Refine
Has Fulltext
- no (140)
Year of publication
Document Type
- Article (138)
- Monograph/Edited Volume (2)
Language
- English (140) (remove)
Is part of the Bibliography
- yes (140)
Keywords
- Detector modelling and simulations II (electric fields, charge transport, multiplication and induction, pulse formation, electron emission, etc) (1)
- Energy-dispersive Laue diffraction (1)
- Interaction of radiation with matter (1)
- Solid state detectors (1)
- X-ray imaging (1)
- X-ray spectroscopy (1)
- pnCCD (1)
Institute
The possibilities and limits of structure refinement of Langmuir-Blodgett films by means of symmetrical reflection of X- rays are described using the example of a stearic acid multilayer. Three different techniques for the determiantion of the electron density profile from reflectivity data are compared; a Fourier method, a Patterson method, and model calculations. The important role of the a priori information for finding the besft structure model is outlined.
Experiments using a simple X-ray interferometer to measure the degree of spatial coherence of hard X-rays are reported. A monolithic Fresnel bimirror is used at small incidence angles to investigate synchrotron radiation in the energy interval 5-50 keV with monochromatic and white beam. The experimental setup was equivalent to a Young's double-slit experiment for hard X-rays with slit dimensions in the micrometre range. From the high-contrast interference pattern the degree of coherence was determined.
A crystal of hen egg-white lysozyme was analyzed by means of energy-dispersive X-ray Laue diffraction with white synchrotron radiation at 2.7 angstrom resolution using a pnCCD detector. From Laue spots measured in a single exposure of the arbitrarily oriented crystal, the lattice constants of the tetragonal unit cell could be extracted with an accuracy of about 2.5%. Scanning across the sample surface, Laue images with split reflections were recorded at various positions. The corresponding diffraction patterns were generated by two crystalline domains with a tilt of about 1 degrees relative to each other. The obtained results demonstrate the potential of the pnCCD for fast X-ray screening of crystals of macromolecules or proteins prior to conventional X-ray structure analysis. The described experiment can be automatized to quantitatively characterize imperfect single crystals or polycrystals.
The first application of a pnCCD detector for X-ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two-dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse-resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution Delta E/E similar or equal to 10(-2). a three-dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so-called single-photon- counting mode. A full dataset was evaluated taking into account all photons recorded within 10(5) detector frames at a readout rate of 200 Hz. By representing the data in reciprocal-space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.