The regular monitoring of physical fitness and sport-specific performance is important in elite sports to increase the likelihood of success in competition. This study aimed to systematically review and to critically appraise the methodological quality, validation data, and feasibility of the sport-specific performance assessment in Olympic combat sports like amateur boxing, fencing, judo, karate, taekwondo, and wrestling. A systematic search was conducted in the electronic databases PubMed, Google-Scholar, and Science-Direct up to October 2017. Studies in combat sports were included that reported validation data (e.g., reliability, validity, sensitivity) of sport-specific tests. Overall, 39 studies were eligible for inclusion in this review. The majority of studies (74%) contained sample sizes <30 subjects. Nearly, 1/3 of the reviewed studies lacked a sufficient description (e.g., anthropometrics, age, expertise level) of the included participants. Seventy-two percent of studies did not sufficiently report inclusion/exclusion criteria of their participants. In 62% of the included studies, the description and/or inclusion of a familiarization session (s) was either incomplete or not existent. Sixty-percent of studies did not report any details about the stability of testing conditions. Approximately half of the studies examined reliability measures of the included sport-specific tests (intraclass correlation coefficient [ICC] = 0.43–1.00). Content validity was addressed in all included studies, criterion validity (only the concurrent aspect of it) in approximately half of the studies with correlation coefficients ranging from r = −0.41 to 0.90. Construct validity was reported in 31% of the included studies and predictive validity in only one. Test sensitivity was addressed in 13% of the included studies. The majority of studies (64%) ignored and/or provided incomplete information on test feasibility and methodological limitations of the sport-specific test. In 28% of the included studies, insufficient information or a complete lack of information was provided in the respective field of the test application. Several methodological gaps exist in studies that used sport-specific performance tests in Olympic combat sports. Additional research should adopt more rigorous validation procedures in the application and description of sport-specific performance tests in Olympic combat sports.
The regular monitoring of physical fitness and sport-specific performance is important in elite sports to increase the likelihood of success in competition. This study aimed to systematically review and to critically appraise the methodological quality, validation data, and feasibility of the sport-specific performance assessment in Olympic combat sports like amateur boxing, fencing, judo, karate, taekwondo, and wrestling. A systematic search was conducted in the electronic databases PubMed, Google-Scholar, and Science-Direct up to October 2017. Studies in combat sports were included that reported validation data (e.g., reliability, validity, sensitivity) of sport-specific tests. Overall, 39 studies were eligible for inclusion in this review. The majority of studies (74%) contained sample sizes <30 subjects. Nearly, 1/3 of the reviewed studies lacked a sufficient description (e.g., anthropometrics, age, expertise level) of the included participants. Seventy-two percent of studies did not sufficiently report inclusion/exclusion criteria of their participants. In 62% of the included studies, the description and/or inclusion of a familiarization session (s) was either incomplete or not existent. Sixty-percent of studies did not report any details about the stability of testing conditions. Approximately half of the studies examined reliability measures of the included sport-specific tests (intraclass correlation coefficient [ICC] = 0.43–1.00). Content validity was addressed in all included studies, criterion validity (only the concurrent aspect of it) in approximately half of the studies with correlation coefficients ranging from r = −0.41 to 0.90. Construct validity was reported in 31% of the included studies and predictive validity in only one. Test sensitivity was addressed in 13% of the included studies. The majority of studies (64%) ignored and/or provided incomplete information on test feasibility and methodological limitations of the sport-specific test. In 28% of the included studies, insufficient information or a complete lack of information was provided in the respective field of the test application. Several methodological gaps exist in studies that used sport-specific performance tests in Olympic combat sports. Additional research should adopt more rigorous validation procedures in the application and description of sport-specific performance tests in Olympic combat sports.
This research was designed to adapt and investigate the psychometric properties of the Short Dark Triad measure (Jones and Paulhus Assessment, 21(1), 28-41, 2014) in a German sample within four studies (total N = 1463); the measure evaluates three personality dimensions: narcissism, psychopathy, and Machiavellianism. The structure of the instrument was analysed by Confirmatory Factor Analyses procedure. It indicated that the three-factor structure had the best fit to the data. Next, the Short Dark Triad measure was evaluated in terms of construct, convergent and discriminant validity, internal consistency (≥ .72), and test-retest reliability during a 4-week period (≥ .73). Concurrent validity of the SD3 was supported by relating its subscales to measures of the Big Five concept, aggression, and self-esteem. We concluded that the Short Dark Triad instrument presented high cross-language replicability. The use of this short inventory in the investigation of the Dark Triad personality model in the German language context is suggested.
The aim of this study was to assess the ability of the FFQ to describe reliable and valid dietary pattern (DP) scores. In a total of 134 participants of the European Prospective Investigation into Cancer and Nutrition-Potsdam study aged 35-67 years, the FFQ was applied twice (baseline and after 1 year) to assess its reliability. Between November 1995 and March 1997, twelve 24-h dietary recalls (24HDR) as reference instrument were applied to assess the validity of the FFQ. Exploratory DP were derived by principal component analyses. Investigated predefined DP were the Alternative Healthy Eating Index (AHEI) and two Mediterranean diet indices. From dietary data of each FFQ, two exploratory DP were retained, but differed in highly loading food groups, resulting in moderate correlations (r 0 center dot 45-0 center dot 58). The predefined indices showed higher correlations between the FFQ (r(AHEI) 0 center dot 62, r(Mediterranean Diet Pyramid Index (MedPyr)) 0 center dot 62 and r(traditional Mediterranean Diet Score (tMDS)) 0 center dot 51). From 24HDR dietary data, one exploratory DP retained differed in composition to the first FFQ-based DP, but showed similarities to the second DP, reflected by a good correlation (r 0 center dot 70). The predefined DP correlated moderately (r 0 center dot 40-0 center dot 60). To conclude, long-term analyses on exploratory DP should be interpreted with caution, due to only moderate reliability. The validity differed extensively for the two exploratory DP. The investigated predefined DP showed a better reliability and a moderate validity, comparable to other studies. Within the two Mediterranean diet indices, the MedPyr performed better than the tMDs in this middle-aged, semi-urban German study population.
