Refine
Year of publication
Document Type
- Article (12)
- Doctoral Thesis (1)
Language
- English (13)
Is part of the Bibliography
- yes (13) (remove)
Keywords
- FRET (3)
- quantum dots (2)
- Base pairing (1)
- Diagnostics (1)
- Fluorescence spectroscopy (1)
- Imaging (1)
- Lanthanide (1)
- Lanthanides (1)
- Naphthyridine receptor (1)
- Nucleotide nanosensor (1)
Institute
The determination of low-molecular weight substances (haptens) is demonstrated with a homogeneous time-resolved immunoassay using antibody-induced luminescence quenching. Our novel assay technology uses the newly developed monoclonal antibody (G24-BA9) to quench the luminescence of europium trisbipyridine (EuTBP). We performed a competitive biotin immunoassay including an EuTBP-biotin conjugate, the anti-EuTBP antibody G24-BA9 and streptavidin as assay components. Steric hindrance allows only the binding of either G24-BA9 (to the EuTBP moiety) or streptavidin (to the biotin moiety) to the EuTBP-biotin conjugate. Addition of the analyte biotin resulted in the binding of streptavidin to biotin and a concomitant preferred binding of G24-BA9 to EuTBP-biotin. Since G24-BA9 quenches the luminescence of EuTBP within the conjugate, the luminescence signal could be used to indicate and quantify the presence of free biotin in the system. All experiments were carried out in solution in the presence of 5% serum demonstrating the possibility of using our novel assay for a very fast determination of low molecular weight substances in biological fluids.
Using a regioselective strategy for nucleophilic aromatic substitution on polyfluoropyridines, a nonacoordinating precursor was designed that is adequately suited for complexation of lanthanide cations. Further functionalizations afforded numerous applications for near-IR emission, two-photon absorption spectroscopy, or the formation of luminescent gels.
Nanobioconjugates have been synthesized using cadmium selenide quantum dots (QDs), europium complexes (EuCs), and biotin. In those conjugates, long-lived photoluminescence (PL) is provided by the europium complexes, which efficiently transfer energy via Forster resonance energy transfer (FRET) to the QDs in close spatial proximity. As a result, the conjugates have a PL emission spectrum characteristic for QDs combined with the long PL decay time characteristic for EuCs. The nanobioconjugates synthesis strategy and photo-physical properties are described as well as their performance in a time-resolved streptavidin-biotin PL assay. In order to prepare the QD-EuC-biotin conjugates, first an amphiphilic polymer has been functionalized with the EuC and biotin. Then, the polymer has been brought onto the surface of the QDs (either QD655 or QD705) to provide functionality and to make the QDs water dispersible. Due to a short distance between EuC and QD, an efficient FRET can be observed. Additionally, the QD-EuC-biotin conjugates' functionality has been demonstrated in a PL assay yielding good signal discrimination, both from autofluorescence and directly excited QDs. These newly designed QD-EuC-biotin conjugates expand the class of highly sensitive tools for bioanalytical optical detection methods for diagnostic and imaging applications. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)
In this microreview we describe the principle of Forster resonance energy transfer (FRET) occurring between closely spaced energy-donor and -acceptor molecules. The theoretical treatment is depicted in relation with the data extractable from spectroscopic measurements. We present the specific case of semiconductor nanocrystals (or quantum dots QDs) as energy donors in FRET experiments and a particular emphasis is put on the specific advantages of these fluorophores with regard to both their exceptional photophysical properties and their nanoscopic morphology. In a following section, the special attributes of luminescent lanthanide complexes (LLCs) are outlined with illustrations of properties such as their characteristic emission spectra, long-lived luminescence, and large "Stokes shift". Finally, the successful combination of LLCs and QDs in FRET experiments is demonstrated, showing the unrivaled benefits of this singular marriage, opening doors for energy transfer at very large distances and excellent sensitivity of detection within the frame of time-resolved fluoroimmunoassays. ((C) Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2008).
