Refine
Year of publication
Document Type
- Article (30)
- Postprint (10)
- Conference Proceeding (8)
- Other (4)
- Doctoral Thesis (1)
Language
- English (53)
Is part of the Bibliography
- yes (53)
Keywords
- EMG (8)
- sonography (5)
- achilles tendinopathy (4)
- kinematics (4)
- Achilles and patellar tendon (3)
- Stumbling (3)
- advanced dynamic flow (3)
- electromyography (3)
- low back pain (3)
- non-athletes (3)
Institute
- Department Sport- und Gesundheitswissenschaften (41)
- Strukturbereich Kognitionswissenschaften (6)
- Extern (3)
- Hochschulambulanz (3)
- Humanwissenschaftliche Fakultät (2)
- Department Psychologie (1)
- Fakultät für Gesundheitswissenschaften (1)
- Gesundheitsmanagement (1)
- Institut für Ernährungswissenschaft (1)
Background Recent shoulder injury prevention programs have utilized resistance exercises combined with different forms of instability, with the goal of eliciting functional adaptations and thereby reducing the risk of injury. However, it is still unknown how an unstable weight mass (UWM) affects the muscular activity of the shoulder stabilizers. Aim of the study was to assess neuromuscular activity of dynamic shoulder stabilizers under four conditions of stable and UWM during three shoulder exercises. It was hypothesized that a combined condition of weight with UWM would elicit greater activation due to the increased stabilization demand. Methods Sixteen participants (7 m/9 f) were included in this cross-sectional study and prepared with an EMG-setup for the: Mm. upper/lower trapezius (U.TA/L.TA), lateral deltoid (DE), latissimus dorsi (LD), serratus anterior (SA) and pectoralis major (PE). A maximal voluntary isometric contraction test (MVIC; 5 s.) was performed on an isokinetic dynamometer. Next, internal/external rotation (In/Ex), abduction/adduction (Ab/Ad) and diagonal flexion/extension (F/E) exercises (5 reps.) were performed with four custom-made-pipes representing different exercise conditions. First, the empty-pipe (P; 0.5 kg) and then, randomly ordered, water-filled-pipe (PW; 1 kg), weight-pipe (PG; 4.5 kg) and weight + water-filled-pipe (PWG; 4.5 kg), while EMG was recorded. Raw root-mean-square values (RMS) were normalized to MVIC (%MVIC). Differences between conditions for RMS%MVIC, scapular stabilizer (SR: U.TA/L.TA; U.TA/SA) and contraction (CR: concentric/eccentric) ratios were analyzed (paired t-test; p <= 0.05; Bonferroni adjusted alpha = 0.008). Results PWG showed significantly greater muscle activity for all exercises and all muscles except for PE compared to P and PW. Condition PG elicited muscular activity comparable to PWG (p > 0.008) with significantly lower activation of L.TA and SA in the In/Ex rotation. The SR ratio was significantly higher in PWG compared to P and PW. No significant differences were found for the CR ratio in all exercises and for all muscles. Conclusion Higher weight generated greater muscle activation whereas an UWM raised the neuromuscular activity, increasing the stabilization demands. Especially in the In/Ex rotation, an UWM increased the RMS%MVIC and SR ratio. This might improve training effects in shoulder prevention and rehabilitation programs.
