Refine
Year of publication
Document Type
- Article (25)
- Postprint (19)
- Doctoral Thesis (1)
- Habilitation Thesis (1)
Is part of the Bibliography
- yes (46)
Keywords
- Adaptive Force (13)
- isometric muscle action (9)
- maximal isometric Adaptive Force (6)
- Holding isometric muscle action (5)
- Mechanotendography (5)
- O2C spectrophotometer (5)
- Pushing isometric muscle action (5)
- hemoglobin amount (5)
- adaptive force (4)
- holding capacity (4)
- holding isometric muscle action (HIMA) (4)
- mechanical tendinous oscillations (4)
- motor control (4)
- neuromuscular control (4)
- time (4)
- Mechanomyography (3)
- Two forms of isometric muscle action (3)
- blood flow (3)
- capillary recruitment (3)
- muscle action (3)
- muscle oxygen saturation (3)
- muscle weakness (3)
- pulling isometric muscle action (PIMA) (3)
- synchronization (3)
- Isometric contraction (2)
- Isometric muscle action (2)
- Microvascular blood filling (2)
- Muscle twitch (2)
- Oxygen saturation (2)
- Pulling isometric muscle action (2)
- Time to task failure (2)
- activation (2)
- adaptation to external force impact (2)
- adaptive holding capacity (2)
- biomechanical parameter (2)
- contractions (2)
- eccentric muscle action (2)
- electroencephalography (EEG) (2)
- emotional imagery (2)
- emotions (2)
- force (2)
- force profiles (2)
- hand (2)
- handheld device (2)
- holding (HIMA) and pushing (PIMA) isometric muscle action (2)
- holding capability (2)
- humans (2)
- impact on pre-activated Achilles tendon (2)
- injury mechanisms (2)
- inter-brain synchronization (2)
- inter-muscle-brain synchronization (2)
- interpersonal muscle action (2)
- isometric eccentric force (2)
- lengthening contractions (2)
- load (2)
- magnetoencephalography (2)
- manual muscle test (2)
- manual muscle testing (2)
- maximal voluntary contraction (2)
- mechanomyography (MMG) (2)
- mechanotendography (2)
- motor unit synchronization (2)
- muscle (2)
- muscle function (2)
- muscle oxygenation (2)
- muscular activity (2)
- neural-control (2)
- neuromuscular adaptation (2)
- neuromuscular diagnostics (2)
- neuromuscular functionality (2)
- neuromuscular pre-activation (2)
- oscillations (2)
- piezo-based measurement system (2)
- pleasant and unpleasant imagery (2)
- post COVID syndrome (2)
- power (2)
- power improvement (2)
- principles (2)
- pushing isometric muscle action (PIMA) (2)
- reliability (2)
- repeated adaptive isometric–eccentric muscle action (2)
- reproducibility (2)
- sensorimotor control (2)
- strength measurement system (2)
- strength vs. endurance athletes (2)
- systems (2)
- task (2)
- task failure (2)
- tendons (2)
- validity (2)
- variability (2)
- wavelet coherence (2)
- Diseases (1)
- Emotions (1)
- Functional weakness (1)
- Holding (1)
- Holding capacity (1)
- Imaginations (1)
- Interaktion (1)
- Isometric Adaptive Force (1)
- Isometrie (1)
- Long COVID (1)
- Manual muscle test (1)
- Mechanomyografie (1)
- Motor control (1)
- Neurology (1)
- Neuroscience (1)
- Synchronisation (1)
- case report (1)
- fatigue (1)
- holding (1)
- individualized pulsed electromagnetic field (1)
- interaction (1)
- isometric muscle action (HIMA) (1)
- isometric-eccentric force (1)
- long COVID (1)
- long COVID fatigue (1)
- mechanomyography (1)
- muscular holding capacity (1)
- myofascial oscillations (1)
- myofasziale Oszillationen (1)
- pneumatic force measuring system (1)
- post-COVID syndrome (1)
