Refine
Has Fulltext
- no (27)
Year of publication
Document Type
- Other (27) (remove)
Language
- English (27) (remove)
Is part of the Bibliography
- yes (27)
Keywords
- Monte-Carlo simulations (1)
- Near infrared (1)
- OH suppression (1)
- PHEMA (1)
- Photon Density Wave Spectroscopy (1)
- SAW impedance sensor (1)
- Time-resolved crystallography (1)
- algae cultivation (1)
- astrophotonics (1)
- crystallography (1)
Institute
- Institut für Chemie (27) (remove)
Stable covalently photo-cross-linked porous poly(ionic liquid) membrane with gradient pore size
(2018)
Porous polyelectrolyte membranes stable in a highly ionic environment are obtained by covalent crosslinking of an imidazolium-based poly(ionic liquid). The crosslinking reaction involves the UV light-induced thiol-ene (click) chemistry, and the phase separation, occurring during the crosslinking step, generates a fully interconnected porous structure in the membrane. The porosity is on the order of the micrometer scale and the membrane shows a gradient of pore size across the membrane cross-section. The membrane can separate polystyrene latex particles of different size and undergoes actuation in contact with acetone due to the asymmetric porous structure.
Surface acoustic wave (SAW) devices are well-known for gravimetric sensor applications. In biosensing applications, chemical-and biochemically evoked adsorption processes at surfaces are detected in liquid environments using delay-line or resonator sensor configurations, preferably in combination with appropriate microfluidic devices. In this paper, a novel SAW-based impedance sensor type is introduced which uses only one interdigital electrode transducer (IDT) simultaneously as SAW generator and sensor element. It is shown that the amplitude of the reflected S-11 signal directly depends on the input impedance of the SAW device. The input impedance is strongly influenced by mass adsorption which causes a characteristic and measurable impedance mismatch.
This paper focuses on the characterization and use of polymer-modified phosphatidylcholine (PC)/sodium dodecyl sulfate (SDS)-based inverse microemulsions as a template phase for BaSO4 nanoparticle formation. The area of the optically clear inverse microemulsion phase in the isooctane/hexanol/water/PC/SDS system is not significantly changed by adding polyelectrolytes, i.e., poly(diallyldimethylammonium chloride) (PDADMAC), or amphoteric copolymers of diallyldimethylammonium chloride and maleamid acid to the SDS-modified inverse microemulsion. Shear experiments show non- Newtonian flow behavior and oscillation experiments show a frequency-dependent viscosity increase (dilatant behavior) of the microemulsions. Small amounts of bulk water were identified by means of differential scanning calorimetry. One can conclude that the macromolecules are incorporated into the individual droplets, and polymer-filled microemulsions are formed. The polymer-filled microemulsions were used as a template phase for the synthesis of BaSO4 nanoparticles. After solvent evaporation the nanoparticles were redispersed in water and isooctane, respectively. The polymers incorporated into the microemulsion are involved in the redispersion process and influence the size and shape of the redispersed BaSO4 particles in a specific way. The crystallization process mainly depends on the type of solvent and the polymer component added. In the presence of the cationic polyelectrolyte PDADMAC the crystallization to larger cubic crystals is inhibited, and layers consisting of polymer-stabilized spherical nanoparticles of BaSO4 (6 nm in size) will be observed. (c) 2004 Elsevier Inc. All rights reserved
The problem of atmospheric emission from OH molecules is a long standing problem for near-infrared astronomy. PRAXIS is a unique spectrograph which is fed by fibres that remove the OH background and is optimised specifically to benefit from OH-Suppression. The OH suppression is achieved with fibre Bragg gratings, which were tested successfully on the GNOSIS instrument. PRAXIS uses the same fibre Bragg gratings as GNOSIS in its first implementation, and will exploit new, cheaper and more efficient, multicore fibre Bragg gratings in the second implementation. The OH lines are suppressed by a factor of similar to 1000, and the expected increase in the signal-to-noise in the interline regions compared to GNOSIS is a factor of similar to 9 with the GNOSIS gratings and a factor of similar to 17 with the new gratings. PRAXIS will enable the full exploitation of OH suppression for the first time, which was not achieved by GNOSIS (a retrofit to an existing instrument that was not OH-Suppression optimised) due to high thermal emission, low spectrograph transmission and detector noise. PRAXIS has extremely low thermal emission, through the cooling of all significantly emitting parts, including the fore-optics, the fibre Bragg gratings, a long length of fibre, and the fibre slit, and an optical design that minimises leaks of thermal emission from outside the spectrograph. PRAXIS has low detector noise through the use of a Hawaii-2RG detector, and a high throughput through a efficient VPH based spectrograph. PRAXIS will determine the absolute level of the interline continuum and enable observations of individual objects via an IFU. In this paper we give a status update and report on acceptance tests.