Refine
Year of publication
Document Type
- Article (11)
- Doctoral Thesis (1)
- Postprint (1)
Is part of the Bibliography
- yes (13) (remove)
Keywords
- Anisotropy (1)
- Energy-transfer probe (1)
- Exciplex (1)
- Fluorescence (1)
- Fluorescence Quenching Immunoassay (1)
- Fluorescence quenching immunoassay (1)
- Homogeneous immunoassay (1)
- Homoger Immunoassay (1)
- Hybridoma (1)
- MALDI-TOF-MS (1)
Immunochemical analytical methods are very successful in clinical diagnostics and are nowadays also emerging in the control of food as well as monitoring of environmental issues. Among the different immunoassays, luminescence based formats are characterized by their outstanding sensitivity making this format especially attractive for future applications. The need for multiparameter detection capabilities calls for a tool box of dye labels in order to transduce the biochemical reaction into an optically detectable signal. Here, in a multiparameter approach each analyte may be detected by a different dye with a unique emission color (covering the blue to red spectral range) or a unique luminescence decay kinetics. In the case of a competitive immunoassay format for each of the different dye labels an individual antibody would be needed. In the present paper a slightly modified approach is presented using a 7-aminocoumarin unit as the basic antigen against which highly specific antibodies were generated. Leaving the epitope region in the dyes unchanged but introducing a side group in positon 3 of the coumarin system allowed us to tune the optical properties of the coumarin dyes without the necessity of new antibody generation. Upon modification of the parent coumarin unit the full spectral range from blue to deep red was accessed. In the manuscript the photophysical characterization of the coumarin derivatives and their corresponding immunocomplexes with two highly specific antibodies is presented. The coumarin dyes and their immunocomplexes were characterized by steady-state and time-resolved absorption as well as emission spectroscopy. Moreover, fluorescence depolarization measurements were carried out to complement the data stressing the different binding modes of the two antibodies. The binding modes were evaluated using the photophysics of 7-aminocoumarins and how it was affected in the respective immunocomplexes, namely, the formation of the intramolecular charge transfer (ICT) as well as the twisted intramolecular charge transfer (TICT). In contrast to other antibody-dye pairs reported a distinct fluorescence enhancement upon formation of the antibody-dye complex up to a factor of SO was found. Because of the easy emission color tuning by tailoring the coumarin substitution for the antigen binding in nonrelevant position 3 of the parent molecule, a dye tool box is on hand which can be used in the construction of competitive multiparameter fluorescence enhancement immunoassays (FenIA).
Bright or dark immune complexes of anti-TAMRA antibodies for adapted fluorescence-based bioanalysis
(2015)
Fluorescence labels, for example fluorescein or rhodamin derivatives, are widely used in bioanalysis applications including lateral-flow assays, PCR, and fluorescence microscopy. Depending on the layout of the particular application, fluorescence quenching or enhancement may be desired as the detection principle. Especially for multiplexed applications or high-brightness requirements, a tunable fluorescence probe can be beneficial. The alterations in the photophysics of rhodamine derivatives upon binding to two different anti-TAMRA antibodies were investigated by absorption and fluorescence-spectroscopy techniques, especially determining the fluorescence decay time and steady-state and time-resolved fluorescence anisotropy. Two monoclonal anti-TAMRA antibodies were generated by the hybridoma technique. Although surface-plasmon-resonance measurements clearly proved the high affinity of both antibodies towards 5-TAMRA, the observed effects on the fluorescence of rhodamine derivatives were very different. Depending on the anti-TAMRA antibody either a strong fluorescence quenching (G71-DC7) or a distinct fluorescence enhancement (G71-BE11) upon formation of the immune complex was observed. Additional rhodamine derivatives were used to gain further information on the binding interaction. The data reveal that such haptens as 5-TAMRA could generate different paratopes with equal binding affinities but different binding interactions, which provide the opportunity to adapt bioanalysis methods including immunoassays for optimized detection principles for the same hapten depending on the specific requirements.
Different signal amplification strategies to improve the detection sensitivity of immunoassays have been applied which utilize enzymatic reactions, nanomaterials, or liposomes. The latter are very attractive materials for signal amplification because liposomes can be loaded with a large amount of signaling molecules, leading to a high sensitivity. In addition, liposomes can be used as a cell-like "bioscaffold" to directly test recognition schemes aiming at cell-related processes. This study demonstrates an easy and fast approach to link the novel hydrophobic optical probe based on [1,3]dioxolo[4,5-f]-[1,3]benzodioxole (DBD dye mm239) with tunable optical properties to hydrophilic recognition elements (e.g., antibodies) using liposomes for signal amplification and as carrier of the hydrophobic dye. The fluorescence properties of mm239 (e.g., long fluorescence lifetime, large Stokes shift, high photostability, and high quantum yield), its high hydrophobicity for efficient anchoring in liposomes, and a maleimide bioreactive group were applied in a unique combination to build a concept for the coupling of antibodies or other protein markers to liposomes (coupling to membranes can be envisaged). The concept further allowed us to avoid multiple dye labeling of the antibody. Here, anti-TAMRA-antibody (DC7-Ab) was attached to the liposomes. In proof-of-concept, steady-state as well as time-resolved fluorescence measurements (e.g., fluorescence depolarization) in combination with single molecule detection (fluorescence correlation spectroscopy, FCS) were used to analyze the binding interaction between DC7-Ab and liposomes as well as the binding of the antigen rhodamine 6G (R6G) to the antibody. Here, the Forster resonance energy transfer (FRET) between mm239 and R6G was monitored. In addition to ensemble FRET data, single-molecule FRET (PIE-FRET) experiments using pulsed interleaved excitation were used to characterize in detail the binding on a single-molecule level to avoid averaging out effects.