Long COVID patients show symptoms, such as fatigue, muscle weakness and pain. Adequate diagnostics are still lacking. Investigating muscle function might be a beneficial approach. The holding capacity (maximal isometric Adaptive Force; AFisomax) was previously suggested to be especially sensitive for impairments. This longitudinal, non-clinical study aimed to investigate the AF in long COVID patients and their recovery process. AF parameters of elbow and hip flexors were assessed in 17 patients at three time points (pre: long COVID state, post: immediately after first treatment, end: recovery) by an objectified manual muscle test. The tester applied an increasing force on the limb of the patient, who had to resist isometrically for as long as possible. The intensity of 13 common symptoms were queried. At pre, patients started to lengthen their muscles at ~50% of the maximal AF (AFmax), which was then reached during eccentric motion, indicating unstable adaptation. At post and end, AFisomax increased significantly to ~99% and 100% of AFmax, respectively, reflecting stable adaptation. AFmax was statistically similar for all three time points. Symptom intensity decreased significantly from pre to end. The findings revealed a substantially impaired maximal holding capacity in long COVID patients, which returned to normal function with substantial health improvement. AFisomax might be a suitable sensitive functional parameter to assess long COVID patients and to support therapy process
Long COVID patients show symptoms, such as fatigue, muscle weakness and pain. Adequate diagnostics are still lacking. Investigating muscle function might be a beneficial approach. The holding capacity (maximal isometric Adaptive Force; AFisomax) was previously suggested to be especially sensitive for impairments. This longitudinal, non-clinical study aimed to investigate the AF in long COVID patients and their recovery process. AF parameters of elbow and hip flexors were assessed in 17 patients at three time points (pre: long COVID state, post: immediately after first treatment, end: recovery) by an objectified manual muscle test. The tester applied an increasing force on the limb of the patient, who had to resist isometrically for as long as possible. The intensity of 13 common symptoms were queried. At pre, patients started to lengthen their muscles at ~50% of the maximal AF (AFmax), which was then reached during eccentric motion, indicating unstable adaptation. At post and end, AFisomax increased significantly to ~99% and 100% of AFmax, respectively, reflecting stable adaptation. AFmax was statistically similar for all three time points. Symptom intensity decreased significantly from pre to end. The findings revealed a substantially impaired maximal holding capacity in long COVID patients, which returned to normal function with substantial health improvement. AFisomax might be a suitable sensitive functional parameter to assess long COVID patients and to support therapy process
Synchronisationsphänomene myotendinöser Oszillationen interagierender neuromuskulärer Systeme
(2014)
Muskeln oszillieren nachgewiesener Weise mit einer Frequenz um 10 Hz. Doch was geschieht mit myofaszialen Oszillationen, wenn zwei neuromuskuläre Systeme interagieren? Die Dissertation widmet sich dieser Fragestellung bei isometrischer Interaktion. Während der Testmessungen ergaben sich Hinweise für das Vorhandensein von möglicherweise zwei verschiedenen Formen der Isometrie. Arbeiten zwei Personen isometrisch gegeneinander, können subjektiv zwei Modi eingenommen werden: man kann entweder isometrisch halten – der Kraft des Partners widerstehen – oder isometrisch drücken – gegen den isometrischen Widerstand des Partners arbeiten. Daher wurde zusätzlich zu den Messungen zur Interaktion zweier Personen an einzelnen Individuen geprüft, ob möglicherweise zwei Formen der Isometrie existieren. Die Promotion besteht demnach aus zwei inhaltlich und methodisch getrennten Teilen: I „Single-Isometrie“ und II „Paar-Isometrie“. Für Teil I wurden mithilfe eines pneumatisch betriebenen Systems die hypothetischen Messmodi Halten und Drücken während isometrischer Aktion untersucht. Bei n = 10 Probanden erfolgte parallel zur Aufzeichnung des Drucksignals während der Messungen die Erfassung der Kraft (DMS) und der Beschleunigung sowie die Aufnahme der mechanischen Muskeloszillationen folgender myotendinöser Strukturen via Mechanomyo- (MMG) bzw. Mechanotendografie (MTG): M. triceps brachii (MMGtri), Trizepssehne (MTGtri), M. obliquus externus abdominis (MMGobl). Pro Proband wurden bei 80 % der MVC sowohl sechs 15-Sekunden-Messungen (jeweils drei im haltenden bzw. drückenden Modus; Pause: 1 Minute) als auch vier Ermüdungsmessungen (jeweils zwei im haltenden bzw. drückenden Modus; Pause: 2 Minuten) durchgeführt. Zum Vergleich der Messmodi Halten und Drücken wurden die Amplituden der myofaszialen Oszillationen sowie die Kraftausdauer herangezogen. Signifikante Unterschiede zwischen dem haltenden und dem drückenden Modus zeigten sich insbesondere im Bereich der Ermüdungscharakteristik. So lassen Probanden im haltenden Modus signifikant früher nach als im drückenden Modus (t(9) = 3,716; p = .005). Im drückenden Modus macht das längste isometrische Plateau durchschnittlich 59,4 % der Gesamtdauer aus, im haltenden sind es 31,6 % (t(19) = 5,265, p = .000). Die Amplituden der Single-Isometrie-Messungen unterscheiden sich nicht signifikant. Allerdings variieren die Amplituden des MMGobl zwischen den Messungen im drückenden Modus signifikant stärker als im haltenden Modus. Aufgrund dieser teils signifikanten Unterschiede zwischen den beiden Messmodi wurde dieses Setting auch im zweiten Teil „Paar-Isometrie“ berücksichtigt. Dort wurden n = 20 Probanden – eingeteilt in zehn gleichgeschlechtliche Paare – während isometrischer Interaktion untersucht. Die Sensorplatzierung erfolgte analog zu Teil I. Die Oszillationen der erfassten MTG- sowie MMG-Signale wurden u.a. mit Algorithmen der Nichtlinearen Dynamik auf ihre Kohärenz hin untersucht. Durch die Paar-Isometrie-Messungen zeigte sich, dass die Muskeln und die Sehnen beider neuromuskulärer Systeme bei Interaktion im bekannten Frequenzbereich von 10 Hz oszillieren. Außerdem waren sie in der Lage, sich bei Interaktion so aufeinander abzustimmen, dass sich eine signifikante Kohärenz entwickelte, die sich von Zufallspaarungen signifikant unterscheidet (Patchanzahl: t(29) = 3,477; p = .002; Summe der 4 längsten Patches: t(29) = 7,505; p = .000). Es wird der Schluss gezogen, dass neuromuskuläre Komplementärpartner in der Lage sind, sich im Sinne kohärenten Verhaltens zu synchronisieren. Bezüglich der Parameter zur Untersuchung der möglicherweise vorhandenen zwei Formen der Isometrie zeigte sich bei den Paar-Isometrie-Messungen zwischen Halten und Drücken ein signifikanter Unterschied bei der Ermüdungscharakteristik sowie bezüglich der Amplitude der MMGobl. Die Ergebnisse beider Teilstudien bestärken die Hypothese, dass zwei Formen der Isometrie existieren. Fraglich ist, ob man überhaupt von Isometrie sprechen kann, da jede isometrische Muskelaktion aus feinen Oszillationen besteht, die eine per Definition postulierte Isometrie ausschließen. Es wird der Vorschlag unterbreitet, die Isometrie durch den Begriff der Homöometrie auszutauschen. Die Ergebnisse der Paar-Isometrie-Messungen zeigen u.a., dass neuromuskuläre Systeme in der Lage sind, ihre myotendinösen Oszillationen so aufeinander abzustimmen, dass kohärentes Verhalten entsteht. Es wird angenommen, dass hierzu beide neuromuskulären Systeme funktionell intakt sein müssen. Das Verfahren könnte für die Diagnostik funktioneller Störungen relevant werden.
The Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisomax) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisomax, and AFmax (maximal torque of one AF measurement) were evaluated regarding different considerations and statistical tests. AFmax and AFisomax declined in the course of 30 trials [slope regression (mean ± standard deviation): AFmax = −0.323 ± 0.263; AFisomax = −0.45 ± 0.45]. The decline from start to end amounted to −12.8% ± 8.3% (p < 0.001) for AFmax and −25.41% ± 26.40% (p < 0.001) for AFisomax. AF parameters declined more in strength vs. endurance athletes. Thereby, strength athletes showed a rather stable decline for AFmax and a plateau formation for AFisomax after 15 trials. In contrast, endurance athletes reduced their AFmax, especially after the first five trials, and remained on a rather similar level for AFisomax. The maximum of AFisomax of all 30 trials amounted 67.67% ± 13.60% of MVIC (p < 0.001, n = 12), supporting the hypothesis of two types of isometric muscle action (holding vs. pushing). The findings provided the first data on the behavior of torque parameters after repeated isometric–eccentric actions and revealed further insights into neuromuscular control strategies. Additionally, they highlight the importance of investigating AF parameters in athletes based on the different behaviors compared to MVIC. This is assumed to be especially relevant regarding injury mechanisms.
The Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisoₘₐₓ) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisoₘₐₓ, and AFₘₐₓ (maximal torque of one AF measurement) were evaluated regarding different considerations and statistical tests. AFₘₐₓ and AFisoₘₐₓ declined in the course of 30 trials [slope regression (mean ± standard deviation): AFₘₐₓ = −0.323 ± 0.263; AFisoₘₐₓ = −0.45 ± 0.45]. The decline from start to end amounted to −12.8% ± 8.3% (p < 0.001) for AFₘₐₓ and −25.41% ± 26.40% (p < 0.001) for AFisoₘₐₓ. AF parameters declined more in strength vs. endurance athletes. Thereby, strength athletes showed a rather stable decline for AFmax and a plateau formation for AFisoₘₐₓ after 15 trials. In contrast, endurance athletes reduced their AFₘₐₓ, especially after the first five trials, and remained on a rather similar level for AFisomax. The maximum of AFisoₘₐₓ of all 30 trials amounted 67.67% ± 13.60% of MVIC (p < 0.001, n = 12), supporting the hypothesis of two types of isometric muscle action (holding vs. pushing). The findings provided the first data on the behavior of torque parameters after repeated isometric–eccentric actions and revealed further insights into neuromuscular control strategies. Additionally, they highlight the importance of investigating AF parameters in athletes based on the different behaviors compared to MVIC. This is assumed to be especially relevant regarding injury mechanisms.
The pathophysiology of Parkinson’s disease (PD) is still not understood. There are investigations which show a changed oscillatory behaviour of brain circuits or changes in variability of, e.g., gait parameters in PD. The aim of this study was to investigate whether or not the motor output differs between PD patients and healthy controls. Thereby, patients without tremor are investigated in the medication off state performing a special bilateral isometric motor task. The force and accelerations (ACC) were recorded as well as the Mechanomyography (MMG) of the biceps brachii, the brachioradialis and of the pectoralis major muscles using piezoelectric-sensors during the bilateral motor task at 60% of the maximal isometric contraction. The frequency, a specific power ratio, the amplitude variation and the slope of amplitudes were analysed. The results indicate that the oscillatory behaviour of motor output in PD patients without tremor deviates from controls: thereby, the 95%-confidence-intervals of power ratio and of amplitude variation of all signals are disjoint between PD and controls and show significant differences in group comparisons (power ratio: p = 0.000–0.004, r = 0.441–0.579; amplitude variation: p = 0.000–0.001, r = 0.37–0.67). The mean frequency shows a significant difference for ACC (p = 0.009, r = 0.43), but not for MMG. It remains open, whether this muscular output reflects changes of brain circuits and whether the results are reproducible and specific for PD.
