Refine
Year of publication
Document Type
- Article (26)
- Review (7)
- Postprint (6)
- Doctoral Thesis (1)
Is part of the Bibliography
- yes (40) (remove)
Keywords
- molecularly imprinted polymers (14)
- Molecularly imprinted polymers (7)
- Electropolymerization (5)
- biomimetic sensors (5)
- Biosensors (4)
- electropolymerization (4)
- Biomimetic sensors (3)
- Cytochrome P450 (3)
- direct electron transfer (3)
- Direct electron transfer (2)
- Epitope imprinting (2)
- Microperoxidase-11 (2)
- Molecularly imprinted polymer (2)
- Nanoparticles (2)
- Proteins (2)
- Redox marker (2)
- SEIRA spectroelectrochemistry (2)
- SELEX (2)
- Scopoletin (2)
- anticancer drug (2)
- aptamers (2)
- aptasensors (2)
- bioelectrocatalysis (2)
- biomimetic recognition elements (2)
- butyrylcholinesterase (2)
- catalysis (2)
- chemical sensors (2)
- electropolymerisation (2)
- enzymatic MIP synthesis (2)
- enzymatic analyte conversion (2)
- enzyme tracer (2)
- gate effect (2)
- hydrogen peroxide (2)
- in vitro selection (2)
- o-phenylenediamine (2)
- redox marker (2)
- rivastigmine (2)
- self-assembled monolayer (2)
- tamoxifen (2)
- template digestion (2)
- 4-Fluoroaniline (1)
- ATP (1)
- Aniline (1)
- Bioelectrocatalysis (1)
- Biomarker (1)
- Catalytically active MIPs (1)
- Catalytically active molecularly imprinted polymers (1)
- Catechol (1)
- Cellobiose dehydrogenase (1)
- Cytochrome c (1)
- Daptomycin (1)
- Enzymatic recycling (1)
- Esterase (1)
- Functional scaffolds (1)
- HPLC (1)
- HTHP (1)
- Hexokinase (1)
- Hybrid nanofilms (1)
- Hydrogen peroxide (1)
- Laccase (1)
- MIP (1)
- Microperoxidase (1)
- Microperoxidases (1)
- Molecularly Imprinted Polymers (1)
- Monoclonal MIPs (1)
- Multiwalled carbon nanotube (1)
- Nanohybrid (1)
- Nanostructuring (1)
- Paracetamol (1)
- Peroxidatic activity (1)
- Personalised medicine (1)
- Personalized medicine (1)
- Phenacetin (1)
- Phenolic substances (1)
- Plastibodies (1)
- Poylaniline (1)
- Protein adsorption (1)
- Protein imprinting (1)
- Pyruvate kinase (1)
- Superoxide (1)
- Surface imprinting (1)
- Third generation sensor (1)
- Transferrin (1)
- Tyrosinase (1)
- Unspecific peroxygenase (1)
- acetylcholinesterase (1)
- binding (1)
- direct electron (1)
- drug imprinting (1)
- drug sensors (1)
- electrochemical sensors (1)
- electrochemistry (1)
- electron transfer (1)
- electropolymers (1)
- electrosynthesis (1)
- enzymes (1)
- epitope imprinting (1)
- glycated peptide (1)
- gold (1)
- heme proteins (1)
- hierarchical structures (1)
- hydrochlorothiazide (1)
- irbesartan (1)
- modified electrodes (1)
- molecular modeling (1)
- molecularly imprinted electropolymers (1)
- molecularly imprinted polymer (1)
- monolayers (1)
- nanoparticles (1)
- non-specific (1)
- ophenylenediamine (1)
- p-Aminophenol (1)
- peptide imprinting (1)
- peripheral anionic site (1)
- pharmaceutical dosage forms (1)
- platinum nanoparticles (1)
- propidium (1)
- redox gating (1)
- scopoletin (1)
- transfer (1)
- tyrosinase (1)
Institute
Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range.
Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range.