Background Recent shoulder injury prevention programs have utilized resistance exercises combined with different forms of instability, with the goal of eliciting functional adaptations and thereby reducing the risk of injury. However, it is still unknown how an unstable weight mass (UWM) affects the muscular activity of the shoulder stabilizers. Aim of the study was to assess neuromuscular activity of dynamic shoulder stabilizers under four conditions of stable and UWM during three shoulder exercises. It was hypothesized that a combined condition of weight with UWM would elicit greater activation due to the increased stabilization demand. Methods Sixteen participants (7 m/9 f) were included in this cross-sectional study and prepared with an EMG-setup for the: Mm. upper/lower trapezius (U.TA/L.TA), lateral deltoid (DE), latissimus dorsi (LD), serratus anterior (SA) and pectoralis major (PE). A maximal voluntary isometric contraction test (MVIC; 5 s.) was performed on an isokinetic dynamometer. Next, internal/external rotation (In/Ex), abduction/adduction (Ab/Ad) and diagonal flexion/extension (F/E) exercises (5 reps.) were performed with four custom-made-pipes representing different exercise conditions. First, the empty-pipe (P; 0.5 kg) and then, randomly ordered, water-filled-pipe (PW; 1 kg), weight-pipe (PG; 4.5 kg) and weight + water-filled-pipe (PWG; 4.5 kg), while EMG was recorded. Raw root-mean-square values (RMS) were normalized to MVIC (%MVIC). Differences between conditions for RMS%MVIC, scapular stabilizer (SR: U.TA/L.TA; U.TA/SA) and contraction (CR: concentric/eccentric) ratios were analyzed (paired t-test; p <= 0.05; Bonferroni adjusted alpha = 0.008). Results PWG showed significantly greater muscle activity for all exercises and all muscles except for PE compared to P and PW. Condition PG elicited muscular activity comparable to PWG (p > 0.008) with significantly lower activation of L.TA and SA in the In/Ex rotation. The SR ratio was significantly higher in PWG compared to P and PW. No significant differences were found for the CR ratio in all exercises and for all muscles. Conclusion Higher weight generated greater muscle activation whereas an UWM raised the neuromuscular activity, increasing the stabilization demands. Especially in the In/Ex rotation, an UWM increased the RMS%MVIC and SR ratio. This might improve training effects in shoulder prevention and rehabilitation programs.
Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 +/- 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean SD) and statistical testing for group differences was performed (cy = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 +/- 0.7 mm/5.6 +/- 0.7 mm) nor in controls (4.8 +/- 0.4 mm/4.9 +/- 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (Ml: 3.5 +/- 0.5 mm, M2: 3.8 +/- 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p <= 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports.
Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports.
Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports.
Background: Low back pain (LBP) is one of the world wide leading causes of limited activity and disability. Impaired motor control has been found to be one of the possible factors related to the development or persistence of LBP. In particularly, motor control strategies seemed to be altered in situations requiring reactive responses of the trunk counteracting sudden external forces. However, muscular responses were mostly assessed in (quasi) static testing situations under simplified laboratory conditions. Comprehensive investigations in motor control strategies during dynamic everyday situations are lacking. The present research project aimed to investigate muscular compensation strategies following unexpected gait perturbations in people with and without LBP. A novel treadmill stumbling protocol was tested for its validity and reliability to provoke muscular reflex responses at the trunk and the lower extremities (study 1). Thereafter, motor control strategies in response to sudden perturbations were compared between people with LBP and asymptomatic controls (CTRL) (study 2). In accordance with more recent concepts of motor adaptation to pain, it was hypothesized that pain may have profound consequences on motor control strategies in LBP. Therefore, it was investigated whether differences in compensation strategies were either consisting of changes local to the painful area at the trunk, or also being present in remote areas such as at the lower extremities.
Methods: All investigations were performed on a custom build split-belt treadmill simulating trip-like events by unexpected rapid deceleration impulses (amplitude: 2 m/s; duration: 100 ms; 200 ms after heel contact) at 1m/s baseline velocity. A total number of 5 (study 1) and 15 (study 2) right sided perturbations were applied during walking trials. Muscular activities were assessed by surface electromyography (EMG), recorded at 12 trunk muscles and 10 (study 1) respectively 5 (study 2) leg muscles. EMG latencies of muscle onset [ms] were retrieved by a semi-automatic detection method. EMG amplitudes (root mean square (RMS)) were assessed within 200 ms post perturbation, normalized to full strides prior to any perturbation [RMS%]. Latency and amplitude investigations were performed for each muscle individually, as well as for pooled data of muscles grouped by location. Characteristic pain intensity scores (CPIS; 0-100 points, von Korff) based on mean intensity ratings reported for current, worst and average pain over the last three months were used to allocate participants into LBP (≥30 points) or CTRL (≤10 points). Test-retest reproducibility between measurements was determined by a compilation of measures of reliability. Differences in muscular activities between LBP and CTRL were analysed descriptively for individual muscles; differences based on grouped muscles were statistically tested by using a multivariate analysis of variance (MANOVA, α =0.05).
