- Packaging (1)
- Particle shape (1)
- Particle size (1)
- Phagocytosis (1)
- Photoresponsive polymers (1)
- Physical Network (1)
- Platelet (1)
- Poly(carbonate-urea-urethane)s (1)
- Poly(epsilon-caprolactone) networks (1)
- Poly(ether imide) (1)
- Poly(n-butyl acrylate) (1)
- Poly[acrylonitrile-co-(N-vinyl pyrrolidone)] (1)
- Polyesterurethane (1)
- Polyether ether ketone (1)
- Polylactide stereocomplex (1)
- Polymer architecture (1)
- Polymer functionalization (1)
- Polymer micronetwork colloids (1)
- Polymer network properties (1)
- Polymer networks (1)
- Polymeric substrate (1)
- Porous poly(ether imide) microparticulate absorbers (1)
- Protein (1)
- Proteins (1)
- RGD peptides (1)
- RGD-peptide (1)
- Raman spectroscopy (1)
- Random copolymer (1)
- Rheological characterization (1)
- Ring-opening polymerization (1)
- Robotic synthesis (1)
- Robotics (1)
- SAXS (1)
- Scaffold contraction (1)
- Scaffold degradation (1)
- Scaffold stiffness (1)
- Scanning probe microscopy (SPM) (1)
- Sequence structure (1)
- Shape-memory (1)
- Simulation (1)
- Skin absorption (1)
- Sn(IV) alkoxide (1)
- Submicron particles (1)
- Sulfated polymer (1)
- Surface functionalization (1)
- Surface reaction (1)
- Surfactants (1)
- Switchable wettability (1)
- TCP (1)
- THP-1 cells (1)
- Telechel (1)
- Thermo-responsive polymer (1)
- Thermomechanical history (1)
- Tin octanoate (1)
- UV crosslinking (1)
- Uremic toxins (1)
- VEGF (1)
- WAXS (1)
- Water (1)
- X-ray scattering (1)
- actin cytoskeleton (1)
- active polymer (1)
- active scaffold (1)
- adipogenic differentiation (1)
- adipose tissue regeneration (1)
- adsorber materials (1)
- aerophobicity (1)
- air - water interface (1)
- air bubble repellence (1)
- amide ligand (1)
- amorphous polymers (1)
- assembly capabilities (1)
- atomic force microscopy (AFM) (1)
- basement membrane (1)
- beta-galactosidase (1)
- biocompatibility (1)
- biofunctionalization (1)
- bioinspired materials (1)
- bioinstructive implants (1)
- bioinstructive materials (1)
- biological applications of polymers (1)
- biological membrane (1)
- biomaterial characterization (1)
- biomaterial-tissue interface (1)
- biomedical (1)
- biomimetic (chemical reaction) (1)
- biopolymer (1)
- bioprinting (1)
- blend (1)
- block copolymers (1)
- block-copolymer (1)
- blood tests (1)
- body temperature (1)
- brewster angle microscopy (1)
- broad melting temperature range (1)
- capsule formation (1)
- cardiac regeneration (1)
- cardiovascular disease (1)
- cardiovascular implant (1)
- catalyst (1)
- cavitation-based mechanical force (1)
- cell culture (1)
- cell culture device (1)
- cell cycle inhibitors (1)
- cell encapsulation (1)
- cell selectivity (1)
- cell-material interaction (1)
- chain-extended (1)
- chemical synthesis (1)
- chronic kidney disease (CKD) (1)
- co-expression (1)
- cold (1)
- collagen (1)
- collagen-IV (1)
- composite (1)
- controlled release (1)
- controlled-release (1)
- coordination bonds (1)
- copolymer networks (1)
- copper-catalyzed alkyne-azide cycloaddition (1)
- critical micellation temperature (1)
- cross-linking (1)
- crosslinking (1)
- crystal structures (1)
- crystalline (1)
- crystallinity (1)
- cyclic olefin copolymer (1)
- cyclic thermomechanical testing (1)
- cyclodextrin (1)
- cytokine release (1)
- cytokines/chemokines (1)
- cytotoxicity (1)
- dedifferentiation (1)
- degradable (1)
- degradable polyester (1)
- degradable polymer (1)
- degradable polymers (1)
- dendritic cells (1)
- differentiation (1)
- diffusion (1)
- drug eluting stent (1)
- elastomers (1)
