Information regarding the spatial distribution of soil water content is key in many disciplines and applications including soil and atmospheric sciences, hydrology, and agricultural engineering.
Thus, within the past decades various experimental methods and strategies have been developed to map spatial variations in soil moisture distribution and to monitor temporal changes.
Our study examines the combination of electrical resistivity mapping and point observations of soil moisture to infer the spatial and the temporal variability of soil moisture.
Over a period of around two years, we performed field measurements on six days to collect repeated electrical resistivity mapping data for a nine-hectare test site south-east of Berlin, Germany.
Permanently installed TDR probes, temporary TDR measurements within permanently installed tubes, and gravimetric measurements using soil samples provided soil moisture data at various selected points.
In addition, soil analysis and classification results are available for 132 regularly distributed positions up to depths of 1.2 m.
We compare and link three-dimensional resistivity models obtained via data inversion to soil composition and soil moisture as provided by our point data.
Both the soil samples and the resistivity models indicate a two-layer medium characterized by a sandy top layer with varying thickness and a loamy bottom soil.
For all six field campaigns, we observe similar resistivity patterns reflecting the temporally stable influence of soil texture.
While the overall patterns are stable, the range of resistivity values changes with soil moisture. Finally, to estimate spatial models of soil moisture, we link our soil moisture and resistivity data using empirical petrophysical models relying on a second order polynomial function.
We observe a mean prediction error for soil moisture of +/-0.034 m3 & BULL; m? 3 using all observation points while we notice that point-specific models further reduce the error.
Thus, we conclude that our experimental and data analysis strategies represent a reliable approach to establish site-specific models and to estimate three-dimensional moisture distribution including temporal variations.
The identification of buried soil horizons in agricultural landscapes helps to quantify sediment budgets and erosion-related carbon dynamics. High-resolution mapping of buried horizons using conventional soil surveys is destructive and time consuming. Geoelectrical sensors can offer a fast and non-destructive alternative for determining horizon positions and properties. In this paper, we compare the suitability of several geoelectrical methods for measuring the depth to buried horizons (Apb, Ahb and Hab) in the hummocky ground moraine landscape of northeastern Germany. Soil profile descriptions were developed for 269 locations within a 6-ha experimental field "CarboZALF-D". A stepwise linear discriminant analysis (LDA) estimated the lateral position of the buried horizons using electromagnetic induction data and terrain attributes. To predict the depth of a buried horizon, multiple linear regression (MLR) was used for both a 120-m transect and a 0.2-ha pseudo-three-dimensional (3D) area. At these scales, apparent electrical conductivity (ECa), electrical resistivity (ER) and terrain attributes were used as independent variables. The LDA accurately predicted Apb- and Ahb-horizons (a correct classification of 93%). The LDA of the Hab-horizon had a misclassification of 24%, which was probably related to the smaller test set and the higher depth of this horizon. The MLR predicted the depth of the Apb-, Ahb- and Hab-horizons with relative root mean square errors (RMSEs) of 7, 3 and 13%, respectively, in the pseudo-3D area. MLR had a lower accuracy for the 2D transect compared to the pseudo-3D area. Overall, the use of LDA and MLR has been an efficient methodological approach for predicting buried horizon positions. Highlights The suitability of geoelectrical measurements for digital modelling of diagnostic buried soil horizons was determined. LDA and MLR were used to detect multiple horizons with geoelectrical devices and terrain attributes. Geoelectrical variables were significant predictors of the position of the target soil horizons. The use of these tested digital technologies gives an opportunity to develop high-resolution soil mapping procedures.
In der vorliegenden Arbeit werden verschiedene Experimente zur Untersuchung der elektrischen Leitfähigkeit von Sutur- und Kollisionszonen im Zusammenhang diskutiert, um die Möglichkeiten, die die moderne Magnetotellurik (MT) für das Abbilden fossiler tektonischer Systeme bietet, aufzuzeigen. Aus den neuen hochauflösenden Abbildern der elektrischen Leitfähigkeit können potentielle Gemeinsamkeiten verschiedener tektonischer Einheiten abgeleitet werden. Innerhalb der letzten Dekade haben sich durch die Weiterentwicklung der Messgeräte und der Auswerte- und Interpretationsmethoden völlig neue Perspektiven für die geodynamische Tiefensondierung ergeben. Dies wird an meinen Forschungsarbeiten deutlich, die ich im Rahmen von Projekten selbst eingeworben und am Deutschen GeoForschungsZentrum Potsdam durchgeführt habe. In Tabelle A habe ich die in dieser Arbeit berücksichtigten Experimente aufgeführt, die in den letzten Jahren entweder als Array- oder als Profilmessungen durchgeführt wurden. Für derart große Feldexperimente benötigt man ein Team von WissenschaftlerInnen, StudentInnen und technischem Personal. Das bedeutet aber auch, dass von mir betreute StudentInnen und DoktorandInnen Teilaspekte dieser Experimente in Form von Diplom-, Bachelor- und Mastersarbeiten oder Promotionsschriften verarbeitet haben. Bei anschließender Veröffentlichung der Arbeiten habe ich als Co-Autor mitgewirkt. Die beiliegenden Veröffentlichungen enthalten eine Einführung in die Methode der Magnetotellurik und gegebenenfalls die Beschreibung neu entwickelter Methoden. Eine allgemeine Darstellung der theoretischen Grundlagen der Magnetotellurik findet man zum Beispiel in Chave & Jones (2012); Simpson & Bahr (2005); Kaufman & Keller (1981); Nabighian (1987); Weaver (1994). Die Arbeit beinhaltet zudem ein Glossar, in dem einige Begriffe und Abkürzungen erklärt werden. Ich habe mich entschieden, Begriffe, für die es keine adäquate deutsche Übersetzung gibt oder die im Deutschen eine andere oder missverständliche Bedeutung bekommen, auf Englisch in der Arbeit zu belassen. Sie sind durch eine kursive Schreibweise gekennzeichnet.
