Refine
Has Fulltext
- yes (14)
Document Type
- Postprint (14)
Language
- English (14) (remove)
Is part of the Bibliography
- no (14) (remove)
Keywords
- Diodenlaserspektroskopie (3)
- Fluoreszenz-Resonanz-Energie-Transfer (3)
- Immunoassay (3)
- Kohlendioxid (3)
- Energietransfer (2)
- Isotopenverhältnis (2)
- Lumineszenz (2)
- Quantenpunkt (2)
- carbon dioxide (2)
- carbon monoxide (2)
Institute
- Institut für Chemie (14) (remove)
The salivary glands of the blowfly were injected with luminescent oxygen-sensitive microbeads. The changes in oxygen content within individual gland tubules during hormone-induced secretory activity were quantified. The measurements are based on an upgraded phase-modulation technique, where the phase shift of the sensor phosphorescence is determined independently from concentration and background signals. We show that the combination of a lock-in amplifier with a fluorescence microscope results in a convenient setup to measure oxygen concentrations within living animal tissues at the cellular level.
A technique has been developed to measure absolute intracellular oxygen concentrations in green plants. Oxygen-sensitive phosphorescent microbeads were injected into the cells and an optical multifrequency phase-modulation technique was used to discriminate the sensor signal from the strong autofluorescence of the plant tissue. The method was established using photosynthesis-competent cells of the giant algae Chara corallina L., and was validated by application to various cell types of other plant species.
Investigations with frequency domain photon density waves allow elucidation of absorption and scattering properties of turbid media. The temporal and spatial propagation of intensity modulated light with frequencies up to more than 1 GHz can be described by the P1 approximation to the Boltzmann transport equation. In this study, we establish requirements for the appropriate choice of turbid model media and characterize mixtures of isosulfan blue as absorber and polystyrene beads as scatterer. For these model media, the independent determination of absorption and reduced scattering coefficients over large absorber and scatterer concentration ranges is demonstrated with a frequency domain photon density wave spectrometer employing intensity and phase measurements at various modulation frequencies.
Improvement of a fluorescence immunoassay with a compact diode-pumped solid state laser at 315 nm
(2006)
We demonstrate the improvement of fluorescence immunoassay (FIA) diagnostics in deploying a newly developed compact diode-pumped solid state (DPSS) laser with emission at 315 nm. The laser is based on the quasi-three-level transition in Nd:YAG at 946 nm. The pulsed operation is either realized by an active Q-switch using an electro-optical device or by introduction of a Cr<SUP>4+</SUP>:YAG saturable absorber as passive Q-switch element. By extra-cavity second harmonic generation in different nonlinear crystal media we obtained blue light at 473 nm. Subsequent mixing of the fundamental and the second harmonic in a β-barium-borate crystal provided pulsed emission at 315 nm with up to 20 μJ maximum pulse energy and 17 ns pulse duration. Substitution of a nitrogen laser in a FIA diagnostics system by the DPSS laser succeeded in considerable improvement of the detection limit. Despite significantly lower pulse energies (7 μJ DPSS laser versus 150 μJ nitrogen laser), in preliminary investigations the limit of detection was reduced by a factor of three for a typical FIA.
The drift time spectra of polycyclic aromatic hydrocarbons (PAH), alkylbenzenes and alkylphenylethers were recorded with a laser-based ion mobility (IM) spectrometer. The ion mobilities of all compounds were determined in helium as drift gas. This allows the calculation of the diffusion cross sections (Omegacalc) on the basis of the exact hard sphere scattering model (EHSSM) and their comparison with the experimentally determined diffusion cross sections (Omegaexp). These Omegaexp/Omegacalc-correlations are presented for molecules with a rigid structure like PAH and prove the reliability of the theoretical model and experimental method. The increase of the selectivity of IM spectrometry is demonstrated using resonance enhanced multiphoton ionisation (REMPI) at atmospheric pressure, realized by tuneable lasers. The REMPI spectra of nine alkylbenzenes and alkylphenylethers are investigated. On the basis of these spectra, the complete qualitative distinction of eight compounds in a mixture is shown. These experiments are extended to alkylbenzene isomer mixtures.
Two examples of our biophotonic research utilizing nanoparticles are presented, namely laser-based fluoroimmuno analysis and in-vivo optical oxygen monitoring. Results of the work include significantly enhanced sensitivity of a homogeneous fluorescence immunoassay and markedly improved spatial resolution of oxygen gradients in root nodules of a legume species.
Absorption and fluorescence properties of 4 hydraulic oils (3 biological and 1 petroleum-based) were investigated. In-situ LIF (laser-induced fluorescence) analysis of the oils on a brown sandy loam soil was performed. With calibration, quantitative detection was achieved. Estimated limits of detection were below ca. 500 mg/kg for the petroleum-based oil and ca. 2000 mg/kg for one biological oil. A semi-quantitative classification scheme is proposed for monitoring of the biological oils. This approach was applied to investigate the migration of a biological oil in soil-containing compartments, namely a soil column and a soil bed.
Near-infrared (NIR) absorption spectroscopy with tunable diode lasers allows the simultaneous detection of the three most important isotopologues of carbon dioxide (<SUP>12</SUP>CO<SUB>2</SUB>, <SUP>13</SUP>CO<SUB>2</SUB>, <SUP>12</SUP>C<SUP>18</SUP>O<SUP>16</SUP>O) and carbon monoxide (<SUP>12</SUP>CO, <SUP>13</SUP>CO, <SUP>12</SUP>C<SUP>18</SUP>O). The flexible and compact fiber-optic tunable diode laser absorption spectrometer (TDLAS) allows selective measurements of CO<SUB>2</SUB> and CO with high isotopic resolution without sample preparation since there is no interference with water vapour. For each species, linear calibration plots with a dynamic range of four orders of magnitude and detection limits (LOD) in the range of a few ppm were obtained utilizing wavelength modulation spectroscopy (WMS) with balanced detection in a Herriott-type multipass cell. The high performance of the apparatus is illustrated by fill-evacuation-refill cycles.
The performance of a home-built tunable diode laser (TDL) spectrometer has been optimized regarding multi-line detection of carbon dioxide in natural gases. In the regime of the (30<SUP>0</SUP>1)<SUB>III</SUB> ← (000) band of <SUP>12</SUP>CO<SUB>2</SUB> around 1.6 μm, the dominating isotope species <SUP>12</SUP>CO<SUB>2</SUB>, <SUP>13</SUP>CO<SUB>2</SUB>, and <SUP>12</SUP>C<SUP>18</SUP>O<SUP>16</SUP>O were detected simultaneously. In contrast to most established techniques, selective measurements are performed without any sample preparation. This is possible since the CO<SUB>2</SUB> detection is free of interference from water, ubiquitous in natural gases. Detection limits in the range of a few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. Linear calibration plots cover a dynamic range of four orders of magnitude, allowing for quantitative CO<SUB>2</SUB> detection in various samples, like soil and breath gas. High isotopic resolution enables the excellent selectivity, sensitivity, and stability of the chosen analytical concept. The obtained isotopic resolution of typically ± 1.0 ‰ and ± 1.5 ‰ (for 3 vol. % and 0.7 vol. % of CO<SUB>2</SUB>, respectively) offers a promising analytical tool for isotope-ratio determination of carbon dioxide in soil gas. Preliminary experiments on soil respiration for the first time combine the on-line quantification of the overall carbon dioxide content with an optode sensor and isotopic determination (TDL system) of natural gas species.
The performance of a home-built tunable diode laser (TDL) spectrometer, aimed at multi-line detection of carbon dioxide, has been evaluated and optimized. In the regime of the (30<SUP>0</SUP>1)<SUB>III</SUB> / (000) band of <SUP>12</SUP>CO<SUB>2</SUB> around 1.6 μm, the dominating isotope species <SUP>12</SUP>CO<SUB>2</SUB>, <SUP>13</SUP>CO<SUB>2</SUB>, and <SUP>12</SUP>C<SUP>18</SUP>O<SUP>16</SUP>O were detected simultaneously without interference by water vapor. Detection limits in the range of few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. High sensitivity in conjunction with high precision —typically ±1‰ and ±6‰ for 3% and 0.7% of CO<SUB>2</SUB>, respectively— renders this experimental approach a promising analytical concept for isotope-ratio determination of carbon dioxide in soil and breath gas. For a moderate <SUP>12</SUP>CO<SUB>2</SUB> line, the pressure dependence of the line profile was characterized in detail, to account for pressure effects on sensitive measurements.