Background: Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC).
Methods: The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP).
Results: Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r2 = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison.
Conclusions: With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.
Fast and easy tests for quantifying fat-soluble vitamins such as vitamin E and vitamin A, as well as beta-carotene, in whole blood without a need to preprocess blood samples could facilitate assessment of the vitamin status of dairy cattle. The objective of this study was to validate a field-portable fluorometer/spectrophotometer assay for the rapid quantification of these vitamins in whole blood and plasma of dairy cows and calves. We measured the concentrations of vitamin E and beta-carotene in whole blood and plasma from 28 dairy cows and 11 calves using the iCheck test (Bio-Analyt GmbH, Teltow, Germany) and compared the results with the current analytical standard (HPLC) in 2 independent laboratories, one at the University of Potsdam (Germany) and at one at DSM Nutritional Products Ltd. (Kaiseraugst, Switzerland). For vitamin A, the HPLC measurements were done only in the laboratory in Germany. The whole-blood concentrations of vitamin E as determined by iCheck (blood-hematocritcorrected) ranged from 1.82 to 4.99 mg/L in dairy cows and 0.34 to 3.40 mg/L in calves. These findings were moderately correlated (R-2 = 0.66) with the values assessed by HPLC in dairy cattle (cows + calves). When calves were excluded, the correlation was higher (R-2 = 0.961). The beta-carotene and vitamin A values obtained by the reference method HPLC were highly correlated with the iCheck methods in whole blood (R-2 = 0.99 and 0.88, respectively). In plasma, we observed strong correlations between the concentrations assessed by iCheck and those of HPLC for vitamin E (R-2 = 0.97), beta-carotene (R-2 = 0.98), and vitamin A (R-2 = 0.92) in dairy cattle (cows + calves). For vitamin E, beta-carotene, and vitamin A, we compared the relationship between the differences obtained by the iCheck assay and the HPLC measurements, as well as the magnitude of measurements, using Bland-Altman plots to test for systematic bias. For all 3 vitamins, the differences values were not outside the 95% acceptability limits; we found no systematic error between the 2 methods for all 3 analytes.