Combined structural and magnetotelluric investigation across the West Fault Zone in northern Chile
(2002)
The characterisation of the internal architecture of large-scale fault zones is usually restricted to the outcrop-based investigation of fault-related structural damage on the Earth's surface. A method to obtain information on the downward continuation of a fault is to image the subsurface electrical conductivity structure. This work deals with such a combined investigation of a segment of the West Fault, which itself is a part of the more than 2000 km long trench-linked Precordilleran Fault System in the northern Chilean Andes. Activity on the fault system lasted from Eocene to Quaternary times. In the working area (22°04'S, 68°53'W), the West Fault exhibits a clearly defined surface trace with a constant strike over many tens of kilometers. Outcrop condition and morphology of the study area allow ideally for a combination of structural geology investigation and magnetotelluric (MT) / geomagnetic depth sounding (GDS) experiments. The aim was to achieve an understanding of the correlation of the two methods and to obtain a comprehensive view of the West Fault's internal architecture. Fault-related brittle damage elements (minor faults and slip-surfaces with or without striation) record prevalent strike-slip deformation on subvertically oriented shear planes. Dextral and sinistral slip events occurred within the fault zone and indicate reactivation of the fault system. Youngest deformation increments mapped in the working area are extensional and the findings suggest a different orientation of the extension axes on either side of the fault. Damage element density increases with approach to the fault trace and marks an approximately 1000 m wide damage zone around the fault. A region of profound alteration and comminution of rocks, about 400 m wide, is centered in the damage zone. Damage elements in this central part are predominantly dipping steeply towards the east (70-80°). Within the same study area, the electrical conductivity image of the subsurface was measured along a 4 km long MT/GDS profile. This main profile trends perpendicular to the West Fault trace. The MT stations of the central 2 km were 100 m apart from each other. A second profile with 300 m site spacing and 9 recording sites crosses the fault a few kilometers away from the main study area. Data were recorded in the frequency range from 1000 Hz to 0.001 Hz with four real time instruments S.P.A.M. MkIII. The GDS data reveal the fault zone for both profiles at frequencies above 1 Hz. Induction arrows indicate a zone of enhanced conductivity several hundred meters wide, that aligns along the WF strike and lies mainly on the eastern side of the surface trace. A dimensionality analysis of the MT data justifies a two dimensional model approximation of the data for the frequency range from 1000 Hz to 0.1 Hz. For this frequency range a regional geoelectric strike parallel to the West Fault trace could be recovered. The data subset allows for a resolution of the conductivity structure of the uppermost crust down to at least 5 km. Modelling of the MT data is based on an inversion algorithm developed by Mackie et al. (1997). The features of the resulting resistivity models are tested for their robustness using empirical sensitivity studies. This involves variation of the properties (geometry, conductivity) of the anomalies, the subsequent calculation of forward or constrained inversion models and check for consistency of the obtained model results with the data. A fault zone conductor is resolved on both MT profiles. The zones of enhanced conductivity are located to the east of the West Fault surface trace. On the dense MT profile, the conductive zone is confined to a width of about 300 m and the anomaly exhibits a steep dip towards the east (about 70°). Modelling implies that the conductivity increase reaches to a depth of at least 1100 m and indicates a depth extent of less than 2000 m. Further conductive features are imaged but their geometry is less well constrained. The fault zone conductors of both MT profiles coincide in position with the alteration zone. For the dense profile, the dip of the conductive anomaly and the dip of the damage elements of the central part of the fault zone correlate. This suggests that the electrical conductivity enhancement is causally related to a mesh of minor faults and fractures, which is a likely pathway for fluids. The interconnected rock-porosity that is necessary to explain the observed conductivity enhancement by means of fluids is estimated on the basis of the salinity of several ground water samples (Archie's Law). The deeper the source of the water sample, the more saline it is due to longer exposure to fluid-rock interaction and the lower is the fluid's resistivity. A rock porosity in the range of 0.8% - 4% would be required at a depth of 200 m. That indicates that fluids penetrating the damaged fault zone from close to the surface are sufficient to explain the conductivity anomalies. This is as well supported by the preserved geochemical signature of rock samples in the alteration zone. Late stage alteration processes were active in a low temperature regime (<95°C) and the involvement of ascending brines from greater depth is not indicated. The limited depth extent of the fault zone conductors is a likely result of sealing and cementation of the fault fracture mesh due to dissolution and precipitation of minerals at greater depth and increased temperature. Comparison of the results of the apparently inactive West Fault with published studies on the electrical conductivity structure of the currently active San Andreas Fault, suggests that the depth extent and conductivity of the fault zone conductor may be correlated to fault activity. Ongoing deformation will keep the fault/fracture mesh permeable for fluids and impede cementation and sealing of fluid pathways.