Refine
Has Fulltext
- no (18)
Year of publication
Document Type
- Article (18)
Language
- English (18)
Is part of the Bibliography
- yes (18)
Keywords
- capacitive sensor (2)
- structural health monitoring (2)
- Capacitive sensor (1)
- Dielectric elastomer (1)
- Dielectric materials (1)
- Dielectric polymer (1)
- EAP (1)
- Flexible membrane (1)
- Monitoring (1)
- Permittivity (1)
- Phase transition (1)
- Polymer-dispersed liquid crystal (1)
- Probe instruments (1)
- Sensing skin (1)
- Snap-through instability (1)
- Strain gages (1)
- Strain gauge (1)
- Strain monitoring (1)
- Stretchable sensor (1)
- Structural health monitoring (1)
- Surface treatment (1)
- Viscoelasticity (1)
- Wrinkling (1)
- actuator (1)
- compliant electrodes (1)
- dielectric elastomer (1)
- dielectric polymer (1)
- elastic conductor (1)
- electroactive polymer (1)
- electromechanically active polymer (1)
- ferroelectric polymer (1)
- ionic conductivity (1)
- ionic liquids (1)
- ionogels (1)
- large-scale system (1)
- liquid crystal alignment (1)
- mechanical properties (1)
- microstructure (1)
- nondestructive testing (1)
- phase separation (1)
- remanent polarisation (1)
- sensing skin (1)
- soft elastomeric capacitor (1)
- soft electrical connections (1)
- standard (1)
- strain monitoring (1)
- stretchable electronics (1)
- stretchable sensor (1)
- transducer (1)
- vibration monitoring (1)
Institute
- Institut für Physik und Astronomie (18) (remove)
Dielectric elastomer transducers consist of thin electrically insulating elastomeric membranes coated on both sides with compliant electrodes. They are a promising electromechanically active polymer technology that may be used for actuators, strain sensors, and electrical generators that harvest mechanical energy. The rapid development of this field calls for the first standards, collecting guidelines on how to assess and compare the performance of materials and devices. This paper addresses this need, presenting standardized methods for material characterisation, device testing and performance measurement. These proposed standards are intended to have a general scope and a broad applicability to different material types and device configurations. Nevertheless, they also intentionally exclude some aspects where knowledge and/or consensus in the literature were deemed to be insufficient. This is a sign of a young and vital field, whose research development is expected to benefit from this effort towards standardisation.
Polymer-dispersed liquid crystals (PDLCs) of ferroelectric poly(vinylidene fluoride-trifluoroethylene) and nematic 4-cyano-4ʹ-n-hexylbiphenyl (6CB) or 4-cyano-4ʹ-n-pentylbiphenyl (5CB) were prepared to study the effect of the remanent polarisation of the polymer on the liquid crystal alignment. We measured the macroscopic alignment of the liquid crystal molecules in the thickness direction by means of Infrared Transition-Moment Orientational Analysis. Electrical poling at 100 V/µm caused an increased order parameter up to 0.15. After subsequent annealing above the nematic-to-isotropic phase-transition temperature, the order parameter was reduced to 0.02. Nevertheless, the order parameter was still higher than for non-poled film indicating a slight orientation in thickness direction. Both values are lower than those expected from model calculations. In agreement with dielectric measurements, we attribute this result to the shielding effect of mobile charge carriers within the liquid crystal inclusions.
Dielectric elastomer transducers are being developed for applications in stretchable electronics, tunable optics, biomedical devices, and soft machines. These transducers exhibit highly nonlinear electromechanical behavior: a dielectric membrane under voltage can form wrinkles, undergo snap-through instability, and suffer electrical breakdown. We investigate temporal evolution and instability by conducting a large set of experiments under various prestretches and loading rates, and by developing a model that allows viscoelastic instability. We use the model to classify types of instability, and map the experimental observations according to prestretches and loading rates. The model describes the entire set of experimental observations. A new type of instability is discovered, which we call wrinkle-to-wrinkle transition. A flat membrane at a critical voltage forms wrinkles and then, at a second critical voltage, snaps into another state of winkles of a shorter wavelength. This study demonstrates that viscoelasticity is essential to the understanding of temporal evolution and instability of dielectric elastomers. (C) 2014 Elsevier Ltd. All rights reserved.