A water soluble fluorescent polymer as a dual colour sensor for temperature and a specific protein
(2013)
We present two thermoresponsive water soluble copolymers prepared via free radical statistical copolymerization of N-isopropylacrylamide (NIPAm) and of oligo(ethylene glycol) methacrylates (OEGMAs), respectively, with a solvatochromic 7-(diethylamino)-3-carboxy-coumarin (DEAC)-functionalized monomer. In aqueous solutions, the NIPAm-based copolymer exhibits characteristic changes in its fluorescence profile in response to a change in solution temperature as well as to the presence of a specific protein, namely an anti-DEAC antibody. This polymer emits only weakly at low temperatures, but exhibits a marked fluorescence enhancement accompanied by a change in its emission colour when heated above its cloud point. Such drastic changes in the fluorescence and absorbance spectra are observed also upon injection of the anti-DEAC antibody, attributed to the specific binding of the antibody to DEAC moieties. Importantly, protein binding occurs exclusively when the polymer is in the well hydrated state below the cloud point, enabling a temperature control on the molecular recognition event. On the other hand, heating of the polymer-antibody complexes releases a fraction of the bound antibody. In the presence of the DEAC-functionalized monomer in this mixture, the released antibody competitively binds to the monomer and the antibody-free chains of the polymer undergo a more effective collapse and inter-aggregation. In contrast, the emission properties of the OEGMA-based analogous copolymer are rather insensitive to the thermally induced phase transition or to antibody binding. These opposite behaviours underline the need for a carefully tailored molecular design of responsive polymers aimed at specific applications, such as biosensing.
A water soluble fluorescent polymer as a dual colour sensor for temperature and a specific protein
(2013)
We present two thermoresponsive water soluble copolymers prepared via free radical statistical copolymerization of N-isopropylacrylamide (NIPAm) and of oligo(ethylene glycol) methacrylates (OEGMAs), respectively, with a solvatochromic 7-(diethylamino)-3-carboxy-coumarin (DEAC)- functionalized monomer. In aqueous solutions, the NIPAm-based copolymer exhibits characteristic changes in its fluorescence profile in response to a change in solution temperature as well as to the presence of a specific protein, namely an anti-DEAC antibody. This polymer emits only weakly at low temperatures, but exhibits a marked fluorescence enhancement accompanied by a change in its emission colour when heated above its cloud point. Such drastic changes in the fluorescence and absorbance spectra are observed also upon injection of the anti-DEAC antibody, attributed to the specific binding of the antibody to DEAC moieties. Importantly, protein binding occurs exclusively when the polymer is in the well hydrated state below the cloud point, enabling a temperature control on the molecular recognition event. On the other hand, heating of the polymer–antibody complexes releases a fraction of the bound antibody. In the presence of the DEAC-functionalized monomer in this mixture, the released antibody competitively binds to the monomer and the antibody-free chains of the polymer undergo a more effective collapse and inter-aggregation. In contrast, the emission properties of the OEGMA-based analogous copolymer are rather insensitive to the thermally induced phase transition or to antibody binding. These opposite behaviours underline the need for a carefully tailored molecular design of responsive polymers aimed at specific applications, such as biosensing.
The large scale production of a monoclonal anti-progesterone antibody in serum free medium followed by affinity chromatography on protein G lead to a contamination of the antibody sample with a protein of about 14 kDa. This protein was identified by mass spectrometry as secretory leukocyte protease inhibitor (SLPI). This SLPI contamination lead to a failure of the fiber-optic based competitive fluorescence assay to detect progesterone in milk. Purification of the monoclonal antibody using protein A columns circumvented this problem.
A recombinant single chain antibody fragment (designated scDE1) of the murine monoclonal anti-fluorescein antibody B13-DE1 was generated using the original hybridoma cells as source for the variable antibody heavy and light chain (VH and VL) genes. After cloning the variable genes into a phage vector a functional antibody fragment was selected by phage display panning. Recombinant antibody could be expressed as phage antibody and as soluble single chain antibody in Escherichia coli. High yield of scDE1 could also be detected in bacterial culture supernatant. The scDE1 showed the same binding specificity as the parental monoclonal antibody, i.e. it bound fluorescein, fluorescein derivatives and a fluorescein peptide mimotope. Surface plasmon resonance revealed a K(D) of 19 nM for the scDE1 compared to 0.7 nM for the monoclonal antibody. The isolated soluble scDE1 could easily be conjugated to horseradish peroxidase which allowed the use of the conjugate as universal indicator for the detection of fluorescein-labelled proteins in different immunoassays. Detection of hCG in urine was performed as a model system using scDE1. In addition to E. coli the scFv genes could also be transferred and expressed in eukaryotic cells. Finally, we generated HEK293 cells expressing the scDE1 at the cell surface.