The pathophysiology of Parkinson’s disease (PD) is still not understood. There are investigations which show a changed oscillatory behaviour of brain circuits or changes in variability of, e.g., gait parameters in PD. The aim of this study was to investigate whether or not the motor output differs between PD patients and healthy controls. Thereby, patients without tremor are investigated in the medication off state performing a special bilateral isometric motor task. The force and accelerations (ACC) were recorded as well as the Mechanomyography (MMG) of the biceps brachii, the brachioradialis and of the pectoralis major muscles using piezoelectric-sensors during the bilateral motor task at 60% of the maximal isometric contraction. The frequency, a specific power ratio, the amplitude variation and the slope of amplitudes were analysed. The results indicate that the oscillatory behaviour of motor output in PD patients without tremor deviates from controls: thereby, the 95%-confidence-intervals of power ratio and of amplitude variation of all signals are disjoint between PD and controls and show significant differences in group comparisons (power ratio: p = 0.000–0.004, r = 0.441–0.579; amplitude variation: p = 0.000–0.001, r = 0.37–0.67). The mean frequency shows a significant difference for ACC (p = 0.009, r = 0.43), but not for MMG. It remains open, whether this muscular output reflects changes of brain circuits and whether the results are reproducible and specific for PD.
In sports and movement sciences isometric muscle function is usually measured by pushing against a stable resistance. However, subjectively one can hold or push isometrically. Several investigations suggest a distinction of those forms. The aim of this study was to investigate whether these two forms of isometric muscle action can be distinguished by objective parameters in an interpersonal setting. 20 subjects were grouped in 10 same sex pairs, in which one partner should perform the pushing isometric muscle action (PIMA) and the other partner executed the holding isometric muscle action (HIMA). The partners had contact at the distal forearms via an interface, which included a strain gauge and an acceleration sensor. The mechanical oscillations of the triceps brachii (MMGtri) muscle, its tendon (MTGtri) and the abdominal muscle (MMGobl) were recorded by a piezoelectric-sensor-based measurement system. Each partner performed three 15s (80% MVIC) and two fatiguing trials (90% MVIC) during PIMA and HIMA, respectively. Parameters to compare PIMA and HIMA were the mean frequency, the normalized mean amplitude, the amplitude variation, the power in the frequency range of 8 to 15 Hz, a special power-frequency ratio and the number of task failures during HIMA or PIMA (partner who quit the task). A “HIMA failure” occurred in 85% of trials (p < 0.001). No significant differences between PIMA and HIMA were found for the mean frequency and normalized amplitude. The MMGobl showed significantly higher values of amplitude variation (15s: p = 0.013; fatiguing: p = 0.007) and of power-frequency-ratio (15s: p = 0.040; fatiguing: p = 0.002) during HIMA and a higher power in the range of 8 to 15 Hz during PIMA (15s: p = 0.001; fatiguing: p = 0.011). MMGtri and MTGtri showed no significant differences. Based on the findings it is suggested that a holding and a pushing isometric muscle action can be distinguished objectively, whereby a more complex neural control is assumed for HIMA.
In sports and movement sciences isometric muscle function is usually measured by pushing against a stable resistance. However, subjectively one can hold or push isometrically. Several investigations suggest a distinction of those forms. The aim of this study was to investigate whether these two forms of isometric muscle action can be distinguished by objective parameters in an interpersonal setting. 20 subjects were grouped in 10 same sex pairs, in which one partner should perform the pushing isometric muscle action (PIMA) and the other partner executed the holding isometric muscle action (HIMA). The partners had contact at the distal forearms via an interface, which included a strain gauge and an acceleration sensor. The mechanical oscillations of the triceps brachii (MMGtri) muscle, its tendon (MTGtri) and the abdominal muscle (MMGobl) were recorded by a piezoelectric-sensor-based measurement system. Each partner performed three 15s (80% MVIC) and two fatiguing trials (90% MVIC) during PIMA and HIMA, respectively. Parameters to compare PIMA and HIMA were the mean frequency, the normalized mean amplitude, the amplitude variation, the power in the frequency range of 8 to 15 Hz, a special power-frequency ratio and the number of task failures during HIMA or PIMA (partner who quit the task). A “HIMA failure” occurred in 85% of trials (p < 0.001). No significant differences between PIMA and HIMA were found for the mean frequency and normalized amplitude. The MMGobl showed significantly higher values of amplitude variation (15s: p = 0.013; fatiguing: p = 0.007) and of power-frequency-ratio (15s: p = 0.040; fatiguing: p = 0.002) during HIMA and a higher power in the range of 8 to 15 Hz during PIMA (15s: p = 0.001; fatiguing: p = 0.011). MMGtri and MTGtri showed no significant differences. Based on the findings it is suggested that a holding and a pushing isometric muscle action can be distinguished objectively, whereby a more complex neural control is assumed for HIMA.