Surface-Tuned Electron Transfer and Electrocatalysis of Hexameric Tyrosine-Coordinated Heme Protein
(2015)
Molecular modeling, electrochemical methods, and quartz crystal microbalance were used to characterize immobilized hexameric tyrosine-coordinated heme protein (HTHP) on bare carbon or on gold electrodes modified with positively and negatively charged self-assembled monolayers (SAMs), respectively. HTHP binds to the positively charged surface but no direct electron transfer (DET) is found due to the long distance of the active sites from the electrode surfaces. At carboxyl-terminated surfaces, the neutrally charged bottom of HTHP can bind to the SAM. For this "disc" orientation all six hemes are close to the electrode and their direct electron transfer should be efficient. HTHP on all negatively charged SAMs showed a quasi-reversible redox behavior with rate constant k(s) values between 0.93 and 2.86 s(-1) and apparent formal potentials E-app(0)' between -131.1 and -249.1 mV. On the MUA/MU-modified electrode, the maximum surface concentration corresponds to a complete monolayer of the hexameric HTHP in the disc orientation. HTHP electrostatically immobilized on negatively charged SAMs shows electrocatalysis of peroxide reduction and enzymatic oxidation of NADH.
For the first time a molecularly imprinted polymer (MIP) with direct electron transfer (DET) and bioelectrocatalytic activity of the target protein is presented. Thin films of MIPs for the recognition of a hexameric tyrosine-coordinated heme protein (HTHP) have been prepared by electropolymerization of scopoletin after oriented assembly of HTHP on a self-assembled monolayer (SAM) of mercaptoundecanoic acid (MUA) on gold electrodes. Cavities which should resemble the shape and size of HTHP were formed by template removal. Rebinding of the target protein sums up the recognition by non-covalent interactions between the protein and the MIP with the electrostatic attraction of the protein by the SAM. HTHP bound to the MIP exhibits quasi-reversible DET which is reflected by a pair of well pronounced redox peaks in the cyclic voltammograms (CVs) with a formal potential of −184.4 ± 13.7 mV vs. Ag/AgCl (1 M KCl) at pH 8.0 and it was able to catalyze the cathodic reduction of peroxide. At saturation the MIP films show a 12-fold higher electroactive surface concentration of HTHP than the non-imprinted polymer (NIP).
For the first time a molecularly imprinted polymer (MIP) with direct electron transfer (DET) and bioelectrocatalytic activity of the target protein is presented. Thin films of MIPs for the recognition of a hexameric tyrosine-coordinated heme protein (HTHP) have been prepared by electropolymerization of scopoletin after oriented assembly of HTHP on a self-assembled monolayer (SAM) of mercaptoundecanoic acid (MUA) on gold electrodes. Cavities which should resemble the shape and size of HTHP were formed by template removal. Rebinding of the target protein sums up the recognition by non-covalent interactions between the protein and the MIP with the electrostatic attraction of the protein by the SAM. HTHP bound to the MIP exhibits quasi-reversible DET which is reflected by a pair of well pronounced redox peaks in the cyclic voltammograms (CVs) with a formal potential of -184.4 +/- 13.7 mV vs. Ag/AgCl (1 M KCl) at pH 8.0 and it was able to catalyze the cathodic reduction of peroxide. At saturation the MIP films show a 12-fold higher electroactive surface concentration of HTHP than the non-imprinted polymer (NIP).
Natürliche Evolution hat geschaffenBiopolymereauf der Basis von Aminosäuren undNukleotidezeigt hohe chemische Selektivität und katalytische Kraft. Die molekulare Erkennung durch Antikörper und die katalytische Umwandlung der Substratmoleküle durch Enzyme findet in sogenannten Paratopen oder katalytischen Zentren des Makromoleküls statt, die typischerweise 10-15 Aminosäuren umfassen. Die konzertierte Wechselwirkung zwischen den Reaktionspartnern führt zu Affinitäten bis zu nanomolaren Konzentrationen für die Antigenbindung und nähert sich einer Million Umsätze pro Sekunde anEnzym-katalysierte Reaktionen.
