Refine
Year of publication
- 2009 (129) (remove)
Document Type
- Article (100)
- Doctoral Thesis (24)
- Postprint (4)
- Habilitation Thesis (1)
Keywords
- Leguminosae (2)
- (S)-Elatadihydrochalcone (1)
- (S)-Lupinifolin 4´-methyl ether (1)
- Azobenzene (1)
- Biokonjugate (1)
- Cellulose (1)
- Characterisation (1)
- Charakterisierung (1)
- Derris trifoliata (1)
- Design (1)
Institute
- Institut für Chemie (129) (remove)
Radical additions to glycals : synthesis and transformations of 2-functionalized carbohydrates
(2009)
Molecular modeling calculations using DFT at the B3LYP/6-31G(d,p) level of theory have been performed on diastereomeric complexes formed between chiral carboxylate anions and chiral urea receptors, a combination previously demonstrated to enable enantiodifferentiation by electrochemical sensing. The calculations correctly predicted the stability order of the enantiomers in acetonitrile solution when the distinction between the enantiomers was above the declared threshold reliability value of 1 kcal mol;1 for computations at this level of theory. Thus, the calculations can not only be applied to predict the likely success of undertakings using the analytical method, it can also, provided ;E is sufficient, potentially be used to determine the absolute configuration of chiral analytes with at least the racemate in hand. The previously successful enantiodifferentiations of various amino acids and alcohols using chiral ion mobility spectroscopy (CIMS) with (S)-2-butanol as the chiral selector were also evaluated by DFT calculations. The calculations again correctly predicted the stability order of the enantiomers when the calculated ;E was above the threshold value though cases not providing a value for ;E above the threshold value was problematic for this system. Attempts to address this shortcoming included an expanded conformational evaluation, a broader analytical approach, and an extended basis set.
One of the main issues with the use of nickel titanium alloy (NiTi) implants in cardiovascular implants (stents) is that these devices must be of very high quality in order to avoid subsequent operations due to failing stents. For small stents with diameters below ca. 2 mm, however, stent characterization is not straightforward. One of the main problems is that there are virtually no methods to characterize the interior of the NiTi tubes used for fabrication of these tiny stents. The current paper reports on a robust hybrid actuator for the characterization of NiTi tubes prior to stent fabrication. The method is based on a polymer/hydrogel/magnetic nanoparticle hybrid material and allows for the determination of the inner diameter at virtually all places in the raw NiTi tubes. Knowledge of the inner structure of the raw NiTi tubes is crucial to avoid regions that are not hollow or regions that are likely to fail due to defects inside the raw tube. The actuator enables close contact of a magnetic polymer film with the inner NiTi tube surface. The magnetic signal can be detected from outside and be used for a direct mapping of the tube interior. As a result, it is possible to detect critical regions prior to expensive and slow stent fabrication processes.