The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects’ maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed.
The improvement of power is an objective in training of athletes. In order to detect effective methods of exercise, basic research is required regarding the mechanisms of muscular activity. The purpose of this study is to investigate whether or not a muscular pre-activation prior to an external impulse-like force impact has an effect on the maximal explosive eccentric Adaptive Force (xpAFeccmax). This power capability combines different probable power enhancing mechanisms. To measure the xpAFeccmax an innovative pneumatic device was used. During measuring, the subject tries to hold an isometric position as long as possible. In the moment in which the subjects’ maximal isometric holding strength is exceeded, it merges into eccentric muscle action. This process is very close to motions in sports, where an adaptation of the neuromuscular system is required, e.g., force impacts caused by uneven surfaces during skiing. For investigating the effect of pre-activation on the xpAFeccmax of the quadriceps femoris muscle, n = 20 subjects had to pass three different pre-activation levels in a randomized order (level 1: 0.4 bar, level 2: 0.8 bar, level 3: 1.2 bar). After adjusting the standardized pre-pressure by pushing against the interface, an impulse-like load impacted on the distal tibia of the subject. During this, the xpAFeccmax was detected. The maximal voluntary isometric contraction (MVIC) was also measured. The torque values of the xpAFeccmax were compared with regard to the pre-activation levels. The results show a significant positive relation between the pre-activation of the quadriceps femoris muscle and the xpAFeccmax (male: p = 0.000, η2= 0.683; female: p = 0.000, η2= 0.907). The average percentage increase of torque amounted +28.15 ± 25.4% between MVIC and xpAFeccmax with pre-pressure level 1, +12.09 ± 7.9% for the xpAFeccmax comparing pre-pressure levels 1 vs. 2 and +2.98 ± 4.2% comparing levels 2 and 3. A higher but not maximal muscular activation prior to a fast impacting eccentric load seems to produce an immediate increase of force outcome. Different possible physiological explanatory approaches and the use as a potential training method are discussed.
The regulation of oxygen and blood supply during isometric muscle actions is still unclear. Recently, two behavioral types of oxygen saturation (SvO2) and relative hemoglobin amount (rHb) in venous microvessels were described during a fatiguing holding isometric muscle action (HIMA) (type I: nearly parallel behavior of SvO2 and rHb; type II: partly inverse behavior). The study aimed to ascertain an explanation of these two regulative behaviors. Twelve subjects performed one fatiguing HIMA trial with each arm by weight holding at 60% of the maximal voluntary isometric contraction (MVIC) in a 90° elbow flexion. Six subjects additionally executed one fatiguing PIMA trial by pulling on an immovable resistance with 60% of the MVIC with each side and same position. Both regulative types mentioned were found during HIMA (I: n = 7, II: n = 17) and PIMA (I: n = 3, II: n = 9). During the fatiguing measurements, rHb decreased initially and started to increase in type II at an average SvO2-level of 58.75 ± 2.14%. In type I, SvO2 never reached that specific value during loading. This might indicate the existence of a threshold around 59% which seems to trigger the increase in rHb and could explain the two behavioral types. An approach is discussed to meet the apparent incompatibility of an increased capillary blood filling (rHb) despite high intramuscular pressures which were found by other research groups during isometric muscle actions.
