Refine
Document Type
- Article (16)
- Postprint (9)
- Doctoral Thesis (1)
- Other (1)
Language
- English (27) (remove)
Is part of the Bibliography
- yes (27)
Keywords
- reliability (27) (remove)
Institute
- Department Sport- und Gesundheitswissenschaften (5)
- Humanwissenschaftliche Fakultät (5)
- Department Psychologie (3)
- Strukturbereich Kognitionswissenschaften (3)
- Fakultät für Gesundheitswissenschaften (2)
- Institut für Ernährungswissenschaft (2)
- Institut für Informatik und Computational Science (2)
- Department Linguistik (1)
- Hasso-Plattner-Institut für Digital Engineering GmbH (1)
- Hasso-Plattner-Institut für Digital Engineering gGmbH (1)
Our experimental approach included two studies to determine discriminative validity and test-retest reliability (study 1) as well as ecological validity (study 2) of a judo ergometer system while performing judo-specific movements. Sixteen elite (age: 23 +/- 3 years) and 11 sub-elite (age: 16 +/- 1 years) athletes participated in study 1 and 14 male sub-elite judo athletes participated in study 2. Discriminative validity and test-retest reliability of sport-specific parameters (mechanical work, maximal force) were assessed during pulling movements with and without tsukuri (kuzushi). Ecological validity of muscle activity was determined by performing pulling movements using the ergometer without tsukuri and during the same movements against an opponent. In both conditions, electromyographic activity of trunk (e.g., m. erector spinae) and upper limb muscles (e.g., m. biceps brachii) were assessed separately for the lifting and pulling arm. Elite athletes showed mostly better mechanical work, maximal force, and power (0.12 <= d <= 1.80) compared with sub-elite athletes. The receiver operating characteristic analysis revealed acceptable validity of the JERGo(C) system to discriminate athletes of different performance levels predominantly during kuzushi without tsukuri (area under the curve = 0.27-0.90). Moreover, small-to-medium discriminative validity was found to detect meaningful performance changes for mechanical work and maximal force. The JERGo(C) system showed small-to-high relative (ICC = 0.37-0.92) and absolute reliability (SEM = 10.8-18.8%). Finally, our analyses revealed acceptable correlations (r = 0.41-0.88) between muscle activity during kuzushi performed with the JERGo(C) system compared with a judo opponent. Our findings indicate that the JERGo(C) system is a valid and reliable test instrument for the assessment and training of judo-specific pulling kinetics particularly during kuzushi movement without tsukuri.
The aim of this study was to assess the ability of the FFQ to describe reliable and valid dietary pattern (DP) scores. In a total of 134 participants of the European Prospective Investigation into Cancer and Nutrition-Potsdam study aged 35-67 years, the FFQ was applied twice (baseline and after 1 year) to assess its reliability. Between November 1995 and March 1997, twelve 24-h dietary recalls (24HDR) as reference instrument were applied to assess the validity of the FFQ. Exploratory DP were derived by principal component analyses. Investigated predefined DP were the Alternative Healthy Eating Index (AHEI) and two Mediterranean diet indices. From dietary data of each FFQ, two exploratory DP were retained, but differed in highly loading food groups, resulting in moderate correlations (r 0 center dot 45-0 center dot 58). The predefined indices showed higher correlations between the FFQ (r(AHEI) 0 center dot 62, r(Mediterranean Diet Pyramid Index (MedPyr)) 0 center dot 62 and r(traditional Mediterranean Diet Score (tMDS)) 0 center dot 51). From 24HDR dietary data, one exploratory DP retained differed in composition to the first FFQ-based DP, but showed similarities to the second DP, reflected by a good correlation (r 0 center dot 70). The predefined DP correlated moderately (r 0 center dot 40-0 center dot 60). To conclude, long-term analyses on exploratory DP should be interpreted with caution, due to only moderate reliability. The validity differed extensively for the two exploratory DP. The investigated predefined DP showed a better reliability and a moderate validity, comparable to other studies. Within the two Mediterranean diet indices, the MedPyr performed better than the tMDs in this middle-aged, semi-urban German study population.
The aim of this study was to assess the ability of the FFQ to describe reliable and valid dietary pattern (DP) scores. In a total of 134 participants of the European Prospective Investigation into Cancer and Nutrition-Potsdam study aged 35-67 years, the FFQ was applied twice (baseline and after 1 year) to assess its reliability. Between November 1995 and March 1997, twelve 24-h dietary recalls (24HDR) as reference instrument were applied to assess the validity of the FFQ. Exploratory DP were derived by principal component analyses. Investigated predefined DP were the Alternative Healthy Eating Index (AHEI) and two Mediterranean diet indices. From dietary data of each FFQ, two exploratory DP were retained, but differed in highly loading food groups, resulting in moderate correlations (r 0 center dot 45-0 center dot 58). The predefined indices showed higher correlations between the FFQ (r(AHEI) 0 center dot 62, r(Mediterranean Diet Pyramid Index (MedPyr)) 0 center dot 62 and r(traditional Mediterranean Diet Score (tMDS)) 0 center dot 51). From 24HDR dietary data, one exploratory DP retained differed in composition to the first FFQ-based DP, but showed similarities to the second DP, reflected by a good correlation (r 0 center dot 70). The predefined DP correlated moderately (r 0 center dot 40-0 center dot 60). To conclude, long-term analyses on exploratory DP should be interpreted with caution, due to only moderate reliability. The validity differed extensively for the two exploratory DP. The investigated predefined DP showed a better reliability and a moderate validity, comparable to other studies. Within the two Mediterranean diet indices, the MedPyr performed better than the tMDs in this middle-aged, semi-urban German study population.