- electron microscopy (1)
- electrospun scaffold (1)
- ellipsometric mapping (1)
- endothelial basement membrane (1)
- engineering (1)
- enzymatic degradation (1)
- enzymatic-degradation (1)
- enzyme (1)
- ethylene oxide (1)
- excimer UV light (1)
- extracellular matrix modifying enzymes (1)
- fiber meshes (1)
- fibers (1)
- fibrinogen (1)
- fibroblast (1)
- fibronectin (1)
- films (1)
- fluorescence stimuli‐ responsivity (1)
- foam (1)
- focal adhesion (1)
- foreign body giant cells (1)
- form stability (1)
- function (1)
- function by structure; (1)
- functional (1)
- functionalization of polymers (1)
- gelatin based scaffold (1)
- gelatin-based hydrogels (1)
- gels (1)
- glass (1)
- hemodialysis (1)
- human monocytic (THP-1) cells (1)
- hydrophobic uremic toxins (1)
- implants (1)
- in vitro (1)
- in vitro synthesized mRNA (1)
- in vitro thrombogenicity testing (1)
- in vivo study (1)
- inclusion complex (1)
- induced pluripotent stem cells (1)
- integrated co-transfection (1)
- inverse (1)
- iron (1)
- langmuir monolayer (1)
- langmuir monolayers (1)
- libraries (1)
- library (1)
- life cycle assessment (1)
- lipase release (1)
- lipases (1)
- lipid (1)
- liquid-crystalline polymers (1)
- macrophage subsets (1)
- magnetic (1)
- magnetic nanoparticles (1)
- magnetosensitivity (1)
- materials science (1)
- matrix elasticity (1)
- mechanical property (1)
- mechanotransduction (1)
- mercury intrusion porosimetry (1)
- microgels (1)
- microporous (1)
- microscale (1)
- modulation of in vivo regeneration (1)
- modulus (1)
- molecular dynamics simulations (1)
- molecular modeling (1)
- multiblock copolymers (1)
- multifunctional biomaterials (1)
- multiple functions (1)
- nanocarriers (1)
- nanocomposites (1)
- nanoparticle characterization (1)
- nanoscale (1)
- nanostructure (1)
- network structure (1)
- networks (1)
- on demand particle release (1)
- optical imaging (1)
- orientational memory (1)
- osteogenic differentiation (1)
- oxygen plasma (1)
- p16 (1)
- p21 (1)
- parallel co-transfection (1)
- particulate (1)
- peptides (1)
- photoinduced radical polymerization (1)
- platelet activation (1)
- platelet adhesion (1)
- platelet aging (1)
- platelet function (1)
- platelet rich plasma (1)
- platelet storage (1)
- platelet-rich plasma (1)
- poly(e-caprolactone) (1)
- poly(epsilon-caprolactone) methacrylate (1)
- poly(ester amide)s (1)
- poly(ether imide) microparticles (1)
- poly(n-butyl acrylate) (1)
- poly(tetrafluoroethylene) (1)
- poly[(rac-lactide)-co-glycolide] (1)
- polyamines (1)
- polycaprolactone (1)
- polydepsipeptide (1)
- polyesters (1)
- polyesterurethane (1)
- polyhydroxyalkanoates (PHA) (1)
- polyimides (1)
- polymer actuators (1)
- polymer degradation (1)
- polymer foams (1)
- polymer surface (1)
- polymer-based biomaterials (1)
- polymers (1)
- polysiloxanes (1)
- population doubling time (1)
- pore-size distribution (1)
- porosity (1)
- porous microparticles (1)
- precondition (1)
- predictive characterization tools (1)
- processing (1)
- protein (1)
- protein Langmuir layers (1)
- protein-protein interactions (1)
- reactive oxygen species (ROS) (1)
- reference (1)
- renewable (1)
- reshaping abilities (1)
- responsive (1)
- reversible bidirectional shape-memory polymer (1)
- reversible shape-memory effect (1)
- rheology (1)
- rhodium(I)– phosphine (1)
- rhodium-phosphine coordination bonds (1)
- ring opening polymerization (1)
- root mean square roughness (1)
- scaffold (1)
- self-healing (1)
- semi-IPN hydrogels (1)
- semi-crystalline (1)