The aim of this study was to assess the ability of the FFQ to describe reliable and valid dietary pattern (DP) scores. In a total of 134 participants of the European Prospective Investigation into Cancer and Nutrition-Potsdam study aged 35-67 years, the FFQ was applied twice (baseline and after 1 year) to assess its reliability. Between November 1995 and March 1997, twelve 24-h dietary recalls (24HDR) as reference instrument were applied to assess the validity of the FFQ. Exploratory DP were derived by principal component analyses. Investigated predefined DP were the Alternative Healthy Eating Index (AHEI) and two Mediterranean diet indices. From dietary data of each FFQ, two exploratory DP were retained, but differed in highly loading food groups, resulting in moderate correlations (r 0 center dot 45-0 center dot 58). The predefined indices showed higher correlations between the FFQ (r(AHEI) 0 center dot 62, r(Mediterranean Diet Pyramid Index (MedPyr)) 0 center dot 62 and r(traditional Mediterranean Diet Score (tMDS)) 0 center dot 51). From 24HDR dietary data, one exploratory DP retained differed in composition to the first FFQ-based DP, but showed similarities to the second DP, reflected by a good correlation (r 0 center dot 70). The predefined DP correlated moderately (r 0 center dot 40-0 center dot 60). To conclude, long-term analyses on exploratory DP should be interpreted with caution, due to only moderate reliability. The validity differed extensively for the two exploratory DP. The investigated predefined DP showed a better reliability and a moderate validity, comparable to other studies. Within the two Mediterranean diet indices, the MedPyr performed better than the tMDs in this middle-aged, semi-urban German study population.
Introduction General and particularly sport-specific testing is an integral aspect of performance optimization in artistic gymnastics. In artistic gymnastics, however, only non-specific field tests have been used to assess endurance performance (e.g., Multistage Shuttle Run Test; Cooper's Test).
Methods This study aimed to examine the validity of a new sport-specific endurance test in artistic gymnastics. Fourteen elite-level gymnasts (i.e., eight males and six females) participated in this study. The newly developed artistic gymnastics-specific endurance test (AGSET) was conducted on two different occasions seven days apart to determine its reliability. To assess the concurrent validity of AGSET, participants performed the multistage shuttle run test (MSRT). Maximum oxygen uptake (VO2max) and respiratory exchange ratio (RER) were directly assessed using a portable gas analyzer system during both protocols. Additionally, the total time maintained (TTM) during the AGSET, maximum heart rate (HRmax), maximal aerobic speed (MAS), and blood lactate concentration (BLa) during the two protocols were collected.
Results The main findings indicated that all variables derived from the AGSET (i.e., VO2max, MAS, HRmax, BLa, and RER) displayed very good relative (all intraclass correlation coefficients [ICC] > 0.90) and absolute (all typical errors of measurement [TEM] < 5%) reliability. Further, results showed that the ability of the AGSET to detect small changes in VO2max, MAS, BLa, and RER was good (smallest worthwhile change [SWC0.2] > TEM), except HRmax (SWC0.2 < TEM). Additionally, results showed a nearly perfect association between the VO2max values derived from the AGSET and MSRT (r = 0.985; coefficient of determination [R-2] = 97%) with no statistically significant differences (p>0.05). The mean (bias) +/- 95% limits of agreement between the two protocols were 0.28 +/- 0.55 mlminkg-1.
Discussion AGSET seems to present very good reliability and concurrent validity for assessing endurance performance in elite artistic gymnastics. In addition, the newly developed protocol presents a good ability to detect small changes in performance.
Background: Isokinetic measurements are widely used to assess strength capacity in a clinical or research context. Nevertheless, the validity of isokinetic measures for identifying strength deficits and the evaluation of therapeutic process regarding different pathologies is yet to be established. Therefore, the purpose of this review is to evaluate the validity of isokinetic measures in a specific case: that of muscular capacity in low back pain (LBP).
Methods: A literature search (PubMed; ISI Web of Knowledge; The Cochrane Library) covering the last 10 years was performed. Relevant papers regarding isokinetic trunk strength measures in healthy and patients with low back pain (PLBP) were searched. Peak torque values [Nm] and peak torque normalized to body weight [Nm/kg BW] were extracted for healthy and PLBP. Ranked mean values across studies were calculated for the concentric peak torque at 60 degrees/s as well as the flexion/extension (F/E) ratio.
Results: 34 publications (31 flexion/extension; 3 rotation) were suitable for reporting detailed isokinetic strength measures in healthy or LBP (untrained adults, adolescents, athletes). Adolescents and athletes were different compared to normal adults in terms of absolute trunk strength values and the F/E ratio. Furthermore, isokinetic measures evaluating therapeutic process and isokinetic rehabilitation training were infrequent in literature (8 studies).
Conclusion: Isokinetic measurements are valid for measuring trunk flexion/extension strength and F/E ratio in athletes, adolescents and (untrained) adults with/without LBP. The validity of trunk rotation is questionable due to a very small number of publications whereas no reliable source regarding lateral flexion could be traced. Therefore, isokinetic dynamometry may be utilized for identifying trunk strength deficits in healthy adults and PLBP.