Results: Thirteen individuals were included into the analysis of study 1. EMG latencies revealed reflex muscle activities following the perturbation (mean: 89 ms). Respective EMG amplitudes were on average 5-fold of those assessed in unperturbed strides, though being characterized by a high inter-subject variability. Test-retest reliability of muscle latencies showed a high reproducibility, both for muscles at the trunk and legs. In contrast, reproducibility of amplitudes was only weak to moderate for individual muscles, but increased when being assessed as a location specific outcome summary of grouped muscles. Seventy-six individuals were eligible for data analysis in study 2. Group allocation according to CPIS resulted in n=25 for LBP and n=29 for CTRL. Descriptive analysis of activity onsets revealed longer delays for all muscles within LBP compared to CTRL (trunk muscles: mean 10 ms; leg muscles: mean 3 ms). Onset latencies of grouped muscles revealed statistically significant differences between LBP and CTRL for right (p=0.009) and left (p=0.007) abdominal muscle groups. EMG amplitude analysis showed a high variability in activation levels between individuals, independent of group assignment or location. Statistical testing of grouped muscles indicated no significant difference in amplitudes between LBP and CTRL.
Discussion: The present research project could show that perturbed treadmill walking is suitable to provoke comprehensive reflex responses at the trunk and lower extremities, both in terms of sudden onsets and amplitudes of reflex activity. Moreover, it could demonstrate that sudden loadings under dynamic conditions provoke an altered reflex timing of muscles surrounding the trunk in people with LBP compared to CTRL. In line with previous investigations, compensation strategies seemed to be deployed in a task specific manner, with differences between LBP and CTRL being evident predominately at ventral sides. No muscular alterations exceeding the trunk could be found when being assessed under the automated task of locomotion. While rehabilitation programs tailored towards LBP are still under debate, it is tempting to urge the implementation of dynamic sudden loading incidents of the trunk to enhance motor control and thereby to improve spinal protection. Moreover, in respect to the consistently observed task specificity of muscular compensation strategies, such a rehabilitation program should be rich in variety.
Instrumented treadmills offer the potential to generate standardized walking perturbations, which are particularly rapid and powerful. However, technical requirements to release adequate perturbations regarding timing, duration and amplitude are demanding. This study investigated the test-retest reliability and validity of a new treadmill perturbation protocol releasing rapid and unexpected belt perturbations to provoke muscular reflex responses at lower extremities and the trunk. Fourteen healthy participants underwent two identical treadmill walking protocols, consisting of 10 superimposed one-sided belt perturbations (100 ms duration; 2 m/s amplitude), triggered by a plantar pressure insole 200 ms after heel contact. Delay, duration and amplitude of applied perturbations were recorded by 3D-motion capture. Muscular reflex responses (within 200 ms) were measured at lower extremities and the trunk (10-lead EMG). Data was analyzed descriptively (mean +/- SD). Reliability was analyzed using test-retest variability (TRV%) and limits of agreement (LoA, bias +/- 1.96*SD). Perturbation delay was 202 14 ms, duration was 102 +/- 4 ms and amplitude was 2.1 +/- 0.01 m/s. TRV for perturbation delay, duration and amplitude ranged from 5.0% to 5.7%. LoA reached 3 +/- 36 ms for delay, 2 +/- 13 ms for duration and 0.0 +/- 0.3 m/s for amplitude. EMG amplitudes following perturbations ranged between 106 +/- 97% and 909 +/- 979% of unperturbed gait and EMG latencies between 82 +/- 14 ms and 106 +/- 16 ms. Minor differences between preset and observed perturbation characteristics and results of test-retest analysis prove a high validity with excellent reliability of the setup. Therefore, the protocol tested can be recommended to provoke muscular reflex responses at lower extremities and the trunk in perturbed walking. (C) 2017 Elsevier Ltd. All rights reserved.