- senescence-associated (1)
- sequence structures (1)
- shape (1)
- shape change (1)
- shape shifting materials (1)
- shape-memory (1)
- shape-memory hydrogel (1)
- shape-memory polymer (1)
- shape-memory polymer actuators (1)
- shape-memory properties (1)
- side reaction (1)
- side-chains functionalization (1)
- silicone (1)
- soft matter micro- and nanowires (1)
- solvent resistance (1)
- stent coatings (1)
- stereocomplexes (1)
- sterilization (1)
- stimuli-sensitive materials (1)
- successive (1)
- sulfation (1)
- supramolecular polymer network (1)
- surface chemistry (1)
- surface coating (1)
- surface properties (1)
- surfaces (1)
- sustainability (1)
- switch (1)
- switchable wettability (1)
- telechelics (1)
- temperature (1)
- temperature-memory polymers (1)
- thermal properties (1)
- thermal treatments (1)
- thermo-responsive polymer (1)
- thermo-sensitivity (1)
- thermomechanical properties (1)
- thermoplastic elastomer (1)
- thermoplastics (1)
- thermoresponsive polymers (1)
- thermosensitive (1)
- thrombocyte adhesion (1)
- tin(II) 2-ethylhexanoate (1)
- tissue (1)
- transfection (1)
- transfection methods (1)
- triple-shape effect (1)
- two dimensional network (1)
- ultrasound (1)
- uremia (1)
- vascular graft (1)
- vascular grafts (1)
- vascularization (1)
- viability (1)
- whole blood (1)
- wide angle x‐ ray scattering (1)
Quadruple-shape hydrogels
(2019)
The capability of directed movements by two subsequent shape changes could be implemented in shape-memory hydrogels by incorporation of two types of crystallizable side chains While in non-swollen polymer networks even more directed movements could be realized, the creation of multi-shape hydrogels is still a challenge. We hypothesize that a quadruple-shape effect in hydrogels can be realized, when a swelling capacity almost independent of temperature is generated, whereby directed movements could be enabled, which are not related to swelling. In this case, entropy elastic recovery could be realized by hydrophilic segments and the fixation of different macroscopic shapes by means of three semi-crystalline side chains generating temporary crosslinks. Monomethacrylated semi-crystalline oligomers were connected as side chains in a hydrophilic polymer network via radical copolymerization. Computer assisted modelling was utilized to design a demonstrator capable of complex shape shifts by creating a casting mold via 3D printing from polyvinyl alcohol. The demonstrator was obtained after copolymerization of polymer network forming components within the mold, which was subsequently dissolved in water. A thermally-induced quadruple-shape effect was realized after equilibrium swelling of the polymer network in water. Three directed movements were successfully obtained when the temperature was continuously increased from 5 degrees C to 90 degrees C with a recovery ratio of the original shape above 90%. Hence, a thermally-induced quadruple-shape effect as new record for hydrogels was realized. Here, the temperature range for the multi-shape effect was limited by water as swelling media (0 degrees C-100 degrees C), simultaneously distinctly separated thermal transitions were required, and the overall elasticity indispensable for successive deformations was reduced as result of partially chain segment orientation induced by swelling in water. Conclusively the challenges for penta- or hexa-shape gels are the design of systems enabling higher elastic deformability and covering a larger temperature range by switching to a different solvent.