The regulation of oxygen and blood supply during isometric muscle actions is still unclear. Recently, two behavioral types of oxygen saturation (SvO(2)) and relative hemoglobin amount (rHb) in venous microvessels were described during a fatiguing holding isometric muscle action (HIMA) (type I: nearly parallel behavior of SvO(2) and rHb; type II: partly inverse behavior). The study aimed to ascertain an explanation of these two regulative behaviors. Twelve subjects performed one fatiguing HIMA trial with each arm by weight holding at 60% of the maximal voluntary isometric contraction (MVIC) in a 90 & DEG; elbow flexion. Six subjects additionally executed one fatiguing PIMA trial by pulling on an immovable resistance with 60% of the MVIC with each side and same position. Both regulative types mentioned were found during HIMA (I: n = 7, II: n = 17) and PIMA (I: n = 3, II: n = 9). During the fatiguing measurements, rHb decreased initially and started to increase in type II at an average SvO(2)-level of 58.75 & PLUSMN; 2.14%. In type I, SvO(2) never reached that specific value during loading. This might indicate the existence of a threshold around 59% which seems to trigger the increase in rHb and could explain the two behavioral types. An approach is discussed to meet the apparent incompatibility of an increased capillary blood filling (rHb) despite high intramuscular pressures which were found by other research groups during isometric muscle actions.
The regulation of oxygen and blood supply during isometric muscle actions is still unclear. Recently, two behavioral types of oxygen saturation (SvO2) and relative hemoglobin amount (rHb) in venous microvessels were described during a fatiguing holding isometric muscle action (HIMA) (type I: nearly parallel behavior of SvO2 and rHb; type II: partly inverse behavior). The study aimed to ascertain an explanation of these two regulative behaviors. Twelve subjects performed one fatiguing HIMA trial with each arm by weight holding at 60% of the maximal voluntary isometric contraction (MVIC) in a 90° elbow flexion. Six subjects additionally executed one fatiguing PIMA trial by pulling on an immovable resistance with 60% of the MVIC with each side and same position. Both regulative types mentioned were found during HIMA (I: n = 7, II: n = 17) and PIMA (I: n = 3, II: n = 9). During the fatiguing measurements, rHb decreased initially and started to increase in type II at an average SvO2-level of 58.75 ± 2.14%. In type I, SvO2 never reached that specific value during loading. This might indicate the existence of a threshold around 59% which seems to trigger the increase in rHb and could explain the two behavioral types. An approach is discussed to meet the apparent incompatibility of an increased capillary blood filling (rHb) despite high intramuscular pressures which were found by other research groups during isometric muscle actions.
Background
Isometric muscle actions can be performed either by initiating the action, e.g., pulling on an immovable resistance (PIMA), or by reacting to an external load, e.g., holding a weight (HIMA). In the present study, it was mainly examined if these modalities could be differentiated by oxygenation variables as well as by time to task failure (TTF). Furthermore, it was analyzed if variables are changed by intermittent voluntary muscle twitches during weight holding (Twitch). It was assumed that twitches during a weight holding task change the character of the isometric muscle action from reacting (≙ HIMA) to acting (≙ PIMA).
Methods
Twelve subjects (two drop outs) randomly performed two tasks (HIMA vs. PIMA or HIMA vs. Twitch, n = 5 each) with the elbow flexors at 60% of maximal torque maintained until muscle failure with each arm. Local capillary venous oxygen saturation (SvO2) and relative hemoglobin amount (rHb) were measured by light spectrometry.
Results
Within subjects, no significant differences were found between tasks regarding the behavior of SvO2 and rHb, the slope and extent of deoxygenation (max. SvO2 decrease), SvO2 level at global rHb minimum, and time to SvO2 steady states. The TTF was significantly longer during Twitch and PIMA (incl. Twitch) compared to HIMA (p = 0.043 and 0.047, respectively). There was no substantial correlation between TTF and maximal deoxygenation independently of the task (r = − 0.13).
Conclusions
HIMA and PIMA seem to have a similar microvascular oxygen and blood supply. The supply might be sufficient, which is expressed by homeostatic steady states of SvO2 in all trials and increases in rHb in most of the trials. Intermittent voluntary muscle twitches might not serve as a further support but extend the TTF. A changed neuromuscular control is discussed as possible explanation.
