Refine
Language
- English (24)
Is part of the Bibliography
- yes (24)
Keywords
- biosensor (4)
- molecularly imprinted polymers (4)
- Electropolymerization (2)
- GABA (2)
- Redox marker (2)
- SEIRA spectroelectrochemistry (2)
- aldehyde oxidoreductase (2)
- benzaldehyde (2)
- biomimetic sensors (2)
- butyrylcholinesterase (2)
- electrochemistry (2)
- enzymatic MIP synthesis (2)
- enzymatic analyte conversion (2)
- enzyme catalysis (2)
- enzyme tracer (2)
- ionic strength (2)
- o-phenylenediamine (2)
- redox polymer (2)
- rivastigmine (2)
- template digestion (2)
- Bacterial biosensor (1)
- Biomarker (1)
- Cytochrome P450 (1)
- Direct electron transfer (1)
- Epitope imprinting (1)
- Hangman porphyrin (1)
- MIP (1)
- Molecularly Imprinted Polymers (1)
- Molecularly imprinted polymer (1)
- Molecularly imprinted polymers (1)
- N-ligands (1)
- Protein adsorption (1)
- Protein imprinting (1)
- Scopoletin (1)
- TMAO reductase (1)
- TMAO-reductase (1)
- Transferrin (1)
- activation of oxygen species (1)
- amination (1)
- amperometry (1)
- binding (1)
- carbon nanotubes (1)
- carbon nanotubes (CNTs) (1)
- carbon paper (1)
- cell viability assay (1)
- chimeric enzyme (1)
- cyclic voltammetry (1)
- direct electron transfer (1)
- electro-polymerization (1)
- electrochemical biosensor (1)
- electrochemical biosensors (1)
- electrosynthesis (1)
- enzymatic biofuel cell (1)
- epitope imprinting (1)
- glycated peptide (1)
- heme (1)
- heterogeneous catalysis (1)
- human sulfite oxidase (1)
- immobilization (1)
- immobilized enzyme (1)
- in situ scanning (1)
- laccase (1)
- mesoporous materials (1)
- microperoxidase (1)
- molybdoenzyme (1)
- multienzyme electrode (1)
- non-specific (1)
- oxygen scavenger (1)
- peptide imprinting (1)
- peroxidase mimics (1)
- peroxidases (1)
- phenols (1)
- redox gating (1)
- redox-active ligands (1)
- reduced graphene oxide (1)
- ruthenium (1)
- screen printed electrodes (SPEs) (1)
- self-assembled molecular monolayers (1)
- semiconductors (1)
- single-crystal gold electrodes (1)
- spectroelectrochemistry (1)
- sulfite oxidase (1)
- trimethylamine N-oxide (1)
- trimethylamine N-oxide (TMAO) (1)
- tunnelling spectroscopy (1)
- viologen (1)
Institute
- Institut für Biochemie und Biologie (24) (remove)
For the early detection of bacterial infection, there is a need for rapid, sensitive, and label-free assays. Thus, in this study, nanostrucured microbial electrochemical platform is designed to monitor the viability and cell growth of S. aureus. Using multi-walled carbon nanotube modified screen-printed electrodes (MWCNTs/SPE), the cyclic voltammetric measurements showed only one irreversible oxidation peak at 600 mV vs Ag/AgCl that accounts for the viable and metabolically active bacterial cells. The assay was optimized and the secreted metabolites, in the extracellular matrix, were directly detected. The peak current showed a positive correlation with viable cell numbers ranging from OD600 nm of 0.1 to 1.1, indicating that the activity of live cells can be quantified. Consequently, responses of viable and non-viable cells of S. aureus to the effects of antibiotic and respiratory chain inhibitors were determined. Thus, the proposed nanostructure-based bacterial sensor provides a reasonable and reliable way for real-time monitoring of live-dead cell functions, and antibacterial profiling.
Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range.