Shape-memory polymer actuators often contain crystallizable polyester segments. Here, the influence of accelerated hydrolytic degradation on the actuation performance in copolymer networks based on oligo(epsilon-caprolactone) dimethacrylate (OCL) and n-butyl acrylate is studied The semi-crystalline OCL was utilized as crosslinker with molecular weights of 2.3 and 15.2 kg.mol(-1) (ratio: 1:1 wt%) and n-butyl acrylate (25 wt% relative to OCL content) acted as softening agent creating the polymer main chain segments within the network architecture. The copolymer networks were programmed by 50% elongation and were degraded by means of alkaline hydrolysis utilizing sodium hydroxide solution (pH = 13). Experiments were performed in the range of the broad melting range of the actuators at 40 degrees C. The degradation of test specimen was monitored by the sample mass, which was reduced by 25 wt% within 105 d .45 degradation products, fragments of OCL with molecular masses ranging from 400 to 50.000 g.mol(-1) could be detected by NMR spectroscopy and GPC measurements. The cleavage of ester groups included in OCL segments resulted in a decrease of the melting temperature (T-m) related to the actuator domains (amorphous at the temperature of degradation) and simultaneously, the T-m associated to the skeleton domain was increased (semi-crystalline at the temperature of degradation). The alkaline hydrolysis decreased the polymer chain orientation of OCL domains until a random alignment of crystalline domains was obtained. This result was confirmed by cyclic thermomechanical actuation tests. The performance of directed movements decreased almost linearly as function of degradation time resulting in the loss of functionality when the orientation of polymer chains disappeared. Here, actuators were able to provide reversible movements until 91 d when the accelerated bulk degradation procedure using alkaline hydrolysis (pH = 13) was applied. Accordingly, a lifetime of more than one year can be guaranteed under physiological conditions (pH = 7.4) when, e.g., artificial muscles for biomimetic robots as potential application for these kind of shape-memory polymer actuators will be addressed.
Polyester-based shape-memory polymer actuators are multifunctional materials providing reversible macroscopic shape shifts as well as hydrolytic degradability. Here, the function-function interdependencies (between shape shifts and degradation behaviour) will determine actuation performance and its life time. In this work, glycolide units were incorporated in poly(epsilon-caprolactone) based actuator materials in order to achieve an accelerated hydrolytic degradation and to explore the function-function relationship. Three different oligo[(epsilon-caprolactone)-co-glycolide] copolymers (OCGs) with similar molecular weights (10.5 +/- 0.5 kg center dot mol(-1)) including a glycolide content of 8, 16, and 26 mol% (ratio 1:1:1 wt%) terminated with methacrylated moieties were crosslinked. The obtained actuators provided a broad melting transition in the range from 27 to 44 degrees C. The hydrolytic degradation of programmed OCG actuators (200% of elongation) resulted in a reduction of sample mass to 51 wt% within 21 days at pH = 7.4 and 40 degrees C. Degradation results in a decrease of T-m associated to the actuating units and increasing T-m associated to the skeleton forming units. The actuation capability decreased almost linear as function of time. After 11 days of hydrolytic degradation the shape-memory functionality was lost. Accordingly, a fast degradation behaviour as required, e.g., for actuator materials intended as implant material can be realized.
Enzymes can support the synthesis or degradation of biomacromolecules in natural processes. Here, we demonstrate that enzymes can induce a macroscopic-directed movement of microstructured hydrogels following a mechanism that we call a "Jack-in-the-box" effect. The material's design is based on the formation of internal stresses induced by a deformation load on an architectured microscale, which are kinetically frozen by the generation of polyester locking domains, similar to a Jack-in-thebox toy (i.e., a compressed spring stabilized by a closed box lid). To induce the controlled macroscopic movement, the locking domains are equipped with enzyme-specific cleavable bonds (i.e., a box with a lock and key system). As a result of enzymatic reaction, a transformed shape is achieved by the release of internal stresses. There is an increase in entropy in combination with a swelling-supported stretching of polymer chains within the microarchitectured hydrogel (i.e., the encased clown pops-up with a pre-stressed movement when the box is unlocked). This utilization of an enzyme as a physiological stimulus may offer new approaches to create interactive and enzyme-specific materials for different applications such as an optical indicator of the enzyme's presence or actuators and sensors in biotechnology and in fermentation processes.
The chemical nature, the number length of integrated building blocks, as well as their sequence structure impact the phase morphology of multiblock copolymers (MBC) consisting of two non-miscible block types. We hypothesized that a strictly alternating sequence should favour phase segregation and in this way the elastic properties. A library of well-defined MBCs composed of two different hydrophobic, semi-crystalline blocks providing domains with well-separated melting temperatures (T(m)s) were synthesized from the same type of precursor building blocks as strictly alternating (MBCsalt) or random (MBCsran) MBCs and compared. Three different series of MBCsalt or MBCsran were synthesized by high-throughput synthesis by coupling oligo(e-caprolactone) (OCL) of different molecular weights (2, 4, and 8 kDa) with oligotetrahydrofuran (OTHF, 2.9 kDa) via Steglich esterification in which the molar ratio of the reaction partners was slightly adjusted. Maximum of weight average molecular weight (M-w) were 65,000 g center dot mol(-1), 165,000 g center dot mol(-1), and 168,000 g center dot mol(-1) for MBCsalt and 80,500 g center dot mol(-1), 100,000 g center dot mol(-1), and 147,600 g center dot mol(-1) for MBCsran. When Mw increased, a decrease of both Tms associated to the melting of the OCL and OTHF domains was observed for all MBCs. T-m (OTHF) of MBCsran was always higher than Tm (OTHF) of MBCsalt, which was attributed to a better phase segregation. In addition, the elongation at break of MBCsalt was almost half as high when compared to MBCsran. In this way this study elucidates role of the block length and sequence structure in MBCs and enables a quantitative discussion of the structure-function relationship when two semi-crystalline block segments are utilized for the design of block copolymers.
The chemical nature, the number length of integrated building blocks, as well as their sequence structure impact the phase morphology of multiblock copolymers (MBC) consisting of two non-miscible block types. It is hypothesized that a strictly alternating sequence should impact phase segregation. A library of well-defined MBC obtained by coupling oligo(epsilon-caprolactone) (OCL) of different molecular weights (2, 4, and 8 kDa) with oligotetrahydrofuran (OTHF, 2.9 kDa) via Steglich esterification results in strictly alternating (MBCalt) or random (MBCran) MBC. The three different series has a weight average molecular weight (M-w) of 65 000, 165 000, and 168 000 g mol(-1) for MBCalt and 80 500, 100 000, and 147 600 g mol(-1) for MBCran. When the chain length of OCL building blocks is increased, the tendency for phase segregation is facilitated, which is attributed to the decrease in chain mobility within the MBC. Furthermore, it is found that the phase segregation disturbs the crystallization by causing heterogeneities in the semi-crystalline alignment, which is attributed to an increase of the disorder of the OCL semi-crystalline alignment.
Porous three-dimensional (3D) scaffolds are promising treatment options in regenerative medicine. Supercritical and dense-phase fluid technologies provide an attractive alternative to solvent-based scaffold fabrication methods. In this work, we report on the fabrication of poly-etheresterurethane (PPDO-PCL) based porous scaffolds with tailorable pore size, porosity, and pore interconnectivity by using supercritical CO2(scCO(2)) fluid-foaming. The influence of the processing parameters such as soaking time, soaking temperature and depressurization on porosity, pore size, and interconnectivity of the foams were investigated. The average pore diameter could be varied between 100-800 mu m along with a porosity in the range from (19 +/- 3 to 61 +/- 6)% and interconnectivity of up to 82%. To demonstrate their applicability as scaffold materials, selected foams were sterilized via ethylene oxide sterilization. They showed negligible cytotoxicity in tests according to DIN EN ISO 10993-5 and 10993-12 using L929 cells. The study demonstrated that the pore size, porosity and the interconnectivity of this multi-phase semicrystalline polymer could be tailored by careful control of the processing parameters during the scCO(2)foaming process. In this way, PPDO-PCL scaffolds with high porosity and interconnectivity are potential candidate materials for regenerative treatment options.
Boronic ester bonds can be reversibly formed between phenylboronic acid (PBA) and triol moieties. Here, we aim at a glucose-induced shape-memory effect by implementing such bonds as temporary netpoints, which are cleavable by glucose and by minimizing the volume change upon stimulation by a porous cryogel structure. The polymer system consisted of a semi-interpenetrating network (semi-IPN) architecture, in which the triol moieties were part of the permanent network and the PBA moieties were located in the linear polymer diffused into the semi-IPN. In an alkaline medium (pH = 10), the swelling ratio was approximately 35, independent of C-glu varied between 0 and 300 mg/dL. In bending experiments, shape fixity R-f approximate to 80% and shape recovery R-r approximate to 100% from five programming/recovery cycles could be determined. R-r was a function of C-glu in the range from 0 to 300 mg/dL, which accords with the fluctuation range of C-glu in human blood. In this way, the shape-memory hydrogels could play a role in future diabetes treatment options.
Silicones are widely used as biomaterials for medical devices such as extracorporeal equipments. However, there is often conflicting evidence about their supposed cell-and histocompatibility. Macrophages could mediate silicone-induced adverse responses such as foreign body reaction and fibrous encapsulation. The polarization behaviour of macrophages could determine the clinical outcome after implantation of biomaterials. Induction of classically activated macrophages (CAM) may induce and support uncontrolled inflammatory responses and undesired material degradation. In contrast, polarization into alternatively activated macrophages (AAM) is assumed to support healing processes and implant integration.
This study compared the interaction of non-polarized macrophages (M0), CAM, and AAM with commercially available tissue culture polystyrene (TCP) and a medical grade silicone-based biomaterial, regarding the secretion of inflammatory mediators such as cytokines and chemokines. Firstly, by using the Limulus amoebocyte lysate (LAL) test the silicone films were shown to be free of soluble endotoxins, which is the prerequisite to investigate their interaction with primary immune cells. Primary human monocyte-derived macrophages (M0) were polarized into CAM and AAM by addition of suitable differentiation factors. These macrophage subsets were incubated on the materials for 24 hours and their viability and cytokine secretion was assessed. In comparison to TCP, cell adhesion was lower on silicone after 24 hours for all three macrophage subsets. However, compared to TCP, silicone induced higher levels of certain inflammatory and chemotactic cytokines in M0, CAM, and AAM macrophage subsets.
Conclusively, it was shown that silicone has the ability to induce a pro-inflammatory state to different magnitudes dependent on the macrophage subsets. This priming of the macrophage phenotype by silicone could explain the incidence of severe foreign body complications observed in vivo.
In biomaterial development, the design of material surfaces that mimic the extra-cellular matrix (ECM) in order to achieve favorable cellular instruction is rather challenging. Collagen-type IV (Col-IV), the major scaffolding component of Basement Membranes (BM), a specialized ECM with multiple biological functions, has the propensity to form networks by self-assembly and supports adhesion of cells such as endothelial cells or stem cells. The preparation of biomimetic Col-IV network-like layers to direct cell responses is difficult. We hypothesize that the morphology of the layer, and especially the density of the available adhesion sites, regulates the cellular adhesion to the layer. The Langmuir monolayer technique allows for preparation of thin layers with precisely controlled packing density at the air-water (A-W) interface. Transferring these layers onto cell culture substrates using the Langmuir-Schafer (LS) technique should therefore provide a pathway for preparation of BM mimicking layers with controlled cell adherence properties. In situ characterization using ellipsometry and polarization modulation-infrared reflection absorption spectroscopy of Col-IV layer during compression at the A-W interface reveal that there is linear increase of surface molecule concentration with negligible orientational changes up to a surface pressure of 25 mN m(-1). Smooth and homogeneous Col-IV network-like layers are successfully transferred by LS method at 15 mN m(-1) onto poly(ethylene terephthalate) (PET), which is a common substrate for cell culture. In contrast, the organization of Col-IV on PET prepared by the traditionally employed solution deposition method results in rather inhomogeneous layers with the appearance of aggregates and multilayers. Progressive increase in the number of early adherent mesenchymal stem cells (MSCs) after 24 h by controlling the areal Col-IV density by LS transfer at 10, 15 and 20 mN m(-1) on PET is shown. The LS method offers the possibility to control protein characteristics on biomaterial surfaces such as molecular density and thereby, modulate cell responses.
Glycoproteins adsorbing on an implant upon contact with body fluids can affect the biological response in vitro and in vivo, depending on the type and conformation of the adsorbed biomacromolecules. However, this process is poorly characterized and so far not controllable. Here, protein monolayers of high molecular cohesion with defined density are transferred onto polymeric substrates by the Langmuir-Schaefer (LS) technique and were compared with solution deposition (SO) method. It is hypothesized that on polydimethylsiloxane (PDMS), a substrate with poor cell adhesion capacity, the fibronectin (FN) layers generated by the LS and SO methods will differ in their organization, subsequently facilitating differential stem cell adhesion behavior. Indeed, atomic force microscopy visualization and immunofluorescence images indicated that organization of the FN layer immobilized on PDMS was uniform and homogeneous. In contrast, FN deposited by SO method was rather heterogeneous with appearance of structures resembling protein aggregates. Human mesenchymal stem cells showed reduced absolute numbers of adherent cells, and the vinculin expression seemed to be higher and more homogenously distributed after seeding on PDMS equipped with FN by LS in comparison with PDMS equipped with FN by SO. These divergent responses could be attributed to differences in the availability of adhesion molecule ligands such as the Arg-Gly-Asp (RGD) peptide sequence presented at the interface. The LS method allows to control the protein layer characteristics, including the thickness and the protein orientation or conformation, which can be harnessed to direct stem cell responses to defined outcomes, including migration and differentiation. Copyright (c) 2016 John Wiley & Sons, Ltd.
Gelatin-based hydrogels offer various biochemical cues that support encapsulated cells and are therefore suitable as cell delivery vehicles in regenerative medicine. However, besides the biochemical signals, biomechanical cues are crucial to ensure an optimal support of encapsulated cells. Hence, we aimed to correlate the cellular response of encapsulated cells to macroscopic and microscopic elastic properties of glycidylmethacrylate (GMA)-functionalized gelatin-based hydrogels. To ensure that different observations in cellular behavior could be attributed to differences in elastic properties, an identical concentration as well as degree of functionalization of biopolymers was utilized to form covalently crosslinked hydrogels. Elastic properties were merely altered by varying the average gelatin-chain length. Hydrogels exhibited an increased degree of swelling and a decreased bulk elastic modulus G with prolonged autoclaving of the starting solution. This was accompanied by an increase of hydrogel mesh size and thus by a reduction of crosslinking density. Tougher hydrogels retained the largest amount of cells; however, they also interfered with cell viability. Softer gels contained a lower cell density, but supported cell elongation and viability. Observed differences could be partially attributed to differences in bulk properties, as high crosslinking densities interfere with diffusion and cell spreading and thus can impede cell viability. Interestingly, a microscopic elastic modulus in the range of native soft tissue supported cell viability and elongation best while ensuring a good cell entrapment. In conclusion, gelatin-based hydrogels providing a soft tissue-like microenvironment represent adequate cell delivery vehicles for tissue engineering approaches. Copyright (c) 2016 John Wiley & Sons, Ltd.
BACKGROUND: Thrombogenicity is one of the main parameters tested in vitro to evaluate the hemocompatibility of artificial surfaces. While the influence of the temperature on platelet aggregation has been addressed by several studies, the temperature influence on the adherence of platelets to body foreign surfaces as an important aspect of biomedical device handling has not yet been explored. Therefore, we analyzed the influence of two typically applied incubation-temperatures (22 degrees C and 37 degrees C) on the adhesion of platelets to biomaterials. MATERIAL AND METHODS: Thrombogenicity of three different polymers - medical grade poly(dimethyl siloxane) (PDMS), polytetrafluoroethylene (PTFE) and polyethylene terephthalate (PET) - were studied in an in vitro static test. Platelet adhesion was studied with stringently characterized blood from apparently healthy subjects. Collection of whole blood and preparation of platelet rich plasma (PRP) was carried out at room temperature (22 degrees C). PRP was incubated with the polymers either at 22 degrees C or 37 degrees C. Surface adherent platelets were fixed, fluorescently labelled and assessed by an image-based approach. RESULTS AND DISCUSSION: Differences in the density of adherent platelets after incubation at 22 degrees C and 37 degrees C occurred on PDMS and PET. Similar levels of adherent platelets were observed on the very thrombogenic PTFE. The covered surface areas per single platelet were analyzed to measure the state of platelet activation and revealed no differences between the two incubation temperatures for any of the analyzed polymers. Irrespective of the observed differences between the low and medium thrombogenic PDMS and PET and the higher variability at 22 degrees C, the thrombogenicity of the three investigated polymers was evaluated being comparable at both incubation temperatures.
On the basis of the clinical studies in patients with coronary artery disease (CAD) presenting an increased percentage of activated platelets, we hypothesized that hemocompatibility testing utilizing platelets from healthy individuals may result in an underestimation of the materials' thrombogenicity. Therefore, we investigated the interaction of polymer-based biomaterials with platelets from CAD patients in comparison to platelets from apparently healthy individuals. In vitro static thrombogenicity tests revealed that adherent platelet densities and total platelet covered areas were significantly increased for the low (polydimethylsiloxane, PDMS) and medium (Collagen) thrombogenic surfaces in the CAD group compared to the healthy subjects group. The area per single platelet—indicating the spreading and activation of the platelets—was markedly increased on PDMS treated with PRP from CAD subjects. This could not be observed for collagen or polytetrafluoroethylene (PTFE). For the latter material, platelet adhesion and surface coverage did not differ between the two groups. Irrespective of the substrate, the variability of these parameters was increased for CAD patients compared to healthy subjects. This indicates a higher reactivity of platelets from CAD patients compared to the healthy individuals. Our results revealed, for the first time, that utilizing platelets from apparently healthy donors bears the risk of underestimating the thrombogenicity of polymer-based biomaterials.
The short- and long-term thrombogenicity of implant materials is still unpredictable, which is a significant challenge for the treatment of cardiovascular diseases. A knowledge-based approach for implementing biofunctions in materials requires a detailed understanding of the medical device in the biological system. In particular, the interplay between material and blood components/cells as well as standardized and commonly acknowledged in vitro test methods allowing a reproducible categorization of the material thrombogenicity requires further attention. Here, the status of in vitro thrombogenicity testing methods for biomaterials is reviewed, particularly taking in view the preparation of test materials and references, the selection and characterization of donors and blood samples, the prerequisites for reproducible approaches and applied test systems. Recent joint approaches in finding common standards for a reproducible testing are summarized and perspectives for a more disease oriented in vitro thrombogenicity testing are discussed.