Eccentric exercise is discussed as a treatment option for clinical populations, but specific responses in terms of muscle damage and systemic inflammation after repeated loading of large muscle groups have not been conclusively characterized. Therefore, this study tested the feasibility of an isokinetic protocol for repeated maximum eccentric loading of the trunk muscles. Nine asymptomatic participants (5 f/4 m; 34±6 yrs; 175±13 cm; 76±17 kg) performed three isokinetic 2-minute all-out trunk strength tests (1x concentric (CON), 2x eccentric (ECC1, ECC2), 2 weeks apart; flexion/extension, 60°/s, ROM 55°). Outcomes were peak torque, torque decline, total work, and indicators of muscle damage and inflammation (over 168 h). Statistics were done using the Friedman test (Dunn’s post-test). For ECC1 and ECC2, peak torque and total work were increased and torque decline reduced compared to CON. Repeated ECC bouts yielded unaltered torque and work outcomes. Muscle damage markers were highest after ECC1 (soreness 48 h, creatine kinase 72 h; p<0.05). Their overall responses (area under the curve) were abolished post-ECC2 compared to post-ECC1 (p<0.05). Interleukin-6 was higher post-ECC1 than CON, and attenuated post-ECC2 (p>0.05). Interleukin-10 and tumor necrosis factor-α were not detectable. All markers showed high inter-individual variability. The protocol was feasible to induce muscle damage indicators after exercising a large muscle group, but the pilot results indicated only weak systemic inflammatory responses in asymptomatic adults.
Eccentric exercise is discussed as a treatment option for clinical populations, but specific responses in terms of muscle damage and systemic inflammation after repeated loading of large muscle groups have not been conclusively characterized. Therefore, this study tested the feasibility of an isokinetic protocol for repeated maximum eccentric loading of the trunk muscles. Nine asymptomatic participants (5 f/4 m; 34±6 yrs; 175±13 cm; 76±17 kg) performed three isokinetic 2-minute all-out trunk strength tests (1x concentric (CON), 2x eccentric (ECC1, ECC2), 2 weeks apart; flexion/extension, 60°/s, ROM 55°). Outcomes were peak torque, torque decline, total work, and indicators of muscle damage and inflammation (over 168 h). Statistics were done using the Friedman test (Dunn’s post-test). For ECC1 and ECC2, peak torque and total work were increased and torque decline reduced compared to CON. Repeated ECC bouts yielded unaltered torque and work outcomes. Muscle damage markers were highest after ECC1 (soreness 48 h, creatine kinase 72 h; p<0.05). Their overall responses (area under the curve) were abolished post-ECC2 compared to post-ECC1 (p<0.05). Interleukin-6 was higher post-ECC1 than CON, and attenuated post-ECC2 (p>0.05). Interleukin-10 and tumor necrosis factor-α were not detectable. All markers showed high inter-individual variability. The protocol was feasible to induce muscle damage indicators after exercising a large muscle group, but the pilot results indicated only weak systemic inflammatory responses in asymptomatic adults.
Background and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 +/- 4 years, height 177 +/- 11 cm, weight 73 +/- 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficients (ICC), root mean square error (RMSE) and Bland and Altmann analysis (bias; upper and lower limits of agreement). Results ROM and TROM analysis revealed inconsistent validity during simple (ICC: 0.040-0.733, RMSE: 9.7 degrees-20.3 degrees, bias: 1.2 degrees-50.7 degrees) and insufficient agreement during complex shoulder movements (ICC: 0.104-0.453, RMSE: 10.1 degrees-23.3 degrees, bias: 1.0 degrees-55.9 degrees). Peak angular velocity (ICC: 0.202-0.865, RMSE: 14.6 degrees/s-26.7 degrees/s, bias: 10.2 degrees/s-29.9 degrees/s) and mean angular velocity (ICC: 0.019-0.786, RMSE:6.1 degrees/s-34.2 degrees/s, bias: 1.6 degrees/s-27.8 degrees/s) were inconsistent. Conclusions The "off-the-shelf" sensor-software system showed overall insufficient agreement with the gold standard. Further development of commercial IMU-software-solutions may increase measurement accuracy and permit their integration into everyday clinical practice.