This research was designed to adapt and investigate the psychometric properties of the Short Dark Triad measure (Jones and Paulhus Assessment, 21(1), 28-41, 2014) in a German sample within four studies (total N = 1463); the measure evaluates three personality dimensions: narcissism, psychopathy, and Machiavellianism. The structure of the instrument was analysed by Confirmatory Factor Analyses procedure. It indicated that the three-factor structure had the best fit to the data. Next, the Short Dark Triad measure was evaluated in terms of construct, convergent and discriminant validity, internal consistency (≥ .72), and test-retest reliability during a 4-week period (≥ .73). Concurrent validity of the SD3 was supported by relating its subscales to measures of the Big Five concept, aggression, and self-esteem. We concluded that the Short Dark Triad instrument presented high cross-language replicability. The use of this short inventory in the investigation of the Dark Triad personality model in the German language context is suggested.
Background
Elderly patients are a growing population in cardiac rehabilitation (CR). As postural control declines with age, assessment of impaired balance is important in older CR patients in order to predict fall risk and to initiate counteracting steps. Functional balance tests are subjective and lack adequate sensitivity to small differences, and are further subject to ceiling effects. A quantitative approach to measure postural control on a continuous scale is therefore desirable. Force plates are already used for this purpose in other clinical contexts, therefore could be a promising tool also for older CR patients. However, in this population the reliability of the assessment is not fully known.
Research question
Analysis of test-retest reliability of center of pressure (CoP) measures for the assessment of postural control using a force plate in older CR patients.
Methods
156 CR patients (> 75 years) were enrolled. CoP measures (path length (PL), mean velocity (MV), and 95% confidence ellipse area (95CEA)) were analyzed twice with an interval of two days in between (bipedal narrow stance, eyes open (EO) and closed (EC), three trials for each condition, 30 s per trial), using a force plate. For test-retest reliability estimation absolute differences (& UDelta;: T0-T1), intraclass correlation coefficients (ICC) with 95% confidence intervals, standard error of measurement and minimal detectable change were calculated.
Results
Under EO condition ICC were excellent for PL and MV (0.95) and good for 95CEA (0.88) with & UDelta; of 10.1 cm (PL), 0.3 cm/sec (MV) and 1.5 cm(2 )(95CEA) respectively. Under EC condition ICC were excellent (> 0.95) for all variables with larger & UDelta; (PL: 21.7 cm; MV: 0.7 cm/sec; 95CEA: 2.4 cm(2))
Significance
In older CR patients, the assessment of CoP measures using a force plate shows good to excellent test retest reliability.
The intensity of cosmic radiation may differ over five orders of magnitude within a few hours or days during the Solar Particle Events (SPEs), thus increasing for several orders of magnitude the probability of Single Event Upsets (SEUs) in space-borne electronic systems. Therefore, it is vital to enable the early detection of the SEU rate changes in order to ensure timely activation of dynamic radiation hardening measures. In this paper, an embedded approach for the prediction of SPEs and SRAM SEU rate is presented. The proposed solution combines the real-time SRAM-based SEU monitor, the offline-trained machine learning model and online learning algorithm for the prediction. With respect to the state-of-the-art, our solution brings the following benefits: (1) Use of existing on-chip data storage SRAM as a particle detector, thus minimizing the hardware and power overhead, (2) Prediction of SRAM SEU rate one hour in advance, with the fine-grained hourly tracking of SEU variations during SPEs as well as under normal conditions, (3) Online optimization of the prediction model for enhancing the prediction accuracy during run-time, (4) Negligible cost of hardware accelerator design for the implementation of selected machine learning model and online learning algorithm. The proposed design is intended for a highly dependable and self-adaptive multiprocessing system employed in space applications, allowing to trigger the radiation mitigation mechanisms before the onset of high radiation levels.
Reliability tests for wavelength-stabilized compact diode laser systems emitting at 671 nm are presented. The devices were mounted on microoptical benches with the dimensions of 13 mm x 4 mm. Reflecting Bragg gratings were used for wavelength stabilization and emission width narrowing. The reliability tests were performed at 25 degrees C and at an output power up to 10 mW per micrometer stripe width of the gain medium. Reliable operation could be demonstrated over a test time up to 14 500 h at an output power up to 1.0 W. Environmental tests using random vibrations with acceleration up to 29 g were performed without deterioration of the devices.
This paper proposes an education approach for master and bachelor students to enhance their skills in the area of reliability, safety and security of the electronic components in automated driving. The approach is based on the active synergetic work of research institutes, academia and industry in the frame of joint lab. As an example, the jointly organized summer school with the respective focus is organized and elaborated.
This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.