Förster Resonance Energy Transfer (FRET) plays an important role for biochemical applications such as DNA sequencing, intracellular protein-protein interactions, molecular binding studies, in vitro diagnostics and many others. For qualitative and quantitative analysis, FRET systems are usually assembled through molecular recognition of biomolecules conjugated with donor and acceptor luminophores. Lanthanide (Ln) complexes, as well as semiconductor quantum dot nanocrystals (QD), possess unique photophysical properties that make them especially suitable for applied FRET. In this work the possibility of using QD as very efficient FRET acceptors in combination with Ln complexes as donors in biochemical systems is demonstrated. The necessary theoretical and practical background of FRET, Ln complexes, QD and the applied biochemical models is outlined. In addition, scientific as well as commercial applications are presented. FRET can be used to measure structural changes or dynamics at distances ranging from approximately 1 to 10 nm. The very strong and well characterized binding process between streptavidin (Strep) and biotin (Biot) is used as a biomolecular model system. A FRET system is established by Strep conjugation with the Ln complexes and QD biotinylation. Three Ln complexes (one with Tb3+ and two with Eu3+ as central ion) are used as FRET donors. Besides the QD two further acceptors, the luminescent crosslinked protein allophycocyanin (APC) and a commercial fluorescence dye (DY633), are investigated for direct comparison. FRET is demonstrated for all donor-acceptor pairs by acceptor emission sensitization and a more than 1000-fold increase of the luminescence decay time in the case of QD reaching the hundred microsecond regime. Detailed photophysical characterization of donors and acceptors permits analysis of the bioconjugates and calculation of the FRET parameters. Extremely large Förster radii of more than 100 Å are achieved for QD as acceptors, considerably larger than for APC and DY633 (ca. 80 and 60 Å). Special attention is paid to interactions with different additives in aqueous solutions, namely borate buffer, bovine serum albumin (BSA), sodium azide and potassium fluoride (KF). A more than 10-fold limit of detection (LOD) decrease compared to the extensively characterized and frequently used donor-acceptor pair of Europium tris(bipyridine) (Eu-TBP) and APC is demonstrated for the FRET system, consisting of the Tb complex and QD. A sub-picomolar LOD for QD is achieved with this system in azide free borate buffer (pH 8.3) containing 2 % BSA and 0.5 M KF. In order to transfer the Strep-Biot model system to a real-life in vitro diagnostic application, two kinds of imunnoassays are investigated using human chorionic gonadotropin (HCG) as analyte. HCG itself, as well as two monoclonal anti-HCG mouse-IgG (immunoglobulin G) antibodies are labeled with the Tb complex and QD, respectively. Although no sufficient evidence for FRET can be found for a sandwich assay, FRET becomes obvious in a direct HCG-IgG assay showing the feasibility of using the Ln-QD donor-acceptor pair as highly sensitive analytical tool for in vitro diagnostics.
Multiplexed diagnostics and spectroscopic ruler applications with terbium to quantum dots FRET
(2008)
Time- and color-resolved detection of Foerster resonance energy transfer (FRET) from luminescent terbium complexes to different semiconductor quantum dots results in a fivefold multiplexed bioassay with sub-picomolar detection limits for all five bioanalytes (see picture). The detection of up to five biomarkers occurs with a sensitivity that is 40-240-fold higher than one of the best-established single-analyte reference assays.
Applications based on Forster resonance energy transfer (FRET) play an important role for the determination of concentrations and distances within nanometer-scale systems in vitro and in vivo in many fields of biotechnology. Semiconductor nanocrystals (Quantum dots - QDs) possess ideal properties for their application as FRET acceptors when the donors have long excited state lifetimes and when direct excitation of QDs can be efficiently suppressed. Therefore, luminescent terbium complexes (LTCs) with excited state lifetimes of more than 2 ms are ideal FRET donor candidates for QD-acceptors. This chapter will give a short overview of theoretical and practical background of FRET, QDs and LTCs, and present some recent applications of LTC-QD FRET pairs for multiplexed ultra-sensitive in vitro diagnostics and nanometer-resolution molecular distance measurements.
Novel fluorescent nanosensors, based on a naphthyridine receptor, have been developed for the detection of guanosine nucleotides, and both their sensitivity and selectivity to various nucleotides were evaluated. The nanosensors were constructed from polystyrene nanoparticles functionalized by (N-(7-((3-aminophenyl) ethynyl)-1,8-naphthyridin- 2-yl) acetamide) via carbodiimide ester activation. We show that this naphthyridine nanosensor binds guanosine nucleotides preferentially over adenine, cytosine, and thymidine nucleotides. Upon interaction with nucleotides, the fluorescence of the nanosensor is gradually quenched yielding Stern-Volmer constants in the range of 2.1 to 35.9mM(-1). For all the studied quenchers, limits of detection (LOD) and tolerance levels for the nanosensors were also determined. The lowest (3 sigma) LOD was found for guanosine 3',5'-cyclic monophosphate (cGMP) and it was as low as 150 ng/ml. In addition, we demonstrated that the spatial arrangement of bound analytes on the nanosensors' surfaces is what is responsible for their selectivity to different guanosine nucleotides. We found a correlation between the changes of the fluorescence signal and the number of phosphate groups of a nucleotide. Results of molecular modeling and zeta-potential measurements confirm that the arrangement of analytes on the surface provides for the selectivity of the nanosensors. These fluorescent nanosensors have the potential to be applied in multi-analyte, array-based detection platforms, as well as in multiplexed microfluidic systems.