Background and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 +/- 4 years, height 177 +/- 11 cm, weight 73 +/- 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficients (ICC), root mean square error (RMSE) and Bland and Altmann analysis (bias; upper and lower limits of agreement). Results ROM and TROM analysis revealed inconsistent validity during simple (ICC: 0.040-0.733, RMSE: 9.7 degrees-20.3 degrees, bias: 1.2 degrees-50.7 degrees) and insufficient agreement during complex shoulder movements (ICC: 0.104-0.453, RMSE: 10.1 degrees-23.3 degrees, bias: 1.0 degrees-55.9 degrees). Peak angular velocity (ICC: 0.202-0.865, RMSE: 14.6 degrees/s-26.7 degrees/s, bias: 10.2 degrees/s-29.9 degrees/s) and mean angular velocity (ICC: 0.019-0.786, RMSE:6.1 degrees/s-34.2 degrees/s, bias: 1.6 degrees/s-27.8 degrees/s) were inconsistent. Conclusions The "off-the-shelf" sensor-software system showed overall insufficient agreement with the gold standard. Further development of commercial IMU-software-solutions may increase measurement accuracy and permit their integration into everyday clinical practice.
Background Recent studies indicate the existence of a repeated bout effect on the contralateral untrained limb following eccentric and isometric contractions. Aims This review aims to summarize the evidence for magnitude, duration and differences of this effect following isometric and eccentric preconditioning exercises. Methods Medline, Cochrane, and Web of science were searched from January 1971 until September 2020. Randomized controlled trials, case-control studies and cross-sectional studies were identified by combining keywords and synonyms (e.g., "contralateral", "exercise", "preconditioning", "protective effect"). At least two of the following outcome parameters were mandatory for study inclusion: strength, muscle soreness, muscle swelling, limb circumference, inflammatory blood markers or protective index (relative change of aforementioned measures). Results After identifying 1979 articles, 13 studies were included. Most investigations examined elbow flexors and utilized eccentric isokinetic protocols to induce the contralateral repeated bout effect. The magnitude of protection was observed in four studies, smaller values of the contralateral when compared to the ipsilateral repeated bout effect were noted in three studies. The potential mechanism is thought to be of neural central nature since no differences in peripheral muscle activity were observed. Time course was examined in three investigations. One study showed a smaller protective effect following isometric preconditioning when compared to eccentric preconditioning exercises. Conclusions The contralateral repeated bout effect demonstrates a smaller magnitude and lasts shorter than the ipsilateral repeated bout effect. Future research should incorporate long-term controlled trials including larger populations to identify central mechanisms. This knowledge should be used in clinical practice to prepare immobilized limbs prospectively for an incremental load.
Investigating of locomotor disturbances are relevant in human injury and performance. Therefore, lower extremity kinematics were analysed in response to decelerative perturbations during running using statistical parametric mapping (SPM). 13 asymptomatic individuals (8 females & 5 males, 28 +/- 3 years, 171 +/- 9 cm, 68 +/- 10 kg) completed an 8-minute running protocol with 30 one-sided perturbations (15 each side) to generate decelerative disturbances.
A 3D-motion capture system was employed to record kinematic data. Joint angles of the ankle, knee, and hip in addition to stride duration, stride length and step width were calculated for leading and trailing strides.