The thiophene-modified iron porphyrin FeT3ThP and the respective iron Hangman porphyrin FeH3ThP, incorporating a carboxylic acid hanging group in the second coordination sphere of the iron center, were electropolymerized on glassy carbon electrodes using 3,4-ethylenedioxythiophene (EDOT) as co-monomer. Scanning electron microscopy images and Resonance Raman spectra demonstrated incorporation of the porphyrin monomers into a fibrous polymer network. Porphyrin/polyEDOT films catalyzed the reduction of molecular oxygen in a four-electron reaction to water with onset potentials as high as +0.14V vs. Ag/AgCl in an aqueous solution of pH7. Further, FeT3ThP/polyEDOT films showed electrocatalytic activity towards reduction of hydrogen peroxide at highly positive potentials, which was significantly enhanced by introduction of the carboxylic acid hanging group in FeH3ThP. The second coordination sphere residue promotes formation of a highly oxidizing reaction intermediate, presumably via advantageous proton supply, as observed for peroxidases and catalases making FeH3ThP/polyEDOT films efficient mimics of heme enzymes.
Modulating the Molybdenum Coordination Sphere of Escherichia coli Trimethylamie N-Oxide Reductase
(2018)
The well-studied enterobacterium Escherichia coli present in the human gut can reduce trimethylamine N-oxide (TMAO) to trimethylamine during anaerobic respiration. The TMAO reductase TorA is a monomeric, bis-molybdopterin guanine dinucleotide (bis-MGD) cofactor-containing enzyme that belongs to the dimethyl sulfoxide reductase family of molybdoenzymes. We report on a system for the in vitro reconstitution of TorA with molybdenum cofactors (Moco) from different sources. Higher TMAO reductase activities for TorA were obtained when using Moco sources containing a sulfido ligand at the molybdenum atom. For the first time, we were able to isolate functional bis-MGD from Rhodobacter capsulatus formate dehydrogenase (FDH), which remained intact in its isolated state and after insertion into apo-TorA yielded a highly active enzyme. Combined characterizations of the reconstituted TorA enzymes by electron paramagnetic resonance spectroscopy and direct electrochemistry emphasize that TorA activity can be modified by changes in the Mo coordination sphere. The combination of these results together with studies of amino acid exchanges at the active site led us to propose a novel model for binding of the substrate to the molybdenum atom of TorA.
Molecularly imprinted polymer (MP) nanofilrns for transferrin (Trf) have been synthesized on gold surfaces by electro-polymerizing the functional monomer scopoletin in the presence of the protein target or around pre-adsorbed Trf. As determined by atomic force microscopy (AFM) the film thickness was comparable with the molecular dimension of the target. The target (re)binding properties of the electro-synthesized MIP films was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV) through the target-binding induced permeability changes of the MIP nanofilms to the ferricyanide redox marker, as well as by surface plasmon resonance (SPR) and surface enhanced infrared absorption spectroscopy (SEIRAS) of the immobilized protein molecules. For Trf a linear concentration dependence in the lower micromolar range and an imprinting factor of similar to 5 was obtained by SWV and SPR. Furthermore, non-target proteins including the iron-free apo-Trf were discriminated by pronounced size and shape specificity. Whilst it is generally assumed that the rebinding of the target or of cross-reacting proteins exclusively takes place at the polymer here we considered also the interaction of the protein molecules with the underlying gold transducers. We demonstrate by SWV that adsorption of proteins suppresses the signal of the redox marker even at the bare gold surface and by SEIRAS that the treatment of the MIP with proteinase K or NaOH only partially removes the target protein. Therefore, we conclude that when interpreting binding of proteins to directly MIP-covered gold electrodes the interactions between the protein and the gold surface should also be considered.
Hypothesis: Electrosynthesis of the MIP nano-film after binding of the separated domains or holocytochrome BM3 via an engineered anchor should result in domain-specific cavities in the polymer layer. Experiments: Both the two domains and the holo P450 BM3 have been bound prior polymer deposition via a N-terminal engineered his6-anchor to the electrode surface. Each step of MIP preparation was characterized by cyclic voltammetry of the redox-marker ferricyanide. Rebinding after template removal was evaluated by quantifying the suppression of the diffusive permeability of the signal for ferricyanide and by the NADH-dependent reduction of cytochrome c by the reductase domain (BMR). Findings: The working hypothesis is verified by the discrimination of the two domains by the respective MIPs: The holoenzyme P450 BM3 was ca. 5.5 times more effectively recognized by the film imprinted with the oxidase domain (BMO) as compared to the BMR-MIP or the non-imprinted polymer (NIP). Obviously, a cavity is formed during the imprinting process around the hiss-tag-anchored BMR which cannot accommodate the broader BMO or the P450 BM3. The affinity of the MIP towards P450 BM3 is comparable with that to the monomer in solution. The hiss-tagged P450 BM3 binds (30 percent) stronger which shows the additive effect of the interaction with the MIP and the binding to the electrode.