Homogene Immunoassays sind immunologische Testverfahren, bei deren Durchführung vollständig auf Separations- und Waschschritte verzichtet werden kann. Der Substrate Channeling Immunoassay beruht auf der Weitergabe eines Substrates in einem immunologischen Komplex aus zwei Enzymen. Das Produkt des ersten Enzyms dient dem zweiten Enzym als Substrat zur Generierung eines photometrisch nachweisbaren Produktes. Voraussetzung für diese Weitergabe ist die enge räumliche Nähe beider Enzyme. Diese Nähe wird durch eine Bindung zwischen Analyt und anti-Analyt Antikörper vermittelt. Ein solcher Substrate Channeling Immunoassay wurde unter Verwendung der Enzyme Glucoseoxidase und Peroxidase aufgebaut. Das so etablierte System war funktionstüchtig, jedoch blieb seine Sensitivität hinter der normaler, heterogener Immunoassays zurück. Die Grundlage eines Fluorescence Quenching Immunoassays ist der gegenseitige Ausschluß zweier Antikörper bei der Bindung eines Dihapten-Konjugates. Das Konjugat besteht dabei aus dem Analyten und einem Fluorophor. Die beiden um die Konjugatbindung konkurrierenden Antikörper sind ein anti-Analyt Antikörper und ein anti-Fluorophor Antikörper, der zudem über die Eigenschaft verfügt, bei Bindung des Fluorophors dessen Fluoreszenz zu löschen. Externe Gaben des freien Analyten verschieben das eingestellte Gleichgewicht in Richtung Fluorophor-Bindung und damit Fluoreszenz-Löschung. Die Änderung der Fluoreszenz ist direkt an die Konzentration des freien Analyten gekoppelt und dient zu deren Bestimmung. Ein solcher Fluorescence Quenching Immunoassays wurde für die Konzentrationsbestimmung des Herbizides Diuron etabliert. Die erreichten Sensitivitäten erlauben die praktische, immundiagnostische Anwendung des Systems. Ein Dihapten-Konjugat wurde ebenfalls zum Aufbau eines Verfahrens zur Selektion Antikörper produzierender Zellen eingesetzt. Die Selektion der Antikörper produzierenden Zellen erfolgt unter Verwendung eines Toxinkonjugates. Dieses Konjugat besteht aus einem Liganden und einem Toxin. Die Antikörperbindung des Liganden behindert sterisch die Wechselwirkung der Toxinkomponente im Konjugat mit deren Zielstruktur in oder auf der Zelle. Nur Zellen die einen geeigneten Antikörper sezernieren, überleben die Selektion und reichern sich in der Kultur an. Das Selektionsverfahren wurde erfolgreich für die Selektion von E.coli Zellen eingesetzt, die einen rekombinanten, Fluorescein bindenden Antikörper produzierten. Das hierfür synthetisierte Toxinkonjugat bestand aus Fluorescein (Ligand) und Ampicillin (Toxinkomponente). Eine Ablösung der bisher für diese Aufgabe gebräuchlichen, außerordentlich kostenintensiven, Screening Methoden wird damit möglich.
The determination of low-molecular weight substances (haptens) is demonstrated with a homogeneous time-resolved immunoassay using antibody-induced luminescence quenching. Our novel assay technology uses the newly developed monoclonal antibody (G24-BA9) to quench the luminescence of europium trisbipyridine (EuTBP). We performed a competitive biotin immunoassay including an EuTBP-biotin conjugate, the anti-EuTBP antibody G24-BA9 and streptavidin as assay components. Steric hindrance allows only the binding of either G24-BA9 (to the EuTBP moiety) or streptavidin (to the biotin moiety) to the EuTBP-biotin conjugate. Addition of the analyte biotin resulted in the binding of streptavidin to biotin and a concomitant preferred binding of G24-BA9 to EuTBP-biotin. Since G24-BA9 quenches the luminescence of EuTBP within the conjugate, the luminescence signal could be used to indicate and quantify the presence of free biotin in the system. All experiments were carried out in solution in the presence of 5% serum demonstrating the possibility of using our novel assay for a very fast determination of low molecular weight substances in biological fluids.
A competitive immunoassay to detect a hapten using an enzyme-labelled peptide mimotope as tracer
(2002)
Mimotope peptides-peptides which mimic the binding of a hapten to its corresponding monoclonal antibody-were conjugated to peroxidase and used in competitive immunoassay. The established immunoassay was used to quantitatively determine the concentration of hapten. As model system in all the experiments described here, we used the binding of the monoclonal antibody B13-DE1 to fluorescein and the corresponding peptide mimotope.