Background
Isometric muscle actions can be performed either by initiating the action, e.g., pulling on an immovable resistance (PIMA), or by reacting to an external load, e.g., holding a weight (HIMA). In the present study, it was mainly examined if these modalities could be differentiated by oxygenation variables as well as by time to task failure (TTF). Furthermore, it was analyzed if variables are changed by intermittent voluntary muscle twitches during weight holding (Twitch). It was assumed that twitches during a weight holding task change the character of the isometric muscle action from reacting (≙ HIMA) to acting (≙ PIMA).
Methods
Twelve subjects (two drop outs) randomly performed two tasks (HIMA vs. PIMA or HIMA vs. Twitch, n = 5 each) with the elbow flexors at 60% of maximal torque maintained until muscle failure with each arm. Local capillary venous oxygen saturation (SvO2) and relative hemoglobin amount (rHb) were measured by light spectrometry.
Results
Within subjects, no significant differences were found between tasks regarding the behavior of SvO2 and rHb, the slope and extent of deoxygenation (max. SvO2 decrease), SvO2 level at global rHb minimum, and time to SvO2 steady states. The TTF was significantly longer during Twitch and PIMA (incl. Twitch) compared to HIMA (p = 0.043 and 0.047, respectively). There was no substantial correlation between TTF and maximal deoxygenation independently of the task (r = − 0.13).
Conclusions
HIMA and PIMA seem to have a similar microvascular oxygen and blood supply. The supply might be sufficient, which is expressed by homeostatic steady states of SvO2 in all trials and increases in rHb in most of the trials. Intermittent voluntary muscle twitches might not serve as a further support but extend the TTF. A changed neuromuscular control is discussed as possible explanation.
The mechanotendography (MTG) is a method for analyzing the mechanical oscillations of tendons during muscular actions. The aim of this investigation was to evaluate the technical reliability of a piezo-based measurement system used for MTG. The reliability measurements were performed by using audio samples played by a subwoofer. The thereby generated pressure waves were recorded by a piezo-based measurement system. An audio of 40 Hz sine oscillations and four different formerly in vivo recorded MTG-signals were converted into audio files and were used as test signals. Five trials with each audio were performed and one audio was used for repetition trials on another day. The signals’ correlation was estimated by Spearman (MCC) and intraclass correlation coefficients (ICC(3,1)), Cronbach’s alpha (CA) and by mean distances (MD). All parameters were compared between repetition and randomized matched signals. The repetition trials show high correlations (MCC: 0.86 ± 0.13, ICC: 0.89 ± 0.12, CA: 0.98 ± 0.03), low MD (0.03 ± 0.03V) and differ significantly from the randomized matched signals (MCC: 0.15 ± 0.10, ICC: 0.17 ± 0.09, CA: 0.37 ± 0.16, MD: 0.19 ± 0.01V) (p = 0.001 – 0.043). This speaks for an excellent reliability of the measurement system. Presuming the skin above superficial tendons oscillates adequately, we estimate this tool as valid for the application in musculoskeletal system.
The present study focuses on an innovative approach in measuring the mechanical oscillations of pre-loaded Achilles tendon by using Mechanotendography (MTG) during application of a short yet powerful mechanical pressure impact. This was applied on the forefoot from the plantar side in direction of dorsiflexion, while the subject stood on the ball of the forefoot on one leg. Participants with Achilles tendinopathy (AT; n = 10) were compared to healthy controls (Con; n = 10). Five trials were performed on each side of the body. For evaluation, two intervals after the impulse began (0-100ms; 30-100ms) were cut from the MTG and pressure raw signals. The intrapersonal variability between the five trials in both intervals were evaluated using the arithmetic mean and coefficient of variation of the mean correlation (Spearman rank correlation) and the normalized averaged mean distances, respectively. The AT-group showed a significantly reduced variability in MTG compared to the Con-group (from p = 0.006 to p = 0.028 for different parameters). The 95% confidence intervals (CI) of MTG results were disjoint, whereas the 95% CIs of the pressure signals were similar (p = 0.192 to p = 0.601). We suggest from this work that the variability of mechanical tendon oscillations could be an indicative parameter of an altered Achilles tendon functionality.