For the first time, an enzyme-based electrochemical biosensor system for determination of trimethylamine N-oxide (TMAO) is described. It employs an active chimeric variant of TorA in combination with an enzymatically deoxygenating system and a low-potential mediator for effective regeneration of the enzyme and cathodic current generation. TMAO reductase (TorA) is a molybdoenzyme found in marine and most enterobacteria that specifically catalyzes the reduction of TMAO to trimethylamine (TMA). The chimeric TorA, named TorA-FDH, corresponds to the apoform of TorA from Escherichia coli reconstituted with the molybdenum cofactor from formate dehydrogenase (FDH). Each enzyme, TorA and TorA-FDH, was immobilized on the surface of a carbon electrode and protected with a dialysis membrane. The biosensor operates at an applied potential of -0.8V [vs. Ag/AgCl (1M KCl)] under ambient air conditions thanks to an additional enzymatic O-2-scavenger system. A comparison between the two enzymatic sensors revealed a much higher sensitivity for the biosensor with immobilized TorA-FDH. This biosensor exhibits a sensitivity of 14.16nA/M TMAO in a useful measuring range of 2-110M with a detection limit of LOD=2.96nM (S/N=3), and was similar for TMAO in buffer and in spiked serum samples. With a response time of 16 +/- 2 s, the biosensor is stable over prolonged daily measurements (n=20). This electrochemical biosensor provides suitable applications in detecting TMAO levels in human serum.
Transient Catalytic Voltammetry of Sulfite Oxidase Reveals Rate Limiting Conformational Changes
(2017)
Sulfite oxidases are metalloenzymes that oxidize sulfite to sulfate at a molybdenum active site. In vertebrate sulfite oxidases, the electrons generated at the Mo center are transferred to an external electron acceptor via a heme domain, which can adopt two conformations: a “closed” conformation, suitable for internal electron transfer, and an “open” conformation suitable for intermolecular electron transfer. This conformational change is an integral part of the catalytic cycle. Sulfite oxidases have been wired to electrode surfaces, but their immobilization leads to a significant decrease in their catalytic activity, raising the question of the occurrence of the conformational change when the enzyme is on an electrode. We recorded and quantitatively modeled for the first time the transient response of the catalytic cycle of human sulfite oxidase immobilized on an electrode. We show that conformational changes still occur on the electrode, but at a lower rate than in solution, which is the reason for the decrease in activity of sulfite oxidases upon immobilization.
Molecularly imprinted polymers (MIPs) have the potential to complement antibodies in bioanalysis, are more stable under harsh conditions, and are potentially cheaper to produce. However, the affinity and especially the selectivity of MIPs are in general lower than those of their biological pendants. Enzymes are useful tools for the preparation of MIPs for both low and high-molecular weight targets: As a green alternative to the well-established methods of chemical polymerization, enzyme-initiated polymerization has been introduced and the removal of protein templates by proteases has been successfully applied. Furthermore, MIPs have been coupled with enzymes in order to enhance the analytical performance of biomimetic sensors: Enzymes have been used in MIP-sensors as tracers for the generation and amplification of the measuring signal. In addition, enzymatic pretreatment of an analyte can extend the analyte spectrum and eliminate interferences.
Molecularly imprinted polymers (MIPs) have the potential to complement antibodies in bioanalysis, are more stable under harsh conditions, and are potentially cheaper to produce. However, the affinity and especially the selectivity of MIPs are in general lower than those of their biological pendants. Enzymes are useful tools for the preparation of MIPs for both low and high-molecular weight targets: As a green alternative to the well-established methods of chemical polymerization, enzyme-initiated polymerization has been introduced and the removal of protein templates by proteases has been successfully applied. Furthermore, MIPs have been coupled with enzymes in order to enhance the analytical performance of biomimetic sensors: Enzymes have been used in MIP-sensors as tracers for the generation and amplification of the measuring signal. In addition, enzymatic pretreatment of an analyte can extend the analyte spectrum and eliminate interferences.