Strain sensors based on dielectric elastomer capacitors function by the direct coupling of mechanical deformations with the capacitance. The coupling can be improved by enhancing the relative permittivity of the dielectric elastomer. Here, this is carried out through the grafting of conducting polymer (poly-aniline) to the elastomer backbone, leading to molecular composites. An enhancement in capacitance response of 46 times is observed. This could help to extend the possible range of miniaturization towards even smaller device features.
A combination of experiment and theory shows that dielectric elastomers exhibit complex interplay of nonlinear processes. Membranes of a dielectric elastomer are prepared in various states of prestretches by using rigid clamps and mechanical forces. Upon actuation by voltage, some membranes form wrinkles followed by snap-through instability, others form wrinkles without the snap-through instability, and still others fail by local instability without forming wrinkles. Membranes surviving these nonlinear processes are found to attain a constant dielectric strength, independent of the state of prestretches. Giant voltage-induced stretch of 3.6 is attained.
Structural integrity of infrastructures can be preserved if damage is diagnosed, localized, and repaired in time. During the past decade, there has been a considerable effort to automate the process of structural health monitoring, which is complicated by the inherent large size of civil structures. Hence, a need has arisen to develop new approaches that enable more effective health monitoring.
In this paper, a new sensing technique for damage localization on large civil structures is proposed. Specifically, changes in strain are detected using a capacitance sensor built with a soft, stretchable dielectric polymer with attached stretchable metal film electrodes. A change in strain causes a measurable change in the capacitance of the sensor, which can be directly monitored when the sensor is fixed to a structure.
The proposed method is shown here to permit an accurate detection of cracks. The proposed system deploys a layer of dielectric polymer on the surface of a structural element, and regularly monitors any change in capacitance, giving in turn information about the structural state. The smart material is composed of inexpensive silicone elastomers, which make the monitoring system a promising application for large surfaces. Results from tests conducted on small- scale specimens showed that the technology is capable of detecting cracks, and tests conducted on large- size specimens demonstrated that several sensor patches organized on a sensor sheet are capable of localizing a crack. The sensor strain also exhibits a high correlation with the loss of stiffness.
Early detection of possible defects in civil infrastructure is vital to ensuring timely maintenance and extending structure life expectancy. The authors recently proposed a novel method for structural health monitoring based on soft capacitors. The sensor consisted of an off-the-shelf flexible capacitor that could be easily deployed over large surfaces, the main advantages being cost-effectiveness, easy installation, and allowing simple signal processing. In this paper, a capacitive sensor with tailored mechanical and electrical properties is presented, resulting in greatly improved robustness while retaining measurement sensitivity. The sensor is fabricated from a thermoplastic elastomer mixed with titanium dioxide and sandwiched between conductive composite electrodes. Experimental verifications conducted on wood and concrete specimens demonstrate the improved robustness, as well as the ability of the sensing method to diagnose and locate strain.
Contactless pressure monitoring based on Forster resonance energy transfer between donor/acceptor pairs immobilized within elastomers is demonstrated. The donor/acceptor energy transfer is employed by dispersing terbium(III) tris[(2-hydroxybenzoyl)-2-aminoethyl] amine complex (LLC, donor) and CdSe/ZnS quantum dots (QD655, acceptor) in styrene-ethylene/buthylene-styrene (SEBS) and poly(dimethylsiloxane) (PDMS). The continuous monitoring of QD luminescence showed a reversible intensity change as the pressure signal is alternated between two stable states indicating a pressure sensitivity of 6350 cps kPa(-1). Time-resolved measurements show the pressure impact on the FRET signal due to an increase of decay time (270 ms up to 420 ms) for the donor signal and parallel drop of decay time (170 mu s to 155 mu s) for the acceptor signal as the net pressure applied. The LLC/QD655 sensors enable a contactless readout as well as space resolved monitoring to enable miniaturization towards smaller integrated stretchable opto-electronics. Elastic FRET sensors can potentially lead to developing profitable analysis systems capable to outdo conventional wired electronic systems (inductive, capacitive, ultrasonic and photoelectric sensors) especially for point-of-care diagnostics, biological monitoring required for wearable electronics.
Holographic Structuring of Elastomer Actuator: First True Monolithic Tunable Elastomer Optics
(2016)
Volume diffraction gratings (VDGs) are inscribed selectively by diffusive introduction of benzophenone and subsequent UV-holographic structuring into an electroactive dielectric elastomer actuator (DEA), to afford a continuous voltage-controlled grating shift of 17%. The internal stress coupling of DEA and optical domain allows for a new generation of true monolithic tunable elastomer optics with voltage controlled properties.