Refine
Has Fulltext
- no (39) (remove)
Year of publication
- 2014 (39) (remove)
Document Type
- Article (21)
- Conference Proceeding (16)
- Preprint (1)
- Review (1)
Is part of the Bibliography
- yes (39)
Keywords
- cardiopulmonary exercise testing (2)
- hypertension (2)
- Aging (1)
- Bimanual probe (1)
- Biochemical profiles (1)
- DDP-4 inhibition (1)
- Doping tests (1)
- Dual-task walking (1)
- ECG (1)
- Error monitoring (1)
Institute
- Department Sport- und Gesundheitswissenschaften (39) (remove)
Flexion-extension ratio of trunk peak torque measures and antagonistic activity in males and females
(2014)
Purpose: Mirror therapy can improve motor and sensory functions, but effects of the mirror illusion on primary motor and somatosensory cortex could not be established consistently.
Methods: Fifteen right handed healthy volunteers performed or observed a finger-thumb opposition task. Cerebral activations during normal movement (NOR), mirrored movement (MIR) and movement observation (OBS) by means of a video chain were recorded with functional magnetic resonance imaging (fMRI). Activation sizes in movement > static conditions were identified using SPM8 (p < 0.001, unc.) and attributed to predefined areas employing the Anatomy toolbox 1.8. Laterality indices for the responsive areas were calculated on the basis of the number of activated voxels.
Results: Relevant bilateral BOLD responses were found in primary motor (M1) and somatosensory (S1 - BA 2, 3b and 3a) cortex, premotor and parietal areas and V5. When comparing MIR to NOR, no significant change of contralateral activation in M1 was found, but clearly at S1 with differences between hands.
Conclusion: The mirror illusion does not elicit immediate changes in motor areas, yet there is a direct effect on somatosensory areas, especially for left hand movements. These results suggest different effects of mirror therapy on processing and rehabilitation of motor and sensory function.
Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation.
Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm.
Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.
Reliability of ultrasound measurements for subcutaneous adipose tissue in elite canoe athletes
(2014)
We sought to investigate the effects of wearing a mobile respiratory gas analysis system during a treadmill test on blood lactate (bLa) concentrations and commonly applied bLa thresholds. A total of 16 recreational athletes (31 +/- 3 years, V0205: 58 6 ml min(-1)-kg(-1)) performed one multistage treadmill test with and one without gas exchange measurements (GEM and noGEM). The whole bLa curve, the lactate threshold (LT), the individual anaerobic thresholds according to Stegmann(IAT(sr)) and Dickhuth (IAT(Di)), and a fixed bLa concentration of 4 mmob.l(-1) (OBLA) were evaluated. The bLa curve was shifted slightly leftward in GEM compared to noGEM (P<0.05), whereas the heart rate response was not different between conditions (P= 0.89). There was no difference between GEM and noGEM for LT (2.61 +/- 0.34 vs. 2.64 +/- 0.39 m(-1) s(-1) P=0.49) and IAT(st) (3.47 +/- 0.42 vs. 3.55 +/- 0.47m-s(-1), P=0.12). However, IATD(Di) (3.57 +/- 0.39 vs. 3.66 +/- 0.44m-s(-1), P<0.01) and OBLA (3.85 +/- 0.46 vs. 3.96 +/- 0.47m-s-1, P<0.01) occurred at slower running velocities in GEM. The bLa response to treadmill tests is mildly affected by wearing a mobile gas analysis system. This also applies to bLa thresholds located at higher exercise intensities. While the magnitude of the effects is of little importance for recreational athletes, it might be relevant for elite athletes and scientific studies.