Biosensors representing the technological counterpart of living senses have found routine application in amperometric enzyme electrodes for decentralized blood glucose measurement, interaction analysis by surface plasmon resonance in drug development, and to some extent DNA chips for expression analysis and enzyme polymorphisms. These technologies have already reached a highly advanced level and need minor improvement at most. The dream of the "100-dollar' personal genome may come true in the next few years provided that the technological hurdles of nanopore technology or of polymerase-based single molecule sequencing can be overcome. Tailor-made recognition elements for biosensors including membrane-bound enzymes and receptors will be prepared by cell-free protein synthesis. As alternatives for biological recognition elements, molecularly imprinted polymers (MIPs) have been created. They have the potential to substitute antibodies in biosensors and biochips for the measurement of low-molecular-weight substances, proteins, viruses, and living cells. They are more stable than proteins and can be produced in large amounts by chemical synthesis. Integration of nanomaterials, especially of graphene, could lead to new miniaturized biosensors with high sensitivity and ultrafast response. In the future individual therapy will include genetic profiling of isoenzymes and polymorphic forms of drug-metabolizing enzymes especially of the cytochrome P450 family. For defining the pharmacokinetics including the clearance of a given genotype enzyme electrodes will be a useful tool. For decentralized online patient control or the integration into everyday "consumables' such as drinking water, foods, hygienic articles, clothing, or for control of air conditioners in buildings and cars and swimming pools, a new generation of "autonomous' biosensors will emerge.
Electrochemical synthesis and signal generation dominate among the almost 1200 articles published annually on protein-imprinted polymers. Such polymers can be easily prepared directly on the electrode surface, and the polymer thickness can be precisely adjusted to the size of the target to enable its free exchange. In this architecture, the molecularly imprinted polymer (MIP) layer represents only one ‘separation plate’; thus, the selectivity does not reach the values of ‘bulk’ measurements. The binding of target proteins can be detected straightforwardly by their modulating effect on the diffusional permeability of a redox marker through the thin MIP films. However, this generates an ‘overall apparent’ signal, which may include nonspecific interactions in the polymer layer and at the electrode surface. Certain targets, such as enzymes or redox active proteins, enables a more specific direct quantification of their binding to MIPs by in situ determination of the enzyme activity or direct electron transfer, respectively.
A nanohybrid consisting of poly(3-aminobenzenesulfonic acid-co-aniline) and multiwalled carbon nanotubes [MWCNT-P(ABS-A)]) on a gold electrode was used to immobilize the hexameric tyrosine-coordinated heme protein (HTHP). The enzyme showed direct electron transfer between the heme group of the protein and the nanostructured surface. Desorption of the noncovalently bound heme from the protein could be excluded by control measurements with adsorbed hemin on aminohexanthiol-modified electrodes. The nanostructuring and the optimised charge characteristics resulted in a higher protein coverage as compared with MUA/MU modified electrodes. The adsorbed enzyme shows catalytic activity for the cathodic H2O2 reduction and oxidation of NADH.
The first molecularly imprinted polymer (MIP) for the recognition of the copper-enzyme laccase was successfully prepared by electropolymerizing scopoletin in the presence of alkaline-inactivated enzyme. Laccase-MIP and the control polymer without laccase (nonimprinted polymer, NIP) were characterized by voltammetry using the redox marker ferricyanide. After electropolymerization, the signals for ferricyanide for both the MIP and the NIP were almost completely suppressed and increased after removal of the target from the polymer layer. Rebinding of both inactivated and active laccase decreased the ferricyanide peak currents to almost equal extent. The relative decrease of signal suppression approached saturation above 10 nM. Furthermore, the surface activity of rebound laccase toward the oxidation of catechol was investigated. The surface activity approached saturation above 10 nM, a value close to the value of the measurements with ferricyanide. Interaction of NIP with laccase brought about a six times smaller signal of catechol oxidation.