Results were analysed descriptively, followed by SPM of paired t-tests (P < 0.025). Reactively (after perturbation), perturbations caused decreased hip adduction and stride duration of the leading leg. The trailing leg reacted with ankle inversion, knee and hip flexion, hip abduction, as well as an increase in stride duration and step width (P < 0.025). In preparation for perturbation, the trailing leg reduced ankle dorsiflexion, knee flexion, hip flexion, and adduction. In summary, applied perturbations produced substantial reactive (feedback) and predictive (feedforward) responses of the lower limbs, most apparent in the trailing leg.
Effects of exercise treatment on functional outcome parameters in mid-portion achilles tendinopathy
(2023)
Exercise interventions are evident in the treatment of mid-portion Achilles tendinopathy (AT). However, there is still a lack of knowledge concerning the effect of different exercise treatments on improving a specific function (e.g., strength) in this population. Thus, this study aimed to systematically review the effect of exercise treatments on different functional outcomes in mid-portion AT. An electronic database of Pubmed, Web of Science, and Cochrane Central Register of Controlled Trials were searched from inception to 21 February 2023. Studies that investigated changes in plantar flexor function with exercise treatments were considered in mid-portion AT. Only randomized controlled trials (RCTs) and clinical controlled trials (CCTs) were included. Functional outcomes were classified by kinetic (e.g., strength), kinematic [e.g., ankle range of motion (ROM)], and sensorimotor (e.g., balance index) parameters. The types of exercise treatments were classified into eccentric, concentric, and combined (eccentric plus concentric) training modes. Quality assessment was appraised using the Physiotherapy Evidence Database scale for RCTs, and the Joanna Briggs Institute scale for CCTs. The search yielded 2,260 records, and a total of ten studies were included. Due to the heterogeneity of the included studies, a qualitative synthesis was performed. Eccentric training led to improvements in power outcomes (e.g., height of countermovement jump), and in strength outcomes (e.g., peak torque). Concentric training regimens showed moderate enhanced power outcomes. Moreover, one high-quality study showed an improvement in the balance index by eccentric training, whereas the application of concentric training did not. Combined training modalities did not lead to improvements in strength and power outcomes. Plantarflexion and dorsiflexion ROM measures did not show relevant changes by the exercise treatments. In conclusion, eccentric training is evident in improving strength outcomes in AT patients. Moreover, it shows moderate evidence improvements in power and the sensorimotor parameter "balance index". Concentric training presents moderate evidence in the power outcomes and can therefore be considered as an alternative to improve this function. Kinematic analysis of plantarflexion and dorsiflexion ROM might not be useful in AT people. This study expands the knowledge what types of exercise regimes should be considered to improve the functional outcomes in AT.
Reliability of ultrasound measurements for subcutaneous adipose tissue in elite canoe athletes
(2014)
Subcutaneous adipose tissue (SAT) measurements with ultrasound have recently been introduced to assess body fat in elite athletes. However, appropriate protocols and data on various groups of athletes are missing. We investigated intra-rater reliability of SAT measurements using ultrasound in elite canoe athletes. 25 international level canoeists (18 male, 7 female; 23 +/- 4 years; 81 +/- 11 kg; 1.83 +/- 0.09 m; 20 +/- 3 training h/wk) were measured on 2 consecutive days. SAT was assessed with B-mode ultrasound at 8 sites (ISAK): triceps, subscapular, biceps, iliac crest, supraspinal, abdominal, front thigh, medial calf, and quantified using image analysis software. Data was analyzed descriptively (mean +/- SD, [range]). Coefficient of variation (CV %), intraclass correlation coefficient (ICC, 2.1) and absolute (LoA) and ratio limits of agreement (RLoA) were calculated for day-to-day reliability. Mean sum of SAT thickness was 30.0 +/- 19.4 mm [8.0, 80.1 mm], with 3.9 +/- 1.8 mm [1.2 mm subscapular, 8.0 mm abdominal] for individual sites. CV for the sum of sites was 4.7 %, ICC 0.99, LoA 1.7 +/- 3.6 mm, RLoA 0.940 (*/divided by 1.155). Measuring SAT with ultrasound has proved to have excellent day-to-day reliability in elite canoe athletes. Recommendations for standardization of the method will further increase accuracy and reproducibility.