There is controversy in the literature in regards of the link between training load and injury rate. Thus, the aims of this non-interventional study were to evaluate relationships between pre-season training load with biochemical markers, injury incidence and performance during the first month of the competitive period in professional soccer players.
The 933 km(2) Bengue catchment in northeastern Brazil is characterized by distinct rainy and dry seasons. Precipitation is stored in variously sized reservoirs, which is essential for the local population. In this study, we used TerraSAR-X SM(HH) data for an one-year monitoring of seasonal changes in the reservoir areas from July 2011 to July 2012. The monitoring was based on acquisitions in the ascending pass direction, complemented by occasional descending-pass images. To detect water surface areas, a histogram analysis followed by a global threshold classification was performed, and the results were validated using in situ GPS data. Distinguishing between small reservoirs and similar looking dark areas was difficult. Therefore, we tested several approaches for identifying misclassified areas. An analysis of the surface area dynamics of the reservoirs indicated high spatial and temporal heterogeneities and a large decrease in the total water surface area of the reservoirs in the catchment by approximately 30% within one year.
Vitamin A deficiency continues to be a global public health problem. Fortification of oil with vitamin A is considered a cost-effective, feasible strategy to prevent this problem but quality control poses a challenge to program implementation. To overcome this, we have validated a newly developed device that quantitatively measures the content of retinyl palmitate in refined palm oil, is simple to use, and yields immediate results.
Linearity of analysis rand from 2.5-30 mg retinol equivalents (RE)/kg of palm oil, with 2.5 mg RE/kg being the determination limit; inter- and intra-assay precision ranged from 1.4-7.1 To. Comparison with a high-performance Liquid chromatography method showed high agreement between the methods (R-2 = 0.92; Limits of Agreement: -1.24 mg to 2.53 mg RE/kg), and further comparisons illustrate that the new device is useful in low resource settings. This device offers a field- and user-friendly solution to quantifying the vitamin A content in refined palm oil.
Background. Despite considerable progress made in the past decade through salt iodization programs, over 2 billion people worldwide still have inadequate iodine intake, with devastating consequences for brain development and intellectual capacity. To optimize these programs with regard to salt iodine content, careful monitoring of salt iodine content is essential, but few methods are available to quantitatively measure iodine concentration in a simple, fast, and safe way.
Objective. We have validated a newly developed device that quantitatively measures the content of potassium iodate in salt in a simple, safe, and rapid way.
Methods. The linearity, determination and detection limit, and inter- and intra-assay variability of this colorimetric method were assessed and the method was compared with iodometric titration, using salt samples from several countries.
Results. Linearity of analysis ranged from 5 to 75 mg/kg iodine, with I mg/kg being the determination limit; the intra- and interassay imprecision was 0.9%, 0.5%, and 0.7% and 1.5%, 1.7%, and 2.5% for salt samples with iodine contents of 17, 30, and 55 mg/kg, respectively; the interoperator imprecision for the same samples was 1.2%, 4.9%, and 4.7%, respectively. Comparison with the iodometric method showed high agreement between the methods (R-2 = 0.978; limits of agreement, -10.5 to 10.0 mg/kg).
Conclusions. The device offers a field- and user-friendly solution to quantifying potassium iodate salt content reliably. For countries that use potassium iodide in salt iodization programs, further validation is required.