Refine
Has Fulltext
- no (5)
Year of publication
- 2019 (5) (remove)
Document Type
- Article (5) (remove)
Language
- English (5)
Is part of the Bibliography
- yes (5)
Keywords
Institute
Enzyme immobilization using nanomaterials offers new approaches to enhanced bioelectrochemical performance and is essential for the preparation of bioelectrodes with high reproducibility and low cost. In this report, we describe the development of new three-dimensional (3D) bioelectrodes by immobilizing a "bioink" of glucose oxidase (GOD) in a matrix of reduced graphene oxides (RGOs), polyethylenimine (PEI), and ferrocene carboxylic acid (FcCOOH) on carbon paper (CP). CP with 3D interwoven carbon fibers serves as a solid porous and electronically conducting skeleton, providing large surface areas and space for loading the bioink and diffusion of substrate molecules, respectively. RGO enhances contact between the GOD-matrix and CP, maintaining high conductivity. The composition of the bioink has been systematically optimized. The GOD bioelectrodes show linearly increasing electrocatalytic oxidation current toward glucose concentration up to 48 mM. A hybrid enzymatic biofuel cell equipped with the GOD bioelectrode as a bioanode and a platinum cathode furthermore registers a maximum power density of 5.1 mu W cm(-2) and an open circuit voltage of 0.40 V at 25 degrees C. The new method reported of preparing a bioelectrode by drop-casting the bioink onto the substrate electrode is facile and versatile, with the potential of application also for other enzymatic bioelectrodes.
We have developed a three-dimensional (3D) graphene electrode suitable for the immobilization of human sulfite oxidase (hSO), which catalyzes the electrochemical oxidation of sulfite via direct electron transfer (DET). The electrode is fabricated by drop-casting graphene-polyethylenimine (G-P) composites on carbon papers (CPs) precoated with graphene oxide (GO). The negatively charged hSO can be adsorbed electrostatically on the positively charged matrix (G-P) on CP electrodes coated with GO (CPG), with a proper orientation for accelerated DET. Notably, further electrochemical reduction of G-P on CPG electrodes leads to a 9-fold increase of the saturation catalytic current density (j(m)) for sulfite oxidation reaching 24.4 +/- 0.3 mu A to cm(-2), the highest value among reported DET-based hSO bioelectrodes. The increased electron transfer rate plays a dominating role in the enhancement of direct enzymatic current because of the improved electric contact of hSO with the electrode, The optimized hSO bioelectrode shows a significant catalytic rate (k(cat): 25.6 +/- 0.3 s(-1)) and efficiency (k(cat)/K-m: 0.231 +/- 0.003 s(-1) mu M-1) compared to the reported hSO bioelectrodes. The assembly of the hSO bioanode and a commercial platinum biocathode allows the construction of sulfite/O-2 enzymatic biofuel cells (EBFCs) with flowing fuels. The optimized EBFC displays an open-circuit voltage (OCV) of 0.64 +/- 0.01 V and a maximum power density of 61 +/- 6 mu W cm(-2) (122 +/- 12 mW m(-3)) at 30 degrees C, which exceeds the best reported value by more than 6 times.
Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range.
A new approach for synthesizing a vectorially imprinted polymer (VIP) is presented for the microbial cytochrome P450cam enzyme. A surface attached binding motif of a natural reaction partner of the target protein, putidaredoxin (Pdx), is the anchor to the underlying transducer. The 15 amino acid peptide anchor, which stems from the largest continuous amino acid chain within the binding site of Pdx was modified: (i) internal cysteines were replaced by serines to prevent disulfide bond formation; (ii) 2 ethylene glycol units were attached to the N-terminus as a spacer region; and (iii) an N-terminal cysteine was added to allow the immobilization on the gold electrode surface. Immobilization on GCE was achieved via an N-(1-pyrenyl)maleimide (NPM) cross-linker. In this way oriented immobilization of P450cam was accomplished by binding it to a peptide-modified gold or glassy carbon electrode (GCE) prior to the electrosynthesis of a polymer nanofilm around the immobilized target. This VIP nanofilm enabled reversible oriented docking of P450cam as it is indicated by the catalytic oxygen reduction via direct electron transfer between the enzyme and the underlying electrode. Catalysis of oxygen reduction by P450cam bound to the VIP-modified GCE was used to measure rebinding to the VIP. The mild coupling of an oxidoreductase with the electrode may be appropriate for realizing electrode-driven substrate conversion by instable P450 enzymes without the need of NADPH co-factor.
For the early detection of bacterial infection, there is a need for rapid, sensitive, and label-free assays. Thus, in this study, nanostrucured microbial electrochemical platform is designed to monitor the viability and cell growth of S. aureus. Using multi-walled carbon nanotube modified screen-printed electrodes (MWCNTs/SPE), the cyclic voltammetric measurements showed only one irreversible oxidation peak at 600 mV vs Ag/AgCl that accounts for the viable and metabolically active bacterial cells. The assay was optimized and the secreted metabolites, in the extracellular matrix, were directly detected. The peak current showed a positive correlation with viable cell numbers ranging from OD600 nm of 0.1 to 1.1, indicating that the activity of live cells can be quantified. Consequently, responses of viable and non-viable cells of S. aureus to the effects of antibiotic and respiratory chain inhibitors were determined. Thus, the proposed nanostructure-based bacterial sensor provides a reasonable and reliable way for real-time monitoring of live-dead cell functions